PRESENTATION OF THE APPLIANCE Lacunza congratulates you on your choice. Certified under ISO 9001, Lacunza guarantees the quality of its appliances and undertakes to meet the needs of its customers. Confident of the know-how afforded by more than 50 years’ experience, Lacunza uses advanced technologies in the design and manufacture of its entire range of appliances.
Page 3
PRESENTATION OF THE APPLIANCE 3.7.2. Removing the Izaro 60 CLI deflectors........................29 3.7.3. Removing the Izaro 60 CLI vermiculite back plates and bases................31 3.8. Opening the door ............................32 3.8.1. Opening using the guillotine system: ........................32 3.8.2.
PRESENTATION OF THE APPLIANCE PRESENTATION OF THE APPLIANCE For optimum operation of the appliance, we advise you to read this manual carefully before switching on the appliance for the first time. In case of problems or concerns, we urge you to contact your dealer, who will cooperate with you.
Page 5
Instruction Book. Failure to respect these conditions may lead to problems with the appliance (deterioration, shorter useful life, etc.) which are not covered by the Lacunza warranty.
Page 6
PRESENTATION OF THE APPLIANCE Figure No.1 - Dimensions of the Izaro 60/STAR CLI appliance in mm...
Page 7
PRESENTATION OF THE APPLIANCE Figure No.2 - Dimensions of the Izaro 60/STAR CLD appliance in mm...
PRESENTATION OF THE APPLIANCE 1.2. Safety distances Be sure to respect the appliance installation distances from combustible materials. NOTE: Images with safety distances from Izaro 80-100 CLI. For the Izaro 80-100 CLD model (Side Glass on the Right side), the distances would be the same, but considering that the placement of the appliance would be on the opposite side to this one shown for the Izaro 80- 100 CLI.
(kW) grilles (cm fixtures, etc.). P ≤ 10kW Lacunza’s liability is limited to the supply 10 < P ≤ 15 of the material and does not include 15 < P ≤ 20 installation of the appliance.
INSTRUCTIONS FOR THE INSTALLER necessary to install a non-closable outside- of them under the front leg and the air inlet with a section of at least 90 cm². other, on the opposite side diagonally under the hind leg (see image below), so 2.2.2.
INSTRUCTIONS FOR THE INSTALLER friction or noise other than that of correct operation of the guillotine system. 2.3.4. Casing Make sure that the material around the appliance is not flammable or likely to deteriorate as a result of heat (wallpaper, carpet, plastic-based casing, Silestone, etc.).
(12 meters) for each accessory used. appliance is fitted. This would be the best option, since in non-central-heating appliances this way there would be no drafts inside the (without back boiler), Lacunza does not cabin in which the device is installed or a...
INSTRUCTIONS FOR THE INSTALLER lack of oxygen. It also has the advantage Ø120mm on the top shell of the appliance. that if a mechanical air extraction or Pipes can be fitted from these outlets to ventilation device is being used in the same other rooms.
INSTRUCTIONS FOR THE INSTALLER Note: The values shown in the above table were measured at the appliance output point and based on tests performed at nominal heat output and maximum fan speed. All hot-air ducts lose heat, meaning that the heat output obtained at the end of piping always depends on its design.
Page 15
INSTRUCTIONS FOR THE INSTALLER Figure No.13 - Image showing Option C Figure No.12 - Image showing Option B OPTION D: Combustion-air intake from outside the room and hot-air output by OPTION C: Combustion-air intake from forced convection (with fan). outside the room and hot-air output by natural convection (without fan).
INSTRUCTIONS FOR THE INSTALLER WARNING! When the appliance has a 2.3.9. Exterior Frame. Removal and fan (C/V option), it is important that the assembly casing is well ventilated through both the If you need to remove the exterior frame upper and lower grilles on the casing. from the appliance (casing, transportation, Respect minimum...
INSTRUCTIONS FOR THE INSTALLER 2.3.10. Fan and probe-air regulator ATTENTION! The 3-wire power hoses for connection (only for models C/V) the power supply 230V is not supplied and must be connected by a person qualified to IZARO c/v models (the models with fans) install it.
Page 18
INSTRUCTIONS FOR THE INSTALLER Figure No.18 - Connections to be made in the controller and the power module of the Izaro C/V...
Page 19
INSTRUCTIONS FOR THE INSTALLER ATTENTION!, power module, housed in a metal container of dimensions 150x107x64 mm with fixing fins, must be housed in a cold place, where the temperature never exceeds 50 C. If it is placed inside the cladding, it should always go as close as possible to the vents of the cladding itself to ensure that it is in the coldest place possible.
The flue must be clean and airtight over WARNING: the operating temperature its entire length. of the potentiometer supplied by Lacunza The flue must be at least 6m tall and the on IZARO C/V models (with fan) is from 0...
INSTRUCTIONS FOR THE INSTALLER is essential that insulation be enhanced in sections in which combustible material is present (wooden beams, furniture, etc.). It may even be necessary to protect non- combustible material in order to prevent breakage, deformation, etc., as a result of overheating if the material is not designed to withstand high temperatures.
Page 22
INSTRUCTIONS FOR THE INSTALLER Figure No.25 - Distances between the chimney crown and objects within a radius of between 10 and 20m...
INSTRUCTIONS OF USE • Resinous wood may mean that the INSTRUCTIONS OF USE appliance and the flue need to be cleaned more often. The manufacturer accepts no liability whatsoever for damage caused to parts as Non-permitted fuels: a result of the improper use of non- •...
INSTRUCTIONS OF USE 3.2. Description of the parts of the appliance 3.2.1. IZARO 60 CLI Operating components...
Page 25
INSTRUCTIONS OF USE Figure No.27 - Operating components on the IZARO 60 CLI appliance...
Page 26
INSTRUCTIONS OF USE • A: Firebox door handle • B: Single lever register, combustion air inlet control B1 open (turn counterclockwise) - Primary air inlet open (during ignition) - Secondary air inlet open (glass cleaning) - Double open combustion air inlet. B2 Operating position at nominal heating power - Primary air inlet closed.
INSTRUCTIONS OF USE 3.3. Lighting Use of the appliance in warm weather (warm days, early hours of the afternoon on sunny days) may lead to lighting and updraught problems. Certain weather conditions, such as fog, ice, humidity entering the flue, etc., may hinder sufficient updraught in the flue and lead to suffocation.
INSTRUCTIONS OF USE • Distribute the embers throughout 3.5. Operation the fire base evenly. The appliance should be operated with • Place 1 or 2 logs on the embers. By the door closed. stacking the logs loosely, the firewood burns much faster, since oxygen can reach For safety reasons, never close all the all parts of the wood.
INSTRUCTIONS OF USE In class B or BE appliances (without 3.6. Removing ash combustion air ducting from the street), Following sustained when the appliance is not in use, the appliance, it is necessary to remove the ash appliance-flue duct assembly from the firebox.
INSTRUCTIONS OF USE 3.7.2. Removing the Izaro 60 CLI 3.7. Removable interior deflectors. components. Deflectors. Vermiculite firebox plates. The appliance has 3 rows of removable vermiculite deflectors, which are placed in NOTE: explanation this way. In the case of the Izaro STAR, it also disassembly of the interior components of has a catalyst located between the lower the home will be carried out for the IZARO...
Page 31
INSTRUCTIONS OF USE Next, remove the 2 lower deflectors. Figure No.33 - Removing the lower deflector Left (side glass side) Start with the lower deflector, which is on the opposite side of the side window. Move it horizontally towards the front with a Now remove the middle deflector, slight upward tilt until it is released from the turning it from its rear upwards, and then...
INSTRUCTIONS OF USE Figure No.35 - Removing the Izaro 60 CLI upper c- Remove the central rear base (10) by deflector bringing it forward. Soot can accumulate in the deflector, which falls from the flue. NOTE: The disassembly of the deflectors in the CLD model (Right Side Glass) would be the same as in the CLI model that has been explained, but taking into account that...
INSTRUCTIONS OF USE 3.8. Opening the door The door can be opened in 2 ways: 3.8.1. Opening using the guillotine system: This system, in which the door opens vertically, is the usual way to open and close the firebox in order to load and rearrange the firewood when the appliance is in normal use.
Page 34
With the door closed (make sure the door is completely down), we will insert the levers manipulation tool supplied by Lacunza into the rotating lever located in the upper-right part of the door. Insert it completely until we notice that it stopsmit.
INSTRUCTIONS OF USE Figure No.40 - Open the door handle outwards Figure No.39 - Turn the upper-left lever clockwise 90 • 3rd Lever Turn: it is the designated lever “E” in section “3.2.1. Operating elements”. We turn this third lever, located on the lower side of the device, counterclockwise.
INSTRUCTIONS OF USE 3.9.2. Automatic / manual air regulator operation: • Operation: when powered, the device shows the Stand-by light point on. The controller is equipped with an automatic function and a manual function . It is activated by pressing key, thus switching to automatic mode.
Page 37
INSTRUCTIONS OF USE º Figure No.43 - Itaca air regulator automatic/manual display For more information, see the ELX AIR POWER air regulator instruction manual. The remote control of some TV brands may interfere with the potentiometer sensor and change its operation. To avoid possible interference, it is recommended to place the potentiometer in a place away from the TV.
MAINTENANCE AND IMPORTANT ADVICE Attention, never let the product drip MAINTENANCE AND into the lower part of the glass. The IMPORTANT ADVICE accumulation of the cleaning product, with soot or ash residues, can damage the screen printing on the glass. 4.1.
Lacunza recommends that only Lacunza- the vermiculite base and bottom pieces. authorised replacement parts be used. Lacunza accepts no liability for any modification to the product which it has not authorised. This appliance is a heat-producing appliance and contact may lead to burns.
TROUBLESHOOTING TROUBLESHOOTING This symbol means that a qualified professional should be called to perform the operation. Problem Probable causes Solution Use hard woods, cut at least 2 years ago and stored in a Green or damp wood sheltered, ventilated place Use crumpled paper or firelighters and dry wood chips to light The logs are too large the fire.
RECYCLING DE PRODUCT RECYCLING DE PRODUCT The recycling of the appliance is the exclusive responsibility of the owner, who must act in compliance with the laws in force in his country regarding safety, respect and protection of the environment. At the end of its useful life, the product must not be disposed of with urban waste. It can be delivered to the specific selective collection centers set up by the municipalities, or to retailers who offer this service.
Need help?
Do you have a question about the Izaro 60-STAR CLI-CLD C and is the answer not in the manual?
Questions and answers