Gigabyte R283-Z98-AAL1 User Manual
Gigabyte R283-Z98-AAL1 User Manual

Gigabyte R283-Z98-AAL1 User Manual

Rack server-amd epyc 9005/9004 2u dp 16-bay e3.s gen5 nvme + 4 x e3.s cxl module
Table of Contents

Advertisement

Quick Links

R283-Z98-AAL1
Rack Server - AMD EPYC™ 9005/9004
2U DP 16-Bay E3.S Gen5 NVMe + 4 x E3.S CXL module
User Manual
Rev. 3.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R283-Z98-AAL1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gigabyte R283-Z98-AAL1

  • Page 1 R283-Z98-AAL1 Rack Server - AMD EPYC™ 9005/9004 2U DP 16-Bay E3.S Gen5 NVMe + 4 x E3.S CXL module User Manual Rev. 3.0...
  • Page 2 GIGABYTE's prior written permission. Documentation Classifications In order to assist in the use of this product, GIGABYTE provides the following types of documentation:  User Manual: detailed information & steps about the installation, configuration and use of this product (e.g.
  • Page 3 Conventions The following conventions are used in this user's guide: NOTE! Pieces of additional information related to the current topic. CAUTION! Precautionary measures to avoid possible hardware or software problems. WARNING! Alerts to any damage that might result from doing or not doing specific actions.
  • Page 4: Server Warnings And Cautions

    Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
  • Page 5 CAUTION! • Do not operate the server for long periods with the access panel open or removed. Operat- ing the server in this manner results in improper airflow and improper cooling that can lead to thermal damage. • Danger of explosion if battery is incorrectly replaced. •...
  • Page 6: Electrostatic Discharge (Esd)

    Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
  • Page 7 Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that can be gripped with fin-gertips or with a pair of fine needle nosed pliers. If the jumpers do not have such a tab, take care when us- ing needle nosed pliers to remove or install a jumper;...
  • Page 8: Table Of Contents

    Table of Contents Chapter 1 Hardware Installation ................... 11 Installation Precautions .................. 11 Product Specifications ..................12 System Block Diagram ................... 15 Chapter 2 System Appearance ..................16 Front View ...................... 16 Rear View ....................... 17 Front Panel LEDs and Buttons ............... 18 RoT LEDs .......................
  • Page 9 G-SC Module ....................50 4-3-1 CDCR114 .......................50 Backplane Board Storage Connector ............51 4-4-1 CBP20P0 ........................51 4-4-2 CBP2025 (Rear System Storage Board) ..............52 Chapter 5 BIOS Setup ....................53 The Main Menu ....................55 Advanced Menu ..................... 58 5-2-1 CPU Configuration ....................59 5-2-2 NVMe Configuration ....................60 5-2-3...
  • Page 10 5-5-1 North Bridge ......................150 Server Management Menu ................151 5-6-1 System Event Log ....................153 5-6-2 View FRU Information ..................154 5-6-3 BMC VLAN Configuration ..................155 5-6-4 BMC Network Configuration .................156 5-6-5 IPv6 BMC Network Configuration .................157 Security Menu ....................158 5-7-1 Secure Boot ......................159 Boot Menu ....................
  • Page 11: Chapter 1 Hardware Installation

    Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the service guide and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
  • Page 12: Product Specifications

    Product Specifications NOTE: We reserve the right to make any changes to the product specifications and product-related information without prior notice. System Security Server Socket Operating Properties Š 2U Dimension Š 438 (W) x 87.5 (H) x 815(D) mm System fan Power Supply Superchip Š...
  • Page 13 Storage Front hot-swap: Š 16 x E3.S Gen5 NVMe Š (8 x NVMe from CPU_0, 8 x NVMe from CPU_1) Rear hot-swap: Š 4 x 2.5" SATA/SAS-4 Š SATA via CRS2810 from CPU_1 Internal M.2: Š 1 x M.2 (2280/22110), PCIe Gen3 x4, from CPU_0 Š...
  • Page 14 Š 100-240V~ [1] The system power supply requires C19 power cord. [Note] GIGABYTE offers PSUs with various efficiency ratings and power outputs. Full redundancy may depend on your server configuration, and alternative PSU options may be needed. Please contact our sales representatives for the best power solution.
  • Page 15: System Block Diagram

    System Block Diagram NVMe x8 NVMe x8 SATA x4 Occupied by CRS2810 Occupied by CRS2810 16-bay E3.S Gen5 NVMe 4 x SATA ports 4 x SATA ports PCIe3.0 x4 PCIe3.0 x2 PCIe3.0 x4 4-bay 2.5" SATA (rear) 12-Channel DDR5 RDIMM 12-Channel DDR5 RDIMM 12 x DIMM slots 12 x DIMM slots...
  • Page 16: Chapter 2 System Appearance

    Chapter 2 System Appearance Front View Description Front Panel LEDs and Buttons USB 3.2 Gen1 Port x 2 EEDSFF E3.S SSD Bay EDSFF E3.S 2T CXL • Refer to section 2-3 Front Panel LEDs and Buttons for a detailed description of the function of the LEDs.
  • Page 17: Rear View

    Rear View SLOT12 SLOT9 SLOT8 SLOT5 SLOT6 PSU2 PSU1 SLOT2 SLOT1 Description Description Mini DisplayPort Management LAN Port ID LED OCP 3.0 Slot (Option/SFF) USB 3.2 Gen1 Port x 2 PCIe Slot Data LAN Port x 2 2.5” Hard Drive Bay •...
  • Page 18: Front Panel Leds And Buttons

    Front Panel LEDs and Buttons No. Name Color Status Description Reset Button Press this button to reset the system. Press this button for the server to generate a NMI to the NMI button processor. If multiple-bit ECC errors occur, the server will effectively be halted.
  • Page 19: Rot Leds

    RoT LEDs ID LED Status LED LED on Front panel (Note5) ID LED Status LED EC Firmware (FW) Authentication fail or not exit EC FW is broken or not exit (Note1) Authenticating/Recovering BMC/BIOS Images Authenticating Images Blinks Blue Blinks Green Recovering BMC Active Flash 4 times per second 4 times per second...
  • Page 20 Active Flash Authentication (AUTH) Fail Blinks Blue Blinks Green BMC : AUTH Fail (Note2) 1 time per second 1 time per second Blinks Blue Blinks Amber BIOS : AUTH fail (Note2) 1 time per second 1 time per second Blinks Blue Blinks Green 2 times per second 2 times per second...
  • Page 21: Rear System Lan Leds

    Rear System LAN LEDs Name Color Status Description Yellow 1 Gbps data rate 1GbE Speed Green 100 Mbps data rate 10 Mbps data rate Link between system and network or no access Green 1GbE Link / Blink Data transmission or reception is occurring. Activity LED No data transmission or reception is occurring.
  • Page 22: Power Supply Unit Led

    Power Supply Unit LED NOTE! The power supply may be vary based on the system configuration. PSU LED State Description No AC power to all power supplies 1Hz Green Blinking AC present / only standby on / Cold redundant mode 2Hz Green Blinking Power supply firmware updateing mode AC cord unplugged or AC power lost;...
  • Page 23: Hard Disk Drive Leds

    Hard Disk Drive LEDs HDD Present RAID SKU LED #1 Locate Rebuilding HDD Access Fault (No Access) Green ON(*1) BLINK (*2) Disk LED (LED on Back Panel) Amber No RAID configuration Removed HDD Green ON(*1) (via HBA) Slot (LED on Amber Back Panel) Green...
  • Page 24: Chapter 3 System Hardware Installation

    Chapter 3 System Hardware Installation Pre-installation Instructions Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
  • Page 25: Removing And Installing The Chassis Cover

    Removing and Installing the Chassis Cover Before you remove or install the system cover • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the chassis cover: Remove the screw securing the chassis cover. Unlock the plastic handle and pull the grip handle to open the panel cover.
  • Page 26: Installing The Edsff Ssd

    Installing the EDSFF SSD Read the following guidelines before you begin to install or replace the SSD: • Make sure the system is not turned on or connected to AC power. • Take note of the drive tray orientation before sliding it out. •...
  • Page 27: Removing And Installing The Fan Duct

    Removing and Installing the Fan Duct Follow these instructions to remove the fan duct: Lift up to remove the fan duct. To reinstall the fan duct, align the fan duct with the guiding groove. Push down the fan duct until it is firmly seated on the system.
  • Page 28: Removing And Installing The Heat Sink

    Removing and Installing the Heat Sink Read the following guidelines before you begin to install the heat sink: • Always turn off the computer and unplug the power cord from the power outlet before installing the heat sink to prevent hardware damage. •...
  • Page 29: Removing And Installing The Cpu

    Removing and Installing the CPU Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
  • Page 30 • Lock the CPU by using a Torx T20 screwdriver to tighten screw. • When installing the heatsink to CPU, use a Torx T20 screwdriver to tighten 6 captive nuts in sequence as 1-6. • The screw tightening torque: 13.5 ± 0.5 kgf-cm. •...
  • Page 31: Removing And Installing Memory

    Removing and Installing Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. • Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
  • Page 32: Removing And Installing A Memory Module

    3-6-2 Removing and Installing a Memory Module Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR5 DIMMs on to this motherboard.
  • Page 33: Memory Population Table

    3-6-4 Memory Population Table EPYC Memory Speed based on DIMM Population (One DIMM per Channel) DDR5 Frequency MT/s DIMM DIMM 6400 MT/s 5600 MT/s 4800 MT/s Population Type Grade DIMM Grade DIMM Grade DIMM 1R (1 rank) 6400 5600 4800 RDIMM 5600 4800...
  • Page 34: Removing And Installing The Pcie Card

    Removing and Installing the PCIe Card • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered off and all power sources have been disconnected from the server prior to installing a PCIe card.
  • Page 35 System Hardware Installation - 35 -...
  • Page 36: Installing The Mezzanine Card

    Installing the Mezzanine Card 3-8-1 Installing the OCP 3.0 Mezzanine Card Use of the following type of OCP 3.0 NIC is recommended: • OCP 3.0 SFF with pull tab • OCP 3.0 SFF with ejector latch Save the black M3 screws in the event that you need to re-install the cover. Follow these instructions to install an OCP 3.0 Mezzanine card: Remove the two screws securing the OCP 3.0 card slot cover.
  • Page 37: Installing The M.2 Device And Heat Sink

    Installing the M.2 Device and Heat Sink CAUTION The position of the stand-off screw will depend on the size of the M.2 device. The stand-off screw is pre-installed for 22110 cards as standard. Refer to the size of the M.2 device and change the position of the stand-off screw accordingly.
  • Page 38: Replacing The Fan Assembly

    3-10 Replacing the Fan Assembly • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered-down and all power sources have been disconnected from the server prior to replacing a system fan.
  • Page 39: Removing And Installing The Power Supply

    3-11 Removing and Installing the Power Supply Follow these instructions to replace the power supply: Flip up and then grasp the power supply handle. Press the retaining clip on the right side of the power supply unit in the direction indicated. Pull out the power supply unit using the handle.
  • Page 40: Cable Routing

    3-12 Cable Routing CPU0 CPU1 Motherboard: FP_1 Front IO Board: FP_1 Front Panel LEDs and Buttons Cable Front IO Board: FP_1 Motherboard: FUSB_1 Front Panel USB 3 Ports Cable System Hardware Installation - 40 -...
  • Page 41 CPU0 CPU1 Motherboard: BP_ATX1 HDD Backplane Board Power Cable Front HDD Board: ATX1 Motherboard: BP_ATX2 HDD Backplane Board Power Cable Rear HDD Board: BP_2X3 Motherboard: BP_ATX3 HDD Backplane Board Power Cable Rear HDD Board: BP_2X3 Front HDD Board: 12V_IN1 HDD Backplane Board Power Cable Motherboard: 12V_BP1 Front HDD Board: 12V_IN2 HDD Backplane Board Power Cable...
  • Page 42 CPU0 CPU1 Motherboard: BP_1 HDD Backplane Board Signal Cable Front HDD Board: BP_1 Front Right HDD Board: BP_1 HDD Backplane Board Signal Cable Front Left HDD Board: SERIES Rear Right Board: BP_SERIES HDD Backplane Board Signal Cable Rear Left HDD Board: BP_1 System Hardware Installation - 42 -...
  • Page 43 CPU0 CPU1 M.2 Module: SATA_RA4 Rear Right HDD Board: SL_SAS0 SATA Cable M.2 Module: SATA_RA2 Rear Left HDD Board: SL_SAS0 System Hardware Installation - 43 -...
  • Page 44 CPU0 CPU1 P3 P5 P1 OCP2 Motherboard: U2_P0_P0_0 NVMe 0-3 NVMe 8 Front HDD Board: Cable Cable A1: U.2_0/A2: U.2_1 Front HDD Board: U.2_8 A3: U.2_2/A4: U.2_3 Motherboard: U2_P0_P1_0 Motherboard: U2_P0_P0_1 NVMe 4-5 NVMe 10 Front HDD Board: Cable Cable Front HDD Board: U.2_10 B1: U.2_4/B2.
  • Page 45 CPU0 CPU1 P3 P5 P1 Motherboard: U2_P1_P2_1 Motherboard: U2_P1_P3_1 NVMe 14-15 NVMe 18-19 Front HDD Board: Front HDD Board: Cable Cable G1: U.2_14 I1: U.2_4 I2. U.2_5 G2: U.2_15 Motherboard: U2_P1_P3_0 Motherboard: U2_P1_P0_1 NVMe 16-17 NVMe 22-23 Front HDD Board: Front HDD Board: Cable Cable...
  • Page 46 SLOT6 CPU0 CPU1 Motherboard: A1: U2_P0_P2_0 System Rear Side PCIe A2: U2_P0_P2_1 Cable A3: PCIE1_PWR1 (Power Cable/Reseved) Slot 6: -- System Hardware Installation - 46 -...
  • Page 47: Chapter 4 Motherboard Components

    Chapter 4 Motherboard Components Motherboard Components 32 31 CPU0 CPU1 Item Description 2 x 7 Pin ATX Backplane Power Connector 2 x 2 Pin P12V Backplane Power Connector 2 x 2 Pin P12V Backplane Power Connector 2 x 3 Pin Backplane Power Connector M.2 Slot (PCIe Gen3 x2, Supports NGFF-22110) M.2 Slot (PCIe Gen3 x4, Supports NGFF-22110) HDD Backplane Board Connector...
  • Page 48 Item Description TPM Module Connector (SPI Interface) IPMB Connector System Battery G-SC Module Connector OCP 3.0 Connector (PCIe Gen5 x16) Power Supply Connector#2 (Secondary) 2 x 4 Pin P12V GPU Power Connector 2 x 2 Pin Slot Power Connector 2 x 2 Pin Slot Power Connector 2 x 2 Pin Slot Power Connector MCIO Connector (U2_P1_P3_1) MCIO Connector (U2_P1_P2_0/U2_P1_P2_1)
  • Page 49: Jumper Settings

    Jumper Settings Clear CMOS CLR_CMOS Default Enable 1 2 3 BMC1 BMC2 BIOS2 BIOS1 NCSI Sw ch G-SC SW.1 NCSI_SW Onboard LAN CPU0 CPU1 Slot#1 OCP3.0 Slot#2 OCP3.0 HOST_SMBUS_SEL BIOS defined Reserved BIOS_PWD Clear supervisor password Normal [Default] BIOS_RCVR BIOS recovery mode Normal [Default] Motherboard Components - 49 -...
  • Page 50: G-Sc Module

    G-SC Module 4-3-1 CDCR114 BMC1 BMC2 BIOS2 BIOS1 Item Description 10/100/1000 Server Management LAN Port 1GbE LAN Port #2 1GbE LAN Port #1 USB 3.2 Gen1 Port x 2 Mini DP Port Motherboard Components - 50 -...
  • Page 51: Backplane Board Storage Connector

    Backplane Board Storage Connector 4-4-1 CBP20P0 10 12 Item Description Item Description HDD0 HDD14 HDD1 HDD15 HDD2 HDD16 HDD3 HDD17 HDD4 HDD18 HDD5 HDD19 HDD6 HDD20 HDD7 HDD21 HDD8 HDD22 HDD9 HDD23 HDD10 HDD24 HDD11 HDD25 HDD12 HDD26 HDD13 HDD27 Motherboard Components - 51 -...
  • Page 52: Cbp2025 (Rear System Storage Board)

    4-4-2 CBP2025 (Rear System Storage Board) Item Description MCIO 4i (SFF-TA1016/U_2_0) MCIO 4i (SFF-TA1016/U_2_1) SlimSAS 4i Connector (SFF-8654/SL_SAS0 Motherboard Components - 52 -...
  • Page 53: Chapter 5 Bios Setup

    Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters, loading the operating system etc. The BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
  • Page 54  Main This setup page includes all the items of the standard compatible BIOS.  Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
  • Page 55: The Main Menu

    The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
  • Page 56 Parameter Description BIOS Information Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information (Note1) BMC Firmware Version (Note1) Displays BMC firmware version information.
  • Page 57 Parameter Description Onboard LAN Information LAN1/LAN2 MAC Address (Note) Displays LAN MAC address information. System Date Sets the date following the weekday-month-day-year format. System Time Sets the system time following the hour-minute-second format. (Note) The number of LAN ports listed will depend on the motherboard / system model. BIOS Setup - 57 -...
  • Page 58: Advanced Menu

    Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components. Select a submenu item, then press <Enter> to access the related submenu screen. BIOS Setup - 58 -...
  • Page 59: Cpu Configuration

    5-2-1 CPU Configuration Description Parameter Enable/Disable the CPU Virtualization. SVM Mode Options available: Disabled, Enabled. Default setting is Enabled. Press [Enter] to view the memory information related to CPU 0/1. CPU 0/1 Information BIOS Setup - 59 -...
  • Page 60: Nvme Configuration

    5-2-2 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system. Enable/Disable NVMe LED Control. NVMe LED Control Options available: System Default, Disabled, Enabled. Default setting is System Default. BIOS Setup - 60 -...
  • Page 61: Sata Configuration

    5-2-3 SATA Configuration Parameter Description SATA Configuration No onboard SATA in this system. BIOS Setup - 61 -...
  • Page 62: Usb Configuration

    5-2-4 USB Configuration Parameter Description USB Configuration USB Module Version Displays the USB module version information. USB Controllers Displays the supported USB controllers. USB Devices: Displays the USB devices connected to the system. Enable/Disable the Legacy USB support function. AUTO option disables legacy support if no USB devices are connected.
  • Page 63 Parameter Description Selects the time-out value during a USB mass storage device reset. Device reset time-out Options available: 10 sec, 20 sec, 30 sec, 40 sec. Default setting is 20 sec. Maximum time the device will take before it properly reports itself to the Host Controller.
  • Page 64: Pci Subsystem Settings

    5-2-5 PCI Subsystem Settings BIOS Setup - 64 -...
  • Page 65 Description Parameter Displays the PCI Bus Driver version information. PCI Bus Driver Version U2_P0_P0/1/2, U2_P1_P0/2/3 Change PCIe lanes. OCP# Options available: Disabled, Auto, x8, x16, x4x4, x8x8, x8x4x4, x4x4x8, x4x4x4x4. Default setting is Auto. Lanes (Note1) When enabled, this setting will initialize the device expansion ROM U2_P0_P0/1/2, U2_P1_P0/2/3 for the related devices.
  • Page 66: Ast2600 Super Io Configuration

    5-2-6 AST2600 Super IO Configuration Description Parameter AST2600 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Press [Enter] for configuration of advanced items. Configuration BIOS Setup - 66 -...
  • Page 67: Serial Port 1 Configuration

    5-2-6-1 Serial Port 1 Configuration Description Parameter Serial Port 1 Configuration Enable/Disable the Serial Port (COM). When set to Enabled allows you to configure the Serial port 1 settings. When set to Disabled, displays no Serial Port (Note) configuration for the serial port. Options available: Disabled, Enabled.
  • Page 68: Serial Port Console Redirection

    5-2-7 Serial Port Console Redirection Parameter Description Select whether to enable console redirection for specified device. Console COM1/Serial Over LAN redirection enables the users to manage the system from a remote Console Redirection (Note) location. Options available: Enabled, Disabled. Default setting is Disabled. Press [Enter] to configure advanced items.
  • Page 69 Parameter Description Parity Š – A parity bit can be sent with the data bits to detect some transmission errors. – Even: parity bit is 0 if the num of 1's in the data bits is even. – Odd: parity bit is 0 if num of 1's in the data bits is odd. –...
  • Page 70 Parameter Description Legacy Console Redirection Press [Enter] to configure advanced items. Redirection COM Port Š – Selects a COM port for Legacy serial redirection. – Default setting is COM1/SOL. Resolution Š – Selects the number of rows and columns used in Console Redirection for legacy OS support.
  • Page 71 Parameter Description Flow Control Š – Flow control can prevent data loss from buffer overflow. When sending data, if the receiving buffers are full, a 'stop' signal can Serial Port for Out-of-Band be sent to stop the data flow. Once the buffers are empty, a 'start' EMS Console Redirection signal can be sent to re-start the flow.
  • Page 72: Network Stack Configuration

    5-2-8 Network Stack Configuration Parameter Description Enable/Disable the UEFI network stack. Network Stack Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 PXE feature. Ipv4 PXE Support (Note) Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 HTTP feature. Ipv4 HTTP Support (Note) Options available: Enabled, Disabled.
  • Page 73: Post Report Configuration

    5-2-9 Post Report Configuration Parameter Description Post Report Configuration Error Message Report Enable/Disable the POST Error Message support. Post Error Message Options available: Enabled, Disabled. Default setting is Enabled. Halt On Options available: No Error, All Error. Default setting is No Error. BIOS Setup - 73 -...
  • Page 74: Trusted Computing

    5-2-10 Trusted Computing Parameter Description Configuration Enable/Disable BIOS support for security device. OS will not show security device. TCG EFI protocol and INT1A interface will not be Security Device Support available. Options available: Disabled, Enabled. Default setting is Enabled. Select Enable to activate TPM support feature. SPI TPM Support Options available: Disabled, Enabled.
  • Page 75: Psp Firmware Versions

    5-2-11 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information. Items on this window are non-configurable. BIOS Setup - 75 -...
  • Page 76: S5 Rtc Wake Settings

    5-2-12 S5 RTC Wake Settings Parameter Description Enable/Disable system wake on alarm event. Options available: Disabled, Fixed Time, Dynamic Time. When Fixed Time Wake System from S5 is selected, system will wake on the hr::min::sec specified. Default setting is Disabled. BIOS Setup - 76 -...
  • Page 77: Graphic Output Configuration

    5-2-13 Graphic Output Configuration Parameter Description Selects output device type. Output Device Type Options available: First loaded Device, Onboard Device, External Device, Specific Device. Default setting is Onboard Device. BIOS Setup - 77 -...
  • Page 78: Amd Mem Configuration Status

    5-2-14 AMD Mem Configuration Status Description Parameter Press [Enter] to view the memory configuration status related to CPU 0/1. CPU 0/1 BIOS Setup - 78 -...
  • Page 79: Tls Auth Configuration

    5-2-15 Tls Auth Configuration Parameter Description Press [Enter] for configuration of advanced items. Enroll Cert Š – Press [Enter] to enroll a certificate • Enroll Cert Using File • Cert GUID Server CA Configuration Input digit character in 1111111-2222-3333-4444-1234567890ab format. –...
  • Page 80: Ram Disk Configuration

    5-2-16 RAM Disk Configuration Parameter Description Specifies the type of memory to use from available memory pool in system to create a disk. Disk Memory Type Options available: Boot Service Data, Reserved. Default setting is Boot Service Data. Creates a raw RAM disk. Size (Hex) Š...
  • Page 81: Iscsi Configuration

    5-2-17 iSCSI Configuration Parameter Description Press [Enter] and name iSCSI Initiator. Only IQN format is accepted. iSCSI Initiator Name Range: from 4 to 223 Add an Attempt Press [Enter] to configure advanced items. Delete Attempts Press [Enter] to configure advanced items. Change Attempt Order Press [Enter] to configure advanced items.
  • Page 82: Intel(R) I350 Gigabit Network Connection

    5-2-18 Intel(R) I350 Gigabit Network Connection BIOS Setup - 82 -...
  • Page 83 Description Parameter Press [Enter] to configure advanced items. Link Speed Š – Allows for automatic link speed adjustment. – Options available: Auto Negotiated, 10 Mbps Half, 10 Mbps Full, 100 Mbps Half, 100 Mbps Full. Default setting is Auto Negotiated. Wake On LAN NIC Configuration Š...
  • Page 84: Vlan Configuration

    5-2-19 VLAN Configuration Parameter Description Press [Enter] to configure advanced items. Create new VLAN Š VLAN ID Š – Sets VLAN ID for a new VLAN or an existing VLAN. – Press the <+> / <-> keys to increase or decrease the desired values. –...
  • Page 85: Mac Ipv4 Network Configuration

    5-2-20 MAC IPv4 Network Configuration Parameter Description Indicates whether network address is configured successfully or not. Configured Options available: Enabled, Disabled. Default setting is Disabled. Options available: Enabled, Disabled. Default setting is Disabled. Enable DHCP (Note) Local IP Address Press [Enter] to configure local IP address. (Note) Press [Enter] to configure local NetMask.
  • Page 86: Mac Ipv6 Network Configuration

    5-2-21 MAC IPv6 Network Configuration Parameter Description Press [Enter] to configure advanced items. Displays the MAC Address information. Š Interface ID Š – The 64 bit alternative interface ID for the device. The string is colon separated. e.g. ff:dd:88:66:cc:1:2:3. DAD Transmit Count Š...
  • Page 87: Amd Cbs Menu

    AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU-related information that the BIOS automatically sets. Select a submenu item, then press [Enter] to access the related submenu screen. BIOS Setup - 87 -...
  • Page 88 5-3-1 CPU Common Options BIOS Setup - 88 -...
  • Page 89: Cpu Common Options

    Parameter Description CPU Common Options Performance Press [Enter] for configuration of advanced items. Allow REP-MOV/STOS to use non-caching streaming stores for large sizes. REP-MOV/STOS Streaming Options available: Disabled, Enabled. Default setting is Enabled. Prefetcher settings Press [Enter] for configuration of advanced items. Core Watchdog Press [Enter] for configuration of advanced items.
  • Page 90 Parameter Description Enhanced REP MOVSB/ Options available: Disabled, Enabled, Auto. Default setting is Auto. STOSB (ERSM) Enable/Disable the log Transparent errors function. Log Transparent Errors Options available: Auto, Disabled, Enabled. Default setting is Auto. Enable/Disable AVX512. AVX512 Options available: Disabled, Enabled, Auto. Default setting is Auto. Options available: Disabled, Enabled, Auto.
  • Page 91 5-3-1-1 Performance Parameter Description Performance Options available: Normal Operation, Customized. Default setting is Normal OC Mode (Note) Operation. Allows you to accept or decline enabling Custom Core Pstates. When Custom Core Pstates accepted, you can disable or customize core pstates. Allows you to accept or decline enabling CCDs, processor cores and threads.
  • Page 92 5-3-1-2 Prefetcher Settings Parameter Description Prefetcher settings Enable/Disable L1 Stream HW Prefetcher. L1 Stream HW Prefetcher Options available: Disable, Enable, Auto. Default setting is Auto. Use memory access history of individual instructions to fetch additional lines when each access is a constant distance from the previous. L1 Stride Prefetcher Enable/Disable L1 Stride Prefetcher.
  • Page 93 5-3-1-3 Core Watchdog Parameter Description Core Watchdog Enable/Disable CPU Watchdog Timer. Core Watchdog Timer Enable (Note) Options available: Disabled, Enabled, Auto. Default setting is Auto. Select the CPU Watchdog Timer interval. Options available: 2.681s, 1.340s, 669.41ms, 334.05ms, 166.37ms, Core Watchdog Timer Interval 82.53ms, 40.61ms, 20.970ms, 10.484ms,5.241ms, 2.620ms, 1.309ms, 654.08us, 326.4us, 162.56us, 80.64us, 39.68us, Auto.
  • Page 94: Df Common Options

    5-3-2 DF Common Options Parameter Description DF Common Options Memory Addressing Press [Enter] for configuration of advanced items. ACPI Press [Enter] for configuration of advanced items. Link Press [Enter] for configuration of advanced items. SDCI Press [Enter] for configuration of advanced items. Probe Filter Press [Enter] for configuration of advanced items.
  • Page 95 Parameter Description Options available: Auto, 1 Segment, 2 Segments, 4 Segment. Number of PCI Segments Default setting is Auto. Options available: Disabled, Enabled, Auto. Default setting is Auto. CCM Throttler Clean Victim FTI Cmd Options available: Disabled, Enabled, Auto. Default setting is Auto. Balancing Options available: Disabled, Enabled, Auto.
  • Page 96: Memory Addressing

    5-3-2-1 Memory Addressing Parameter Description Memory Addressing Specifies the number of desired NUMA nodes per socket. Options available: NPS0, NPS1, NPS2, NPS4, Auto. Default setting is Auto. NUMA nodes per socket NOTE! • Available options may vary by system configuration. •...
  • Page 97 5-3-2-2 ACPI Parameter Description ACPI ACPI SRAT L3 Cache As Enable/Disable report each L3 cache as a NUMA Domain to the OS. Options available: Disabled, Enabled, Auto. Default setting is Auto. NUMA Domain Determines how the SLIT distances are declared. ACPI SLIT Distance Control Options available: Manual, Auto.
  • Page 98 5-3-2-3 Link Parameter Description Enable/Disable GMI link encryption. GMI encryption control Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable/Disable xGMI link encryption. xGMI encryption control Options available: Disabled, Enabled, Auto. Default setting is Auto. Configures the number of xGMI2 links used on a multi-socket system. xGMI Link Configuration Options available: Auto, 3 xGMI Links, 4 xGMI Links, 2 xGMI Links + 2 PCI Links.
  • Page 99 Parameter Description Press [Enter] to configure the xGMI AC/DC Coupled link. xGMI AC/DC Coupled Link xGMI AC/DC Coupled Link Control (Note) Š – Options available: Manual, Auto. Default setting is Auto. Press [Enter] to configure the xGMI Channel Type. xGMI Channel Type xGMI Channel Type Control (Note) Š...
  • Page 100 5-3-2-4 SDCI Parameter Description SDCI Options available: Disabled, Enabled, Auto. Default setting is Auto. (Note) DisRmSteer Options available: Disabled, Enabled, Auto. Default setting is Auto. (Note) Advanced items prompt when this item is defined. BIOS Setup - 100 -...
  • Page 101: Probe Filter

    5-3-2-5 Probe Filter Parameter Description Specifies whether multiple memory/CXL channels will share probe filter Organization storage. Options available: Auto, Dedicated, Shared. Default setting is Dedicated. Controls PDR settings that may impact performance by workload and/or Periodic Directory Rinse (PDR) processor. Tuning Options available: Memory-Sensitive, Cache-Bound, Neutral, Adaptive, Auto.
  • Page 102: Umc Common Options

    5-3-3 UMC Common Options Parameter Description UMC Common Options DDR Addressing Options Press [Enter] for configuration of advanced items. DDR Controller Configuration Press [Enter] for configuration of advanced items. DDR MBIST Options Press [Enter] for configuration of advanced items. DDR RAS Press [Enter] for configuration of advanced items.
  • Page 103 5-3-3-1 DDR Addressing Options Parameter Description DDR Addressing Options Interleaves memory blocks across the DRAM chip selects for node 0. Chipselect Interleaving Options available: Disabled, Auto. Default setting is Auto. Enable or disable bank addressing hashing. Address Hash Bank Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable or disable CS addressing hashing.
  • Page 104 5-3-3-2 DDR Controller Configuration Parameter Description DDR Controller Configuration DDR Power Options Press [Enter] for configuration of advanced items. Memory Channel Disable Press [Enter] for configuration of advanced items. Refresh Management (RFM) Press [Enter] for configuration of advanced items. Memory Context Restore Options available: Disabled, Enabled, Auto.
  • Page 105 5-3-3-2-1 DDR Power Options Parameter Description DDR Power Options Enable or disable DDR power down mode. Power Down Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. Sub Urgent Refresh Lower Specifies the stored refresh limit required to enter sub-urgent refresh mode. Bound Urgent Refresh Limit Specifies the stored refresh limit required to enter urgent refresh mode.
  • Page 106 5-3-3-2-2 Memory Channel Disable Parameter Description Memory Channel Disable Memory Channel Disable Float Options available: Disabled, Enabled. Default setting is Disabled. Power Good Memory Channel Disable Bitmask CPU0/1 Channel_# Press [Enter] to enable/disable specific memory channel. BIOS Setup - 106 -...
  • Page 107 5-3-3-2-3 Refresh Management (RFM) Parameter Description Refresh Management (RFM) Configure Refresh Management. Refresh Management Options available: Enable, Disable, Auto, Force Enable. Default setting is Auto. Options available: Auto, Disable, ARFM Level A, ARFM Level B, ARFM Adaptive Refresh Management Level C. Default setting is Auto. RAA Initial Management Override Rolling Accumulated ACT Initial Management Threshold.
  • Page 108 5-3-3-3 DDR MBIST Options Parameter Description DDR MBIST Options Enable/Disable the Memory MBIST function. MBIST Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. Selects MBIST Test Mode. Interface Mode: Tests Single and Multiple CS transactions and Basic Connectivity. MBIST Test Mode (Note1) Data Eye Mode: Measures Voltage vs.
  • Page 109 Parameter Description Data Eye Press [Enter] to configure advanced items. (Note2) This item appears when DDR Healing BIST is defined. BIOS Setup - 109 -...
  • Page 110 5-3-3-3-1 Data Eye Parameter Description Data Eye Pattern Select Options available: PRBS, SSO, Both. Default setting is PRBS. Pattern Length Determines the pattern length. The possible options are N=3..12. This item helps read the aggressors channels. Aggressor Channel Options available: One Sub-Channel, Half Channels, All Channels. Default setting is All Channels.
  • Page 111 Parameter Description Target Static Lane Select This item is configurable when Target Static Lane Control is set to Upper 32 bits Enabled. Target Static Lane Select This item is configurable when Target Static Lane Control is set to Lower 32 bits Enabled.
  • Page 112 5-3-3-4 DDR RAS Parameter Description DDR RAS Enable/Disable the Data Poisoning function. Data Poisoning Options available: Auto, Enabled, Disabled. Default setting is Auto. DRAM Boot Time Post Package Enable/Disable the DRAM Boot Time Post Package Repair function. Options available: Enable, Disable. Default setting is Disable. Repair DRAM Runtime Post Package Enable/Disable the DRAM Runtime Post Package Repair function.
  • Page 113 Parameter Description DRAM ECC Enable Š – Enable/Disable DRAM ECC. When set to Auto, it will set ECC to enable. – Options available: Auto, Enabled, Disabled. Default setting is Auto. DRAM UECC Retry Š – Enable/Disable DRAM UECC Retry. – Options available: Auto, Enabled, Disabled. Default setting is Disabled.
  • Page 114 Parameter Description – DRAM ECS WriteBack Suppression » Options available: Auto, Enable, Disable. Default setting is Auto. DRAM Scrubbers (continued) – DRAM X4 WriteBack Suppression » Options available: Auto, Enable, Disable. Default setting is Auto. Configure DRAM Corrected Error Counter function. DRAM Corrected Error Counter Options available: Disable, NoLeakMode, LeakMode.
  • Page 115 5-3-3-5 DDR Bus Configuration Parameter Description DDR Bus Configuration Press [Enter] to configure advanced items. RTT_NOM_WR P-State 0 Š – Default setting is Auto. RTT_NOM_RD P-State 0 Š – Default setting is Auto. P-State 0 Dram ODT RTT_WR P-State 0 Š...
  • Page 116 Parameter Description Select the ODT impedance for all DBYTE IOs. Options available: Auto, High Impedance, 480 ohm, 240 ohm, 160 ohm, Processor ODT Pull Up 120 ohm, 96 ohm, 80 ohm, 68.6 ohm, 60 ohm, 53.3 ohm,48 ohm, 43.6 ohm, impedance 40 ohm, 36.9 ohm, 34.3 ohm, 32 ohm, 30 ohm, 28.2 ohm, 26.7 ohm, 25.3 ohm.
  • Page 117 5-3-3-6 Enforce POR Parameter Description Enforce POR Decline/Accept to configure the advanced items. Accept Active Memory Timing Active memory Timing Settings. Options available: Auto, Enabled. Default setting is Auto. Settings (Note) Specifies the memory target speed in MT/s. Memory Target Speed Options available: Auto, DDR3600, DDR4000, DDR4400, DDR4800, DDR5200, DDR5600, DDR6000, DDR6400.
  • Page 118 5-3-3-7 DDR Training Options Parameter Description DDR Training Options Specify PDA enumeration mode. DRAM PDA Enumerate ID Options available: Auto, Toggling PDA enumeration mode, Legacy PDA Programming Mode enumeration mode. Default setting is Auto. Press [Enter] to configure advanced items. Periodic Training Mode Š...
  • Page 119 5-3-3-8 DDR Security Parameter Description Security Enable/Disable Transparent SME. TSME Options available: Auto, Enabled, Disabled. Default setting is Auto. Options available: AES-128, AES-256. Default setting is AES-256. Enable/Disable Data Scrambling. Data Scramble Options available: Enabled, Disabled. Default setting is Enabled. SME-MK Options available: Enabled, Disabled.
  • Page 120 5-3-3-9 DDR PMIC Configuration Parameter Description DDR PMIC Configuration Enables support for PMIC Error Reporting. PMIC Error Reporting Options available: Auto, False, True. Default setting is Auto. Options available: Secure Mode, Programmable Mode. PMIC Operation Mode Default setting is Programmable Mode. Options available: Always, Never, Once.
  • Page 121 5-3-3-10 DDR Miscellaneous Parameter Description DDR Miscellaneous ODTS CMD Throttle Threshold Options available: Auto, > 85'C, > 90'C, > 95'C. Default setting is Auto. BIOS Setup - 121 -...
  • Page 122: Nbio Common Options

    5-3-4 NBIO Common Options Parameter Description NBIO Common Options SMU Common Options Press [Enter] for configuration of advanced items. NBIO RAS Common Press [Enter] for configuration of advanced items. Options PCIE Press [Enter] for configuration of advanced items. nBif Common Options Press [Enter] for configuration of advanced items.
  • Page 123 5-3-4-1 SMU Common Options Parameter Description SMU Common Options Power Policy Quick Options available: Standard, Best Performance, Energy Efficient. Setting Default setting is Standard. TDP Control Options available: Manual, Auto. Default setting is Auto. PPT Control Options available: Manual, Auto. Default setting is Auto. Selects use the fused Determinism or set customized Determinism.
  • Page 124 Parameter Description Enable/Disable the CPPC feature. CPPC Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable/Disable the HSMP support. HSMP Support Options available: Disabled, Enabled, Auto. Default setting is Auto. SVI3 SVC Speed Control Options available: Auto, Manual. Default setting is Auto. Options available: Auto, Disable, 1 stack, 2 stack, 4 stack.
  • Page 125 5-3-4-2 NBIO RAS Common Options Parameter Description NBIO RAS Common Options NBIO RAS Control Options available: Disabled, MCA, Auto. Default setting is Auto. The value may be used to mask SyncFlood caused by NBIO RAS options. NBIO SyncFlood Generation Options available: Enabled, Disabled, Auto. Default setting is Auto. The value may be used to enable SyncFlood reporting to APML.
  • Page 126 5-3-4-3 PCIE BIOS Setup - 126 -...
  • Page 127 Parameter Description PCIE Options available: Auto, Disabled, Enabled. Default setting is Auto. Data Object Exchange RTM Margining Support Options available: Auto, Disable, Enable. Default setting is Auto. Multi Auto Speed Change On Options available: Auto, Disable, Enable. Default setting is Auto. Last Rate Multi Upstram Auto Speed Options available: Auto, Disabled, Enabled.
  • Page 128 Parameter Description Options available: Maximum speed, Gen1, Gen2, Gen3, Gen4, Gen5, PCIE Link Speed Capability Auto. Default setting is Auto. Options available: Maximum Speed, GEN1, GEN2, GEN3, GEN4, GEN5, PCIE Target Link Speed Auto. Default setting is Auto. ASPM Control Options available: Disable, L0s, L1, Auto.
  • Page 129 5-3-4-4 nBif Common Options Parameter Description RCC_DEV0 ACS Rcc_Dev0 Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. AER Rcc_Dev0 Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. DlfEnableStrap1 Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. Phy16GTStrap1 Š...
  • Page 130 Parameter Description P2PEgressStrap5 Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. DirectTranslatedStrap5 Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. SsidEnStrap5 Š – Options available: Auto, Disabled, Enabled. Default setting is Auto. PriEnPageReq Š –...
  • Page 131 5-3-4-5 IOMMU/Security Parameter Description Enable/Disable the SEV-SNP support. SEV-SNP Support Options available: Disable, Enable. Default setting is Disable. Enable/Disable DRTM Memory reservation. DRTM Memory Reservation Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable/Disable DRTM ACPI virtual device. DRTM Virtual Device Support Options available: Disabled, Enabled, Auto.
  • Page 132 5-3-4-6 Enable Port Bifurcation Parameter Description Options available: Disable, Enable, Auto. Default setting is Auto. Enable Bifurcation (Note) Socket0 Slot Info Override Socket1 Slot Info Override (Note) Advanced items prompt when this item is defined. BIOS Setup - 132 -...
  • Page 133 5-3-4-7 Link EQ Preset Options Parameter Description Press [Enter] to configure advanced items. GEN3/4/5 Preset Search Mask Configuration Š – Options available: Custom, Auto. Default setting is Auto. BIOS Setup - 133 -...
  • Page 134: Fch Common Options

    5-3-5 FCH Common Options Parameter Description FCH Common Options I3C/I2C Configuration Options Press [Enter] for configuration of advanced items. SATA Configuration Options Press [Enter] for configuration of advanced items. USB Configuration Options Press [Enter] for configuration of advanced items. AC Power Loss Options Press [Enter] for configuration of advanced items.
  • Page 135 5-3-5-1 I3C/I2C Configuration Options Parameter Description I3C/I2C Configuration Options Options available: Both Disabled, I3C Enabled, I2C Enabled, Auto. I3C/I2C 0/1/2/3 Enable Default setting is Auto. I2C 4/5 Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. Release SPD Host Control Options available: Disabled, Enabled.
  • Page 136 5-3-5-2 SATA Configuration Options Parameter Description SATA Configuration Options Enable/Disable OnChip SATA controller. SATA Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. SATA RAS Support Options available: Disabled, Enabled, Auto. Default setting is Auto. SATA Staggered Spin-up Options available: Disabled, Enabled, Auto. Default setting is Auto. SATA Disabled AHCI Prefetch Options available: Disabled, Enabled, Auto.
  • Page 137 5-3-5-3 USB Configuration Options Parameter Description USB Configuration Options Enable/Disable USB controller. XHCI Controller0/1 enable Options available: Enabled, Disabled, Auto. Default setting is Auto. Press [Enter] for configuration of advanced items. MCM USB enable XHCI2/ XHCI3 enable (Socket1) Š – Options available: Enabled, Disabled, Auto. Default setting is Auto. BIOS Setup - 137 -...
  • Page 138 5-3-5-4 AC Power Loss Options Parameter Description AC Power Loss Options Selects the AC Loss Control Method. AC Loss Control Options available: Power Off, Power On, Last State. Default setting is Last State. Enable/Disable set FCH power failed shadow by AC Loss control policy in Set FCH Power failed ABL.
  • Page 139 5-3-5-5 Uart Configuration Options Parameter Description Uart Configuration Options Uart 0/1/2/3 Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 139 -...
  • Page 140 5-3-5-6 FCH RAS Options Parameter Description FCH RAS Options Enable/Disable the ALink RAS Support. ALink RAS Support Options available: Disabled, Enabled, Auto. Default setting is Auto. Enables AB to forward downstream sync-flood message to system Reset After Sync-Flood controller. Options available: Enable, Disable, Auto. Default setting is Auto. BIOS Setup - 140 -...
  • Page 141: Miscellaneous Options

    5-3-5-7 Miscellaneous Options Parameter Description Miscellaneous Options Select whether or not Enable the Spread Spectrum Feature. FCH Spread Spectrum Options available: Disabled, Enabled, Auto. Default setting is Disabled. Enable/Disable Boot Timer. Boot Timer Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 141 -...
  • Page 142: Soc Miscellaneous Control

    5-3-6 SOC Miscellaneous Control Parameter Description SOC Miscellaneous Control Enable/Disable the ConsoleOut function for ABL. ABL Console Out Control (Note) Options available: Disable, Enable, Auto. Default setting is Auto. ABL Console Out Serial Options available: eSPI, SOC UART0, SOC UART1, Auto. Default setting is Auto.
  • Page 143 Parameter Description Options available: False, True. Default setting is False. PSP error injection support Press [Enter] for configuration of advanced items. FAR enforcement state Š – Default setting is Enabled. Firmware Anti-rollback (FAR) SPL value in the CPU Fuse Š SPL value in the SPL table Š...
  • Page 144: Cxl Common Options

    5-3-7 CXL Common Options Parameter Description CXL Common Options CXL Control Options available: Auto, Enabled, Disabled. Default setting is Auto. Options available: Normalized address, System address, Auto. CXL Physical Addressing Default setting is Auto. CXL Memory Attribute Options available: Auto, Enabled, Disabled. Default setting is Auto. Options available: Enabled, Disabled.
  • Page 145 Parameter Description Press [Enter] for configuration of advanced items. CXL Protocol Error Reporting Š – Options available: Disabled, SameAsPcieAer, ForceAerFwFirstIfCxlPresent. Default setting is SameAsPcieAer. CXL Component Error Reporting Š – Options available: Allow OS First, Force FW-First, CXL RAS Debug FW-First. Default setting is Debug FW-First. CXL Root Port Isolation Š...
  • Page 146: Amd Pbs Menu

    AMD PBS Menu AMD PBS Option menu displays submenu options for configuring the function of AMD PBS. Select a submenu item, then press [Enter] to access the related submenu screen. Parameter Description Protect some AMD specific variables for CBS, PBS and AOD. If locked, some AMD Variable Protection utilities like RU that modify variable at runtime do not work.
  • Page 147: Ras

    5-4-1 RAS Parameter Description Enable/Disable the Periodic SMI for polling [MCA Threshold] error. RAS Periodic SMI Control Options available: Disabled, Enabled. Default setting is Enabled. SMI Threshold Configures the SMI Threshold value. SMI Scale Configures the SMI Scale value. Defines the unit of time scale. SMI Scale Unit Options available: millisecond, second, minute.
  • Page 148 Parameter Description PCIe Root Port UnCorr Err Initialize the PCIe AER Uncorrected Error Mask register of Root Port. Mask Reg PCIe Root Port UnCorr Err Initialize the PCIe AER Uncorrected Error Severity register of Root Port. Sev Reg PCIe Device Corr Err Mask Initialize the PCIe AER Corrected Error Mask register of PCIe device.
  • Page 149: Chipset Setup Menu

    Chipset Setup Menu Chipset Setup menu displays submenu options for configuring the function of the North Bridge. Select a submenu item, then press <Enter> to access the related submenu screen. Parameter Description PCIe Compliance Mode Options available: Off, On. Default setting is Off. Enable/Disable program all VR on MB.
  • Page 150: North Bridge

    5-5-1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information. CPU 0/1 Information Press [Enter] to view information related to CPU 0/1. BIOS Setup - 150 -...
  • Page 151: Server Management Menu

    Server Management Menu Parameter Description Enable/Disable FRB-2 timer (POST timer). FRB-2 Timer Default setting is Enabled. FRB-2 Timer Configures the FRB-2 Timer timeout. timeout Default setting is 20 minutes. Configures the FRB-2 Timer policy. FRB-2 Timer Policy Options available: Do Nothing, Reset, Power Down, Power Cycle. Default setting is Do Nothing.
  • Page 152 Parameter Description System Event Log Press [Enter] to configure advanced items. View FRU Press [Enter] to view the FRU information. Information BMC VLAN Press [Enter] to configure advanced items. configuration BMC network Press [Enter] to configure advanced items. configuration IPv6 BMC Network Press [Enter] to configure advanced items.
  • Page 153: System Event Log

    5-6-1 System Event Log Parameter Description Enabling / Disabling Options Change this item to enable or disable all features of System Event SEL Components Logging during boot. Options available: Disabled, Enabled. Default setting is Enabled. Erasing Settings Choose options for erasing SEL. Erase SEL Options available: No/Yes, On next reset/Yes, On every reset.
  • Page 154: View Fru Information

    5-6-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased BIOS Setup - 154 -...
  • Page 155: Bmc Vlan Configuration

    5-6-3 BMC VLAN Configuration Description Parameter BMC VLAN Configuration Select to configure BMC VLAN ID. The valid range is from 0 to 4094. When BMC VLAN ID set to 0, BMC VLAN ID will be disabled. Select to configure BMC VLAN Priority. The valid range is from 0 to 7. BMC VLAN Priority When BMC VLAN ID is set to 0, BMC VLAN Priority will not be selected.
  • Page 156: Bmc Network Configuration

    5-6-4 BMC Network Configuration Parameter Description Select NCSI and Dedicated Options available: Do Nothing, Mode1 (Dedicated), Mode2 (NCSI), Mode3 (Failover). Default setting is Do Nothing. Lan Channel 1 Selects to configure LAN channel parameters statically or dynamically (DHCP). Do nothing option will not modify any BMC network parameters Configuration Address source during BIOS phase.
  • Page 157: Ipv6 Bmc Network Configuration

    5-6-5 IPv6 BMC Network Configuration Parameter Description IPv6 BMC network configuration IPv6 BMC Lan Channel 1 Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS IPv6 BMC Lan Option phase.
  • Page 158: Security Menu

    Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
  • Page 159: Secure Boot

    5-7-1 Secure Boot The Secure Boot feature is applicable if supported by your Operating System. If your Operating System is not supporting Secure Boot, the system will hang when starting the Operating System. Parameter Description System Mode Displays if the system is in User mode or Setup mode. Enable/ Disable the Secure Boot function.
  • Page 160 Parameter Description Press [Enter] to configure advanced items. Please note that this item is configurable when Secure Boot Mode is set to Custom. Factory Key Provision Š – Allows to provision factory default Secure Boot keys when system is in Setup Mode.
  • Page 161: Boot Menu

    Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Parameter Description Boot Configuration Number of seconds to wait for setup activation key. 65535 (0xFFFF) Setup Prompt Timeout means indefinite waiting.
  • Page 162 Parameter Description FIXED BOOT ORDER Priorities Press [Enter] to configure the boot priority. By default, the server searches for boot devices in the following sequence: Hard drive. Boot Option #1 / #2 / #3 / #4 / #5 CD-COM/DVD drive. USB device.
  • Page 163: Save & Exit Menu

    Save & Exit Menu The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press <Enter>. Parameter Description Save Options Saves changes made and closes the BIOS setup. Save Changes and Exit Options available: Yes, No.
  • Page 164: Bios Recovery

    5-10 BIOS Recovery The system has an embedded recovery technique. In the event that the BIOS becomes corrupt the boot block can be used to restore the BIOS to a working state. To restore your BIOS, please follow the instructions listed below: Recovery Instruction: 1.

Table of Contents