Disclaimer of Liability The information contained in this document is subject to change without notice. EtherWAN is not liable for any errors or omissions contained herein or for resulting damage in connection with the information provided in this manual.
▪▪ A flat-tipped screwdriver ▪▪ A grounding straps ▪▪ An anti-static pad Note: EW50-V series IoT gateway should be powered directly from a dedicated External AC/DC power supply and the DC power cable length should be less than 3 m.
Page 5
EW50-V Industrial LTE Cellular Gateway General Status .......................... 40 Cellular WAN ..........................41 Port Switch ..........................53 Ethernet WAN........................... 54 WAN Redundancy Policy ......................58 LAN ................................61 Port Forwarding............................63 Port Forwarding ........................64 DMZ ............................67 Firewall ..............................68 General .............................
Page 6
EW50-V Industrial LTE Cellular Gateway Port Connection ............................ 122 LAN ............................122 COM ............................122 TCP Transparent ........................124 Simulator ..........................126 Modbus ..............................127 RTU............................128 TCP ............................132 Tag ............................137 Tips for Tag Naming Rule ......................137 Gateway ..........................
Page 7
EW50-V Industrial LTE Cellular Gateway Log Viewer ..........................229 Chapter 4 Application Scenarios ........................230 4.1 New Firmware Notify via SMS and reply OTP code to Go ............230 Appendix .................................. 231 Specifications ..............................231 Contact Information .............................. 233...
Page 9
EW50-V Industrial LTE Cellular Gateway For NBTC Thailand...
Page 10
EW50-V Industrial LTE Cellular Gateway EMC (KN 32/35) Class A device only 사 용 자 안 내 문 이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기기로서가정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니다 ※ 사용자 안내문은 업무용 방송통신기자재 에만 적용한다 “...
Page 11
EW50-V Industrial LTE Cellular Gateway EU Declaration of Conformity Hereby, EtherWAN System, Inc. declares that the radio equipment type 4G Cellular Device is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.etherwan.com...
Page 12
EW50-V Industrial LTE Cellular Gateway FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
EW50-V Industrial LTE Cellular Gateway Chapter 1 Introduction 1.1 Introduction The EW50-V is the latest addition to the popular EW50 series. It provides reliable and secure connectivity designed for harsh environments, giving operations and IT read-time awareness with remote monitoring. Moreover, the EW50-V is a versatile 4G LTE smart gateway with Ethernet, serial, and digital I/O to satisfy most applications.
EW50-V Industrial LTE Cellular Gateway Chapter 2 Hardware Guide 2.1 Product Overview Front View LED present LTE/System/Status Serial 1/Serial 2/Power Reset hole RJ-45 10/100/1000 BASE-TX LAN 2 and LAN 1 / WAN port 6 pin Terminal Block for 2 X Serial, RS-485 RESET Hole 2 PIN Power Terminal Block...
Page 16
EW50-V Industrial LTE Cellular Gateway Top View LTE Antenna: ANT-A, ANT-B GPS Antenna (By Model) WAN port Micro SD card: SIM-A / SIM-B in plastic nano SIM Bottom View 4 pin Terminal Block for 1 x DI and 1 x DO Back View DIN Rail mount Side View...
Page 17
EW50-V Industrial LTE Cellular Gateway QR code and passowrd information:...
EW50-V Industrial LTE Cellular Gateway 2.2 DC Power EW50-V can be powered by connecting a DC power source to the terminal block. It supports 12 to 24VDC power input. “ ” connects to DC 12V to 24V and ” “ connects to DC 0V from your Power Supply. The following chart indicates the power terminal block pin assignments.
EW50-V Industrial LTE Cellular Gateway 2.3 LEDs Position Position Position Cellular Link Status: System Situation: Status Red Blinking – SIM is not ready. – Initial / all Network Orange – Power on (500ms on / 500ms off) disconnected. under initialization Red Steady –...
EW50-V Industrial LTE Cellular Gateway 2.4 RESET key You can reboot device via a pin to RESET hole for 1 second, For System Factory Default, you can long press RESET hole by a pin over 5 seconds for Reset to Factory Default, you also can press until LEDs, LTE + SYS + STS + Power, change to orange color, it means system received and acknowledge user, it’s going to factory default after you release RESET key.
EW50-V Industrial LTE Cellular Gateway 2.5 Hardware Installation This chapter describes how to install and configure the hardware. Mount the Unit The EW50-V can be mounted on DIN Rail in a cabinet with the mounting accessories. The mounting accessories are not screwed on the product when shipped from factory. Screw the DIN-rail bracket on the product first.
EW50-V Industrial LTE Cellular Gateway Insert the Nano SIM Card to SIM slot Remove the cover T8 screw on Micro SD / SIM card side of Top View. The dual SIM slot for SIM-A and SIM-B are plastic nano SIM. In this session, guide to install SIM-A. The sim slot is double side in drawer style and push-push to install-uninstall SIM card.
Page 23
EW50-V Industrial LTE Cellular Gateway 3. Align the sim card shape and place it. SIM-A 4. Reverse the draw side for SIM-B installed. SIM-B 5. Reverse the drawer side to keep SIM-A is up. 6. Push to install double side drawer and heard a kick tone to complete.
EW50-V Industrial LTE Cellular Gateway Insert the SD card Remove the cover T8 screw on Micro SD / SIM card side of Top View. By followed sequence to insert SD card and heard a kick sound, push to kick. ➔ ➔...
EW50-V Industrial LTE Cellular Gateway Install Cellular Antenna Followed the position ANT-A and ANT-B to install LTE antenna to get better antenna performance. Main Antenna is ANT-A.
EW50-V Industrial LTE Cellular Gateway Install GPS Antenna For specified Model (EW50-VUS and EW50-VP) which support GPS Only. Followed the position for GPS antenna installed.
EW50-V Industrial LTE Cellular Gateway Connecting DI and DO The EW50-V has a 4 pin Terminal Block for connecting DI / DO outlet. Pins assignment of connector is as below: DO - DO + DI - DI + Description Digital Digital Digital Digital...
EW50-V Industrial LTE Cellular Gateway Connecting to the Network Host LAN1 / WAN, LAN 2 port to connect 10/100/1000Mbps Ethernet. It can auto detect the transmission speed on the network and configure itself automatically. Connect one Ethernet cable to the RJ-45 port (LAN) of the device and plug another end of the Ethernet cable into your computer’s network ethernet port.
EW50-V Industrial LTE Cellular Gateway Chapter 3 Web Console Configuration In the following chapters, you will see these icon blocks. Modify set the filed just fill and waiting for Save to take effect. SAVE is just to save into configuration, but not take effect in system. Some icons you will meet: icon is for Save and Apply to take effect in system, and it shows what configuration are changed.
Page 31
EW50-V Industrial LTE Cellular Gateway Once Save and Apply, it shows.
EW50-V Industrial LTE Cellular Gateway Introduction To configure EW50-V for the first time, use an Ethernet cable to connect to the port. To connect to the EW50-V web console, open a web browser and enter the EW50-V IP address. The default IP address is 192.168.123.254. Default Administration username is “admin” and default guest product label account name are “guest”.
Page 33
EW50-V Industrial LTE Cellular Gateway Password Fail to lock: If user input incorrect password for 4 times, system will lock this account for 30 minutes. Password Expired: The password expired duration is 6 months, once expired, it shows below to prompt. User can select Remain to keep original password or Change a new password.
Page 34
EW50-V Industrial LTE Cellular Gateway Once click Change, or At the first-time login, the system will request a renew password page to change password. Password format rule must contain at least: (1) one lowercase letter, (2) one uppercase letter, (3) one number, (4) one special character, (5) minimum length of 16 characters.
EW50-V Industrial LTE Cellular Gateway 3.1 Dashboard This shows quick system information - Dashboard. Once click the hamberger “ ” ( left up corner), it will pop up Main Menu items. Here is Menu selection:...
Page 36
EW50-V Industrial LTE Cellular Gateway Dashboard content: System Uptime: Shows the System Up Time duration. Internet Uptime: Shows up time after Internet connected. Pave2Edge: status of connect to Pave2Edge, there are “Connected”, “Disconnect” GPS (option): Shows Latitude, Longitude and Altitude (meters) User Can copy Latitude and Longitude to Google map, then, get the location in map.
Page 37
EW50-V Industrial LTE Cellular Gateway Cellular Information: Shows Cellular Module SIM card status, RSSI and cellular information which is network type, Band and Operator Information. Ethernet: Shows LAN 1/WAN, LAN2 link status with different color; gray color means Link Down, blue color means Link Up.
EW50-V Industrial LTE Cellular Gateway General Status It shows gained IP address, gateway, IP address of DNS server, sim status, role of WAN and error reason once failed. Cellular Status It shows more detailed cellular information with mobile networking.
EW50-V Industrial LTE Cellular Gateway Cellular WAN There are several settings.
Page 42
EW50-V Industrial LTE Cellular Gateway General Status It shows simple cellular modem information as followed figure.
Page 43
EW50-V Industrial LTE Cellular Gateway Basic Settings It sets for basic information from SIM card PIN : This setting can set PIN code of the SIM card user inserted Web Access : This filed is for security reason, by default , can not access system from Cellular WAN. By default , it’s Reject.
Page 44
EW50-V Industrial LTE Cellular Gateway Advanced Settings Mode: setting for linking cellular mode is auto selection or designed cellular mode. Extra AT command: By default, keep it blank. In some case, special user needs to set AT command to cellular module. Band Lock: In some special application, special user can designate frequency band of cellular network.
Page 45
EW50-V Industrial LTE Cellular Gateway SIM policy EW50-V series support one cellular module with Dual SIM Single Standby (DSSS), User can insert 2 SIM card from different operator, System will base on followed mode to connecting in one SIM card.
Page 46
EW50-V Industrial LTE Cellular Gateway Cellular Guarantie Link The wording Guarantie is from, not typo. Keep network always on, the feature is Keep Always-On Connection None Cellular Fare Rate Detection Link Monitoring Take Action on Recovery There are many backgrounds mechanism to keep it always on, for this setting on web console, is for some setting need user to identify.
Page 47
EW50-V Industrial LTE Cellular Gateway Once enable Guarantie Link, you can select Checking Parameter to enable. Cellular Level Checking – Parameter to link checking is based on cellular networking Signaling, no payload from user traffic. Packet Level Checking – Parameter to link checking is based on user packets data, which consume a little user traffic.
Page 48
EW50-V Industrial LTE Cellular Gateway Cellular Level Checking: system will detect cellular link status by no payload traffic. Fail Connections: Number of cellular network connection fail, to judge it fails. Default is 1 RSSI Monitor: Defined RSSI threshold for cellular connection is bad to re-link. Network Service: Defined duration of LTE link lost, is bad to re-link.
Page 49
EW50-V Industrial LTE Cellular Gateway Packet Level Checking: According to setting with payload traffic. This will leverage some fee but tiny. Ping Packet: Defined Ping target IP and Packet size to judge link lost. DNS Lookup: Defined DNS lookup packet to judge link lost. Http(s): Defined URL http or https packets with no response to judge link lost.
Page 50
EW50-V Industrial LTE Cellular Gateway Recovery Sequency Once meet Checking method, then, recovery the cellular link, this session defined how to recovery and sequency. Once all recovery sequence run up, the system will stop to relink, user can check from LTE led and System Log.
Page 51
EW50-V Industrial LTE Cellular Gateway AT Debug User can issue general AT command to cellular modem. Advanced user who knows the AT command to check modem status. Due to resource conflict easily, we strong recommended don’t do this.
Page 52
EW50-V Industrial LTE Cellular Gateway 4G RSSI Log Once Click Download, it shows cellular link information, this is helpful for evidence. Example: 2024-09-30 08:07:14 INFO RSSI: -55 dBm 2024-09-30 08:08:14 INFO RSSI: -55 dBm 2024-09-30 08:09:14 INFO RSSI: -55 dBm 2024-09-30 08:10:14 INFO CWAN's IP is changed.
EW50-V Industrial LTE Cellular Gateway Ethernet WAN This session is for Ethernet WAN related. If the Port Switch does not specified WAN, then, it will show like this. If the Port Switch specified to WAN, it will show more setting session. There are 3 sessions here.
Page 55
EW50-V Industrial LTE Cellular Gateway Basic Settings Web Access: This specified WAN interface is Accept/Reject for internet Access from this WAN interface. Connection Type: There are 3 types of WAN connection type. Static IP setting User specified IP address, Network mask, Gateway, and DNS for Wired WAN interface. DHCP Client EW50-V WAN interface play DHCP role, waiting for IP assigned from external DHCP server.
Page 56
EW50-V Industrial LTE Cellular Gateway PPPoE Point to Point Protocol over Ethernet, you can get information from fixed wired service provider.
Page 57
EW50-V Industrial LTE Cellular Gateway WAN Guarantie Link This session is setting for keep WAN always on. Not enable, will not check anything. Once enable Gualantie Link, set for followed: Check Rules: Can checking response from Ping packets or DNS Query packets. Checking Target: Specified which target machine or IP.
EW50-V Industrial LTE Cellular Gateway WAN Redundancy Policy There are 4 Operation mode: Off: Always On: Fail Over: Fail Back: Operation Mode = Off There is only one WAN interface. Operation Mode = Always On Always On over Primary WAN, which select E-WAN or C-WAN.
Page 59
EW50-V Industrial LTE Cellular Gateway Operation Mode = Fail Over Once Fail, switch over to another WAN. Just start from Primary WAN. Payload Check Rules: Can checking response from Ping packets or DNS Query packets. Checking Target: Specified which target machine or IP. Checking Period: There are 3 parameters, Polling Times: in regular, how often to check target, by second.
Page 60
EW50-V Industrial LTE Cellular Gateway Operation Mode = Fail Back Once Fail, switch over to another WAN, watching primary WAN simultaneously, Once Primary WAN is up, then, switch Back to Primary WAN. This means default GW will switch to new one. Payload Check Rules: Can checking response from Ping packets or DNS Query packets.
EW50-V Industrial LTE Cellular Gateway General Set LAN IP address and Network Mask. Default IP is 192.168.123.254 and Network Mask is 255.255.255.0...
Page 62
EW50-V Industrial LTE Cellular Gateway DHCP Server DHCP server enable, specified DHCP IP pool and Lease expired time. The Subnet of IP will auto change once IP subnet is changing, for example, IP set to 192.168.124.256, then, the DHCP IP pool will be from 192.168.124.100 to 192,168,124.250.
EW50-V Industrial LTE Cellular Gateway Port Forwarding Port Forwarding is for external traffic from WAN interface with port to Forward to Local LAN interface with port. The Port is layer 3, Transport layer. The Interface will appear when VPN is setting and disappear when VPN are disable. Regular it shows C-WAN (Cellular WAN) and E-WAN (Ethernet WAN).
Page 65
EW50-V Industrial LTE Cellular Gateway Once Enable and click “+” for adding rule, it shows: Incoming Interface: Specified traffic from interface, VPN interface will appear when VPN enable. Forwarding Interface: Specified traffic forward to interface, VPN interface will appear when VPN enable.
Page 66
EW50-V Industrial LTE Cellular Gateway 2 examples, Port forwarding all port traffic between VPN server and LAN: Port Forwarding traffic from LAN to OpenVPN Server, which is any IP, any port and keep original port. Port Forwarding traffic from OpenVPN Server to LAN, which is any IP, any port and keep original port.
EW50-V Industrial LTE Cellular Gateway Firewall General By default, disable Firewall setting, once enable, the following IP filter and MAC filter will take effect.
EW50-V Industrial LTE Cellular Gateway IP Filter IP Filter type: Select followed rule for either one, Black List or White List. Once select List, all rules are under the list, for example, check Black List, then, all rules are for Black List.
EW50-V Industrial LTE Cellular Gateway MAC Filter MAC Filter type: Select followed rule for either one, Black List or White List. Once select List, all rules are under the list, for example, check Black List, then, all rules are for Black List.
EW50-V Industrial LTE Cellular Gateway Static Route By default, it’s disable. User can check it to enable and add rule. Once add for setting routing rule.
EW50-V Industrial LTE Cellular Gateway 3.3 Authentication Authentication is a fundamental element of secure communication. The X.509 authentication method relies on certificates to ensure that the “correct” partners communicate with each other, and that no “incorrect” partner is involved in communication. Certificate A certificate is used as proof of the identity of the certificate owner.
EW50-V Industrial LTE Cellular Gateway Machine Certificates Certificates can be used to identify (authenticate) oneself to others. The certificate used by the EW50- V to identify itself to others shall be referred to as the “machine certificate” here, in line with Microsoft Windows terminology.
EW50-V Industrial LTE Cellular Gateway CA Certificates CA certificates provide a way of checking whether the certificate shown by the peer is really signed by the CA specified in the peer’s certificate. CA certificates are certificate issued by a certification authority (CA). CA certificates are used to check whether the certificates shown by peer are authentic.
EW50-V Industrial LTE Cellular Gateway Remote Certificates A Certificate is used to verify both sides are the individual they identify themselves as. As there are two communication partners. The process takes place: partner A shows their certificate to their peer, partner B;...
EW50-V Industrial LTE Cellular Gateway CRL stands for Certificate Revocation List The CRL is a list containing serial number of blocked certificates. This is used for the configuration of sites from which the EW50-V should upload CRLs in order to use them. A CRL with the same issuer name must be present for each issuer name specified in the certificates to be checked.
EW50-V Industrial LTE Cellular Gateway 3.4 VPN VPN support OpenVPN and IPsec, as main menu. OpenVPN could config to Server role and Client role. IPsec could config to Initiator role and Responder role.
EW50-V Industrial LTE Cellular Gateway OpenVPN OpenVPN is one of popular VPN and securable for application. In order for completed VPN networks, there are 4 steps to do: step, decide interface, Cellular WAN or Ethernet WAN for OpenVPN. step, decide and well ready for Certificated files, which is in Authentication.
Page 79
EW50-V Industrial LTE Cellular Gateway Take a OpenVPN Client example figures for 4 steps completed. Port Forwarding for VPN to LAN both ways.
EW50-V Industrial LTE Cellular Gateway Overview In this session, Shows the OpenVPN connection status information when completed settings. Server Role OpenVPN Client list, shows Connection information with updated timestamp. Common Name: which is in CN base to indicate which OpenVPN client. Ex: Client Real Address: It shows WAN IP with port which comes from OpenVPN client side.
Page 81
EW50-V Industrial LTE Cellular Gateway Client Role OvpnClient1 is name of OpenVPN. Tunnel: Tunnel IP for this OpenVPN client. Remote Host: Open VPN Server side IP and port.
EW50-V Industrial LTE Cellular Gateway For OpenVPN Client Role. Basic Enable OpenVPN Service and decide OpenVPN Client role.
Page 83
EW50-V Industrial LTE Cellular Gateway Connection Click + to Add Enable: Check for enable this rule. Name: Naming for this rule Remote Host: input IP address of OpenVPN server public IP. Remote Port: Port of OpenVPN server, default port is 1194. Remote Protocol: UDP or TCP Remote CA Certificate: Assign alias name of CA Certificates in Certificate sub menu.
Page 84
EW50-V Industrial LTE Cellular Gateway Authentication for Username & Password Example, Setting complete for Connection.
Page 85
EW50-V Industrial LTE Cellular Gateway Advanced Enter Advanced page. Select VPN Name will show 3 items. Pre shared Key Click to input key.
Page 86
EW50-V Industrial LTE Cellular Gateway Remote Network Access Click + to add, take example to set Remote Subnet means server-side subnet. Once add, in this page to Save...
Page 87
EW50-V Industrial LTE Cellular Gateway Failover It sets for Once Fail, then, failover to next one, which is another OpenVPN server. + Add...
EW50-V Industrial LTE Cellular Gateway OpenVPN Server Role Basic Enable service and decide role: Server Role.
Page 89
EW50-V Industrial LTE Cellular Gateway Connection Setting for Connection parameters for OpenVPN server listen port, protocol, certificated related files and client authentications. Virtual networking interface is in Tunnel, TUN device only. Listen Port: OpenVPN server listen port, default is 1194. Local Protocol: UDP and TCP, default is UDP.
Page 90
EW50-V Industrial LTE Cellular Gateway X509 Certificate – Input Common Name of certificate of OpenVPN client side. Click + for adding. Input Common Name and Add. This example is Client. Save and apply to take effect.
Page 91
EW50-V Industrial LTE Cellular Gateway Account/Password – User set account and password for authentication. Click + for input. After add, then, save and apply to take effect.
Page 92
EW50-V Industrial LTE Cellular Gateway Advanced There are CCD and Pre shared Key for input.
Page 93
EW50-V Industrial LTE Cellular Gateway Client Config Directive, based on OpenVPN definition, user can set related command. Most popular is “iroute”, which is setting for tell Open VPN server what subnet in Open Client side. The second one is “push”, which is pushing setting to OpenVPN client side, the benefit is: OpenVPN client side no longer to set, just followed OpenVPN setting.
Page 94
EW50-V Industrial LTE Cellular Gateway Pre-shared Key There are 3 choices, None, TLS auth key and TLC crypt key. User can import key file to click icon and save.
EW50-V Industrial LTE Cellular Gateway IPSec IPSec is one of popular VPN and securable for application. In order for completed VPN networks, there are 4 steps to do: step, decide interface, Cellular WAN or Ethernet WAN for OpenVPN. step, decide and well ready for Certificated files, which is in Authentication.
Page 96
EW50-V Industrial LTE Cellular Gateway Take an IPSec Initiator example figures for 4 steps completed. Port Forwarding for VPN to LAN both ways.
EW50-V Industrial LTE Cellular Gateway Overview In this session, Shows the IPSec connection status information when completed settings. Responder Role Virtual IP Pools: Tunnel IP subnet Listening IP address: IP address list for connected. Connection: shoes the local site and remote site certificate information including common name, child for subnet for LAN, WAN and Tunnel.
Page 98
EW50-V Industrial LTE Cellular Gateway Initiator Role Listening IP address: shows local side IP address list. Connections: Show the remote side about certificate information and IP; the last line 10.0.1.1 is tunnel IP of Initiator side, user can check this for connection successful.
Page 101
EW50-V Industrial LTE Cellular Gateway Name: Naming for this rule. Remote Host: fill IP address of IPSec Responder. Remote Certificate: Selected from Alias Name of Remote Certificates of Authentication menu. Local Certificate: Selected from Alias Name of Machine Certificates of Authentication menu. Type: select one of connection type, Site-To-Site or Host-To-Host.
Page 102
EW50-V Industrial LTE Cellular Gateway Site Subnet settings Choose Connection is based on name of General settings with saved. Click + to add parameters. Set both side subnet.
EW50-V Industrial LTE Cellular Gateway For Responder Role Basic Enable IPsec Service and select role to Responder, then, save.
Page 104
EW50-V Industrial LTE Cellular Gateway Connection In this session, decide Name, Certificate, type and subnet. Responder Name: Naming for this rule. Local Certificate: Selected from Alias Name of Machine Certificates of Authentication menu.
Page 105
EW50-V Industrial LTE Cellular Gateway Allowed Initiator There could be many Initiators to Responder. Click + to add Initiator rule. Remote Certificate: Selected from Alias Name of Remote Certificates of Authentication menu. Type: select one of connection type, Site-To-Site or Host-To-Host. For example:...
Page 106
EW50-V Industrial LTE Cellular Gateway Site Subnet Decide both side subnet, based on name of Remote Certificate. Add, this example is 192.168.123.0/24 for Responder, 192.168.124.0/24 for Initiator. Click to take effect.
EW50-V Industrial LTE Cellular Gateway 3.5 Cloud This chapter support Cloud related profile setting. any Service or Application which needs cloud, can link this profile index to work. Sub menu for Cloud is Generic MQTT, Azure IoT and AWS IoT Core...
EW50-V Industrial LTE Cellular Gateway Generic MQTT Enter Generic MQTT page, you can see profile list and setting content. Edit or Add to setting. Delete the setting. Maximum rule is 15.
Page 109
EW50-V Industrial LTE Cellular Gateway Parameters Description Check to enable this profile. Enable Specified IP address or FQDN name of MQTT Broker. Broker Host TCP port of MQTT Broker: Broker Port 1883 is for none-security, 8883 port is for authentication TLS. To Enable SSL/TLS or not Specified CA Certificate profile, which is from CA Broker CA Certificate...
Page 110
EW50-V Industrial LTE Cellular Gateway 1 - at least once, 2- exactly once Retained Retained messages with Check Yes or No. Keep Alive Interval Specified keep alive between MQTT client and broker, in seconds. Default is 60 seconds Data Compression Compression by gzip or no compression, note: this has to same both sides.
EW50-V Industrial LTE Cellular Gateway Azure IoT For Microsoft Azure cloud, it supports IoT Hub Connection String, Azure IoT Hub Device Provisioning Service (DPS) and IoT Central. IoT Hub This is mapping to Azure IoT Hub service in Azure cloud.
Page 112
EW50-V Industrial LTE Cellular Gateway Once select X509 Parameters Description Check to enable this profile. Enable Check for input Connection String from IoT Hub Use Connection String service. Then, you don’t need to fill Hub Name, Device ID and Symmetric Key. IoT Hub Name from IoT Hub service Hub Name Device ID from IoT Hub device management...
Page 113
EW50-V Industrial LTE Cellular Gateway Specified CA Certificate profile, which is from CA Certificates of Certificate of Authentication menu. For X.509; Specified Local Certificate profile, which is Machine Certificate from Machine Certificates of Certificate of Authentication menu. It’s P12 PKCS#12 format. Data Push Interval Right away: Publish Messages right away once data logger available for publish.
EW50-V Industrial LTE Cellular Gateway This is mapping to Azure IoT Hub Device Provisioning Service in Azure cloud. Click + Parameters Description Check to enable this profile. Enable ID Scope from Azure DPS service ID Scope Registration ID from Azure DPS service Registration ID Device ID from Azure DPS Device ID...
Page 115
EW50-V Industrial LTE Cellular Gateway For X.509; keep it blank. Machine CA Certificate Specified CA Certificate profile, which is from CA Certificates of Certificate of Authentication menu. For X.509; Specified Local Certificate profile, which is Machine Certificate from Machine Certificates of Certificate of Authentication menu.
EW50-V Industrial LTE Cellular Gateway Central This is mapping to Azure IoT Central Service in Azure cloud. Click + Parameters Description Check to enable this profile. Enable Keep it blank for IoT Central. Application Name ID Scope from Azure IoT Central service ID Scope Device ID from Azure IoT Central service Device ID...
Page 117
EW50-V Industrial LTE Cellular Gateway Model ID from Azure Service, Options Model ID Select Individual or Group by user Azure IoT Central Enrollment Check SAS or X.509 Attestation For SAS, input symmetric key Symmetric Key For X.509; keep it blank. Machine CA Certificate Specified CA Certificate profile, which is from CA Certificates of Certificate of Authentication menu.
EW50-V Industrial LTE Cellular Gateway AWS IoT Core For Amazon Web Service AWS cloud. It supports IoT Core for IoT portal. Submenu Click +...
Page 119
EW50-V Industrial LTE Cellular Gateway As AWS IoT Core: Parameters Description Check to enable this profile. Enable Copy from AWS IoT Core service Broker Host 8883 port is always for AWS IoT Core Broker Port Keep it Yes for AWS IoT Core Original CA file copy from AWS IoT Core.
Page 120
EW50-V Industrial LTE Cellular Gateway Retained Keep it “No” for AWS IoT Core. Keep Alive Interval Keep it in default. Specified keep alive between MQTT client and broker, in seconds. Default is 60 seconds Data Compression Keep it in “No” for AWS IoT Core. Data Push Interval Right away: Publish Messages right away once data logger available for publish.
EW50-V Industrial LTE Cellular Gateway Port Connection Physical Port setting cover LAN port, COM port and Simulator for DI and DO. Filed LAN port profile defined: LAN1 and LAN2. There is no need setting. Field serial COM port defined in RS-485. EW50-V support two serial RS-485 port which indicate S1 and S2.
EW50-V Industrial LTE Cellular Gateway TCP Transparent COM port can do for TCP transparent mode, that is Serial to TCP transparent connection. Below shows Serial to TCP Server mode and Serial to TCP Client mode. Transparent TCP server mode, set listen port to waiting for TCP client to connect.
Page 125
EW50-V Industrial LTE Cellular Gateway Transparent TCP Client mode, set Remote Host and Port for TCP server role to connect.
EW50-V Industrial LTE Cellular Gateway Simulator Simulator check for DI status and drive DO high or Low. Just click the icon Click “Test DI” and result: Click “Test DO High” and result: Click “Test DO Low” and result:...
EW50-V Industrial LTE Cellular Gateway Modbus Setting for all Modbus protocol related parameters There are several views to set for Modbus protocol. RTU: Modbus RTU role which play Modbus RTU Master and Modbus RTU Slave. TCP: Modbus TCP role which play Modbus TCP Master and Modbus TCP Slave. Tag: Setting data model of Modbus protocol parameters.
EW50-V Industrial LTE Cellular Gateway Define profile for Modbus RTU Master and Modbus RTU Slave role. System all auto assign Alias Name for later setting. Master Click+ icon for Edit. Enable: Check to enable this setting, uncheck to disable Alias Name: Have a name, suggest to naming “rm1”, stands for Modbus RTU Master Number 1. Serial Profile: Select profile, which saved in COM of Port Connection.
Page 129
EW50-V Industrial LTE Cellular Gateway Click and click blinking (new data input) , it will show what you are setting: Click to take effects. Click to complete.
Page 130
EW50-V Industrial LTE Cellular Gateway Slave Click + for Edit. Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a name, suggest to naming “rs1”, stands for Modbus RTU Slave Number 1. Serial Profile: Select profile, which saved in COM of Port Connection. Click Add to add this profile.
Page 131
EW50-V Industrial LTE Cellular Gateway Click and click blinking (new data input) , it will show what you are setting: Click to take effects. Click to complete.
EW50-V Industrial LTE Cellular Gateway Define profile for Modbus TCP Master and Modbus TCP Slave role. Master Click Edit or Add, can setting all fields.
Page 133
EW50-V Industrial LTE Cellular Gateway Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a name, suggest to naming “tm1”, stands for Modbus TCP Master Number 1. LAN Profile: Select LAN port insert for Modbus TCP device. Remote Server IP: IP address of Modbus TCP device.
Page 135
EW50-V Industrial LTE Cellular Gateway Slave Modbus TCP Slave role. Click + for Add Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a name, suggest to naming “ts1”, stands for Modbus TCP Slave Number 1. LAN Profile: Select LAN port insert for Modbus TCP device. Listen Port: TCP listen port for Modbus TCP protocol.
Page 136
EW50-V Industrial LTE Cellular Gateway Take effect in system, followed the steps:...
EW50-V Industrial LTE Cellular Gateway Tag name is defined Data Model of Modbus protocol. It’s all for Modbus Master role, due to it is designed for ask Modbus data. Click + for edit. Tips for Tag Naming Rule • Tag Name with sign: –...
Page 138
EW50-V Industrial LTE Cellular Gateway Enable: Check to enable this setting, uncheck to disable. Tag Name: Have a name for this rule, suggest to naming a meaningful, for later setting, for example: ACV_R, ACV_S, ACV_T, R phase of ACV, S phase of ACV, T phase of ACV. Master Profile: Select profile from Modbus Master list.
Page 139
EW50-V Industrial LTE Cellular Gateway Float Floating Point. Double Double Floating Point. ASCII ASCII code. BITMAP Bit map in binary. STR32 String based. String String based. RAW format in Hexa. Byte Order: Based on Modbus device, select a suitable one, there are 4 types: Big Endian, Little Endian, Big Endian Byte Swap,...
Page 140
EW50-V Industrial LTE Cellular Gateway Take example: Slave ID 4: for Temperature, which is in holding register address 0, data is unsigned 16 bits and 2 decimal point. For Humidity, which is in holding register address 1, data is unsigned 16 bits and 2 decimal point. Slave ID 5: for 25, which is in holding register address 0, data is unsigned 16 bits.
EW50-V Industrial LTE Cellular Gateway Gateway Modbus GW setting, can specified followed scenario:...
Page 142
EW50-V Industrial LTE Cellular Gateway Modbus GW, from TCP to RTU Add and Edit specified: Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a name, suggest to naming “mbgw_T2R”, stands for Modbus Gateway from TCP to RTU.
Page 143
EW50-V Industrial LTE Cellular Gateway Take effect in system, followed the steps:...
Page 144
EW50-V Industrial LTE Cellular Gateway Modbus GW, from RTU to TCP Click + to Add. Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a name, suggest to naming “mbgw_R2T”, stands for Modbus Gateway from RTU to TCP.
Page 145
EW50-V Industrial LTE Cellular Gateway Response Timeout: Define command response timeout value, default is 1000ms. Click Add/Modify for this profile. Take effect in system, followed the steps:...
Page 146
EW50-V Industrial LTE Cellular Gateway Modbus GW, from RTU to RTU Click + for this profile. Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a name, suggest to naming “mbgw_R2R”, stands for Modbus Gateway from RTU to RTU.
Page 147
EW50-V Industrial LTE Cellular Gateway RTU Master Profile: Select profile for Modbus RTU Master. Response Timeout: Define command response timeout value, default is 1000ms. Click Add/Modify for this profile. Take effect in system, followed the steps:...
Page 148
EW50-V Industrial LTE Cellular Gateway Modbus GW, from TCP to TCP Click + for add this profile. Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a name, suggest to naming “mbgw_T2T”, stands for Modbus Gateway from TCP to TCP.
Page 149
EW50-V Industrial LTE Cellular Gateway Response Timeout: Define command response timeout value, default is 1000ms. Click Add/Modify for this profile. Take effect in system, followed the steps:...
EW50-V Industrial LTE Cellular Gateway MQTT Offer MQTT API, detailed information, please check API document. Disable MQTT API. Enable MQTT API, need to Edit rule. Enable: Check to enable this setting, uncheck to disable. Cloud Profile: Select cloud setting profile, which is defined from Cloud. MQTT_ID_Nick_Name: Add this field to topic for identifying which EW50-V.
EW50-V Industrial LTE Cellular Gateway Remote Control Purpose of Remote Control is defined a MQTT message format, user can control (Digital Output) Modbus Slave Devices, also provide option for acknowledge messages from controlled devices, Modbus Slave devices. Offer Remote Control API, which is over MQTT messages mechanism for both way via acknowledge messages, and messages is in JSON format.
Page 156
EW50-V Industrial LTE Cellular Gateway Example for CMD messages: • {“DO” : 1, “VALUE”: “ON”} // DO is On • {“DO” : 1, “VALUE”: “OFF”} // DO is Off • Modbus TCP • {“MODBUSTCP” : “192.168.123.100:502”, “VALUE”: “110600010003”} • Modbus RTU •...
Page 157
EW50-V Industrial LTE Cellular Gateway From Web Console, Disable Remote Control Enable Remote Control as followed: Remote Control Enable: Check to enable this setting, uncheck to disable. Cloud Profile: Select cloud setting profile, which is defined from Cloud. Response Timeout: Timeout value for controlled device response time, it’s useful for Modbus devices. Subscribe Topic: MQTT topic setting for Subscribe, which to receive command messages.
EW50-V Industrial LTE Cellular Gateway Smart Data logger Smart Data Logger is designed for proactive collect edge data, which is from Modbus devices, and push edge data to specified 2 clouds, which is MQTT, Azure Cloud and AWS cloud. Moreover, it also supports user specified uplink messages content via Tag variable, typical is in JSON format.
EW50-V Industrial LTE Cellular Gateway General In general page, it’s for enable /disable this Smart Data Logger service. Once enable. Storage for Internal (100MB) – This option is for short term demo test, and data will be over right once almost full.
EW50-V Industrial LTE Cellular Gateway Proxy Mode Proxy to take edge data via Modbus Tag, processing data and pushing data via Cloud profile. Edge Data is specified Modbus Tag, Sampling Condition and Cloud Setting. Once start click + to edit. Modbus Tag, this is for user friendly, click to list Modbus tag which is in Modbus page.
Page 161
EW50-V Industrial LTE Cellular Gateway Edge Data Click to add/modify There are 3 steps for setting: Step 1 Enable: Enable this rule Sampling Condition: Period: Setting edge data collecting period to data logger. Default is 1000ms (1 sec). Once Change: by percentage, setting edge data to data logger, once over/under setting percentage than last polling, which is setting in Modbus Tag.
Page 162
EW50-V Industrial LTE Cellular Gateway From next step, based on four tags for message format defined, in JSON is most popular. Next: click for next step.
Page 163
EW50-V Industrial LTE Cellular Gateway Step 2 Setting for 1 cloud and messages format. Cloud: setting for 1 cloud up link. Cloud Profile: Select profile form Cloud Settings page. Topic1 Publish Topic: Setting for Publish Topic for MQTT cloud only. Tag Value Display: Define tag variable form.
Page 165
EW50-V Industrial LTE Cellular Gateway Step 3 Same as concept of Step 2, just specified another cloud and different message content. If no 2 cloud required, just click Add to save step.
Page 166
EW50-V Industrial LTE Cellular Gateway Once all done, Save these settings. Take effect in system, followed the steps: Then, if Modbus RTU device, you will see S1 or S2 blinking, which is Tx and Rx interactive, besides, MQTT will show messages you are setting in every second. Temperature is 27.46-degree, Humidity is 47.02%, PM2.5 is 0, PM10 is 0.
EW50-V Industrial LTE Cellular Gateway Monitor Mode Set for Monitoring Modbus Data flow. There are 3 steps to set.
Page 168
EW50-V Industrial LTE Cellular Gateway Edge Data Enable: Enable this rule Sampling Condition: Period: Setting edge data collecting period to data logger. Default is 1000ms (1 sec). Once Change: by percentage, setting edge data to data logger, once over/under setting percentage than last polling, which is setting in Modbus Tag.
Page 169
EW50-V Industrial LTE Cellular Gateway User defined: Click this area, user start to define message content. Click left blue rectangle will copy to edit area.
Page 170
EW50-V Industrial LTE Cellular Gateway Cloud Settings For this Monitor mode, how to uplink to cloud profile. Data Push Interval Right Away: Once received edge data, then, up link data content right away. User Defined: Once received edge data, then, period duration to uplink data by minute level. Link Los Retransmit: Once uplink connection lost, re-uplink the un uplink data by delay time.
EW50-V Industrial LTE Cellular Gateway Data Viewer You can multi select items, execute to view content. By clicking title, can sorting by selection. Original...
EW50-V Industrial LTE Cellular Gateway Event Engine Event Engine is an idea to realize from Event Trigger to drive Action Behavior. Main menu as: The sequence flow we can define we called it Rule. Every rule has 3 steps. step, Event Trigger: define what is event and event format. Normally, it’s a READ or DETECTION. step, Once Event happened, delay to go or do it right away, does it need Once or Repeatedly, any other combination OR logical.
EW50-V Industrial LTE Cellular Gateway Trigger Profiles For event trigger purpose, profile list for complicated parameters input.
Page 175
EW50-V Industrial LTE Cellular Gateway Specified event trigger for what SMS content and calling from what mobile phone number is. Click Add / modify icon to edit. Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a meaningful name, ex: naming “t_sms1”, stands for Trigger for rule.
Page 176
EW50-V Industrial LTE Cellular Gateway Take effect in system, followed the steps:...
Page 177
EW50-V Industrial LTE Cellular Gateway Modbus Specified Modbus Tag event trigger for Modbus Read content with comparison operation. Click Add / Modify icon to edit. Click to show configuration what Modbus tag list. T_H and WaterLevel tags in this example.
Page 178
EW50-V Industrial LTE Cellular Gateway Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a meaningful name, ex: naming “t_mb1”, stands for Trigger for Modbus rule. Modbus Tag: Select from tag list which system bring it up automatically. Comparison: Comparison rule defines, with a compared value (in decimal).
Page 179
EW50-V Industrial LTE Cellular Gateway MQTT Notification Specified event trigger for MQTT Notified messages content. Click Add / Modify icon to edit. Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a meaningful name, ex: naming “t_mqtt1”, stands for Trigger for MQTT notification rule.
Page 180
EW50-V Industrial LTE Cellular Gateway Take effect in system, followed the steps:...
Page 181
EW50-V Industrial LTE Cellular Gateway PING Specified event trigger via Ping command to host every 10 seconds with rules. Click Add / Modify icon to edit.
Page 182
EW50-V Industrial LTE Cellular Gateway Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a meaningful name, ex: naming “t_ping1”, stands for Trigger for Ping a remote host to check in rule. Remote Host: specified remote host IP address. Trigger Type: there are 2 fields.
Page 183
EW50-V Industrial LTE Cellular Gateway Take effect in system, followed the steps:...
Page 184
EW50-V Industrial LTE Cellular Gateway RSSI Specified event trigger via RSSI (Received Signal Strength Indicator) level defined. Click Add / Modify icon to edit. Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a meaningful name, ex: naming “t_rssi1”, stands for Trigger for rssi detection rule.
Page 185
EW50-V Industrial LTE Cellular Gateway Take effect in system, followed the steps:...
EW50-V Industrial LTE Cellular Gateway Action Profiles For Action behavior purpose, profile list for complicated parameters input.
Page 187
EW50-V Industrial LTE Cellular Gateway Specified action behavior for SMS, which is specified target phone number send to and content. Besides, System provides a new FW update notification mechanism, once enable, user received SMS, then, just send the OTP (One Time Password) code to accept FW upgrade automatically. Click Add or modify icon to edit.
Page 188
EW50-V Industrial LTE Cellular Gateway Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a meaningful name, ex: naming “a_sms1”, stands for Action for rule. SMS Phone Number: Specified phone number to sending SMS. SMS Content: Specified what SMS content to send. Firmware Release Notification: User Defined: User define the notify message contents.
Page 189
EW50-V Industrial LTE Cellular Gateway For “Firmware Release Notification”. For User defined: Take effect in system, followed the steps:...
Page 191
EW50-V Industrial LTE Cellular Gateway Email Specified email server and content related information. There are 2 sessions to config: SMTP Server: Specified Email server parameters. Remote Email Profile: Specified action behavior for email send to and contents.
Page 192
EW50-V Industrial LTE Cellular Gateway Edit SMTP Server Transmission Control Protocol port number Note: SMTP servers commonly use the 25 (between servers) and 587 (for submission from authenticated clients), both with and without encryption. Alias Name: Have a meaningful name, ex: naming “emailS1”, stands for email Server rule.
Page 193
EW50-V Industrial LTE Cellular Gateway Edit Remote Email Profile Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a meaningful name, ex: naming “a_email1”, stands for Action for email rule. Remote Email: Fill sending email address. Email Content: Specified what Email content to send. Click Add /Modify for this profile.
Page 195
EW50-V Industrial LTE Cellular Gateway Specified action behavior for DO (Digital Output) to drive external device via voltage. It can select for pulse or level. Click add/modify for edit. Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a meaningful name, ex: naming “a_do1”, stands for Action for rule.
Page 196
EW50-V Industrial LTE Cellular Gateway Take effect in system, followed the steps:...
Page 197
EW50-V Industrial LTE Cellular Gateway Modbus Specified action behavior for Modbus Write to control. Click Add /Modify icon to edit. Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a meaningful name, ex: naming “a_mb1”, stands for Action for Modbus in rule.
Page 198
EW50-V Industrial LTE Cellular Gateway Assignment: Assigned value of the tag. Click Add /Modify for this profile. Take effect in system, followed the steps:...
Page 199
EW50-V Industrial LTE Cellular Gateway MQTT Publish Specified action behavior for MQTT publish messages. Click add/modify icon to edit. Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a meaningful name, ex: naming “a_mqtt1”, stands for action to MQTT publish messages in...
Page 200
EW50-V Industrial LTE Cellular Gateway Take effect in system, followed the steps:...
Page 201
EW50-V Industrial LTE Cellular Gateway LINE Notification Specified action behavior for LINE Notify to send messages. Click Add / Modify icon to edit. Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a meaningful name, ex: naming “a_LINE1”, stands for action to LINE Notify messages in...
Page 202
EW50-V Industrial LTE Cellular Gateway Take effect in system, followed the steps:...
EW50-V Industrial LTE Cellular Gateway LINE Notify Settings To enable LINE Notify service for EW50-V to LINE Notify capability. Enable it and copy Token from LINE via Generate token of LINE Notify setting page. The entry is: https://notify-bot.line.me Based on https://notify-bot.line.me, to generate Token, Steps are: 1.
Page 205
EW50-V Industrial LTE Cellular Gateway Step 1 Enable: Check to enable this setting, uncheck to disable. Alias Name: Have a meaningful name, ex: naming “ee_rule1”, stands for Event Engine Rule specified in NO1. Trigger Count: Select number of Trigger Catalog. Maximum is 3, which is OR logical, means either one trigger.
Page 207
EW50-V Industrial LTE Cellular Gateway Trigger Catalog with Profile specified: SMS, Modbus, MQTT Notification, PING and RSSI You will see profile list to select, once you set in previous profile menu page. Each catalog owned its profile definition. SMS: Received SMS text. Modbus: Modbus read value.
Page 208
EW50-V Industrial LTE Cellular Gateway Trigger Catalog with Status specified: DI, WAN Status, LAN status, Login Status and System Status. DI: Detect Digital Input voltage. Low: Trigger by DI Low voltage detection. High: Trigger by DI High voltage detection. Trigger by WAN Status. C-WAN Link Down: Cellular Link lost.
Page 209
EW50-V Industrial LTE Cellular Gateway LAN Status: LAN port link status Link Down: LAN port link down. Link Up: LAN port link up. Login Status: Web Console Login status. Web Login Fail: Happened Web Login fail. System Status: System Status for followed: Boot Up: System booting up.
Page 210
EW50-V Industrial LTE Cellular Gateway New Firmware Release: New Firmware release been informed. This needs to combine with SMS Action profile for NEW FW Notification mechanism, which provide OTP to let user agree to FW upgrade procedure. Click Next icon to step 2.
Page 211
EW50-V Industrial LTE Cellular Gateway Step 2 Set for delay to action and times of action. Delay Second: Specified delay time to go actions. Default is 0 Action Option: Once: Just one time action even trigger condition keep. Repeat: Repeat action with specified repeat count and interval, when trigger condition keeps. Repeat Count: Once check Repeat, specified count of repeat action.
Page 212
EW50-V Industrial LTE Cellular Gateway Step 3 Specified action behaviour by Action Catalog with Profile or with Operation. Action Catalog: Select for action. Profile: Profile is under Actin Catalog. Operation: directly specified action which is no profile. Back: back to step 2 Add Rule: Add this setting in rule.
Page 213
EW50-V Industrial LTE Cellular Gateway Action Catalog with Profile specified: SMS, DO, Modbus, Email, MQTT Publish, LINE Notification. They are: Each Action Catalog owned its profile definition. SMS: Sending SMS text. DO: Active DO signal Low and High. Modbus: Modbus tag write value. Email: Sending email messages.
Page 214
EW50-V Industrial LTE Cellular Gateway Action Catalog with Operation specified: System, MQTT API and REST API System: System action for followed: System Reboot: Do system reboot. SW Reset C-WAN module: execute software reset to cellular module. HW Reset C-WAN module: execute hardware reset shot to cellular module reset pin. WAN Backup Switch: execute WAN back up switch.
Page 215
EW50-V Industrial LTE Cellular Gateway REST API function selection. REST API Disable: Disable REST API function. REST API Enable: Enable REST API function. Click Add Rule icon. Rule is setting up now: Trigger condition is under t_ping1 profile and no delay to execution action with 10 second interval, the action is under a_do1 profile.
EW50-V Industrial LTE Cellular Gateway Docker Engine Docker Engine support docker capability, user can leverage this mechanism for private function in docker. Just followed the popular container game rule. By default, is disable. Once enable Docker Engine, Docker Server IP and Port need to input to system, and Secret Token form docker management server.
EW50-V Industrial LTE Cellular Gateway Configuration It supports Export Configuration and Import Configuration. Export Configuration Export file named EW50V.config which is a none text edited file. Import Configuration, tell system overwrite LAN configuration or not.
EW50-V Industrial LTE Cellular Gateway Maintenance Firmware Local Update Local Firmware to click Choose File...
Page 224
EW50-V Industrial LTE Cellular Gateway Once upgrade completed, it will auto change to login page.
Page 225
EW50-V Industrial LTE Cellular Gateway EW-FOTA Base on EtherWAN FW OTA solution. Once Enable EW-FOTA, schedule can set, which is for Newer FW available checking and auto FW upgrade time slot. So, be careful set to your suitable time slot.
EW50-V Industrial LTE Cellular Gateway Diagnostic There are 3 diagnostic commands: Ping, Traceroute and Nslookup. Ping host Internet Protocol Is used to test the reachability of a on an (IP) network. Ping to a host and an example:...
Page 227
EW50-V Industrial LTE Cellular Gateway Traceroute command packets A diagnostic for displaying possible routes (paths) and transit delays of across Internet Protocol (IP) network. Traceroute to a host and an example:...
Page 228
EW50-V Industrial LTE Cellular Gateway Nslookup network administration command-line tool Nslookup (from name server lookup) is a for querying Domain Name System domain name address, or (DNS) to obtain the mapping between records. other Nslookup to a domain name and an example:...
4.1 New Firmware Notify via SMS and reply OTP code to Go [Scenario] Based on EW-FOTA schedule checking, once EW50-V have new FW release on EtherWAN FOTA server, EW50-V notify user via SMS; user reply via OTP (One Time Password) to execute FW upgrade right away.
Tel: +886-2-6629-8986 E-mail: info@etherwan.com.tw EtherWAN has made a good faith effort to ensure the accuracy of the information in this document and disclaims the implied warranties of merchantability and fitness for a particular purpose, and makes no express warranties, except as may be stated in its written agreement with and for its customers.
Need help?
Do you have a question about the EW50-V Series and is the answer not in the manual?
Questions and answers