  • Page 1 Operation manual English Door control DC2 de Luxe GEBA Handels und Entwicklungsgesellschaft mbH Wecostrasse 7-11 D-53783 Eitorf www.geba.net...
  • Page 2 Operation manual The DC 2 EN control is designed for the operation of gate systems. The basic version is designed for dead man's operation. Latching operation is only permitted if additional safety elements are installed. The system manufacturer is responsible for the entire system. He must ensure compliance with the relevant standards and guidelines (e.g.
  • Page 3 Operation manual Explanation pictograms CAUTION CAUTION indicates a hazard which, if not avoided, could result in injury ATTENTION ATTENTION indicates measures to avoid damage to property. INFO Designates application tips and other useful information. Technical specifications DC2 deLuxe mains connection 230VAC frequency 50Hz...
  • Page 4 Operation manual Auto-Close Functional Run Time Timer settings Settings settings External limit switches 7-Segment Buzzer Anzeige security Safety edge Status Safety circuit Power LED grün LED rot Schlupftür / Program- Schlaffseilschalter Radio Receiver Button GEBA Photocell Key Pad Membrane Push Button GEBA impulse button...
  • Page 5: Display Status

    Display Status Power LED (green) on Status LED (red) off Switch on the supply voltage, the self-test is running Ready to use If you get an error message 1 – 9, please refer to page 6 Normal Operating Status Display Status Notes Door ready for...
  • Page 6: Troubleshooting

    Troubleshooting Fault Display Display LED red Fault Cause Solution LED red Door will not operate External Stop Button Pressed Release External Stop Button after power up Release External Stop Button LED red Door will not operate External Stop Button Pressed Release External Stop Button after power up Release External Stop Button...
  • Page 7 Function DIP- Switch General functions PROG II DIP1 Not used Not used External timer * keypad / transponder See table See table Learning radio actively Learning radio deactivate Programming mode input units, keypads or transponders Relay OUT1 Message 'End position OPEN' Relay OUT1 Message 'End position CLOSED' Relay OUT1...
  • Page 8 Function DIP- Switch Running Time (RT) PROG I PROG II DIP2 DIP3 DIP4 DIP1 52“ 100“ 148“ OFF 1 2 3 4 5 6 OFF 1 2 3 4 5 6 OFF 1 2 3 4 5 6 OFF 1 2 3 4 5 6 7“...
  • Page 9 Function DIP- Switch Automatic Closing Time (CT) PROG I PROG II DIP2 DIP4 DIP3 DIP1 52“ 100“ 148“ OFF 1 2 3 4 5 6 OFF 1 2 3 4 5 6 OFF 1 2 3 4 5 6 OFF 1 2 3 4 5 6 7“...
  • Page 10: Motor Connection

    Mains connection 230V 230V Mains connection 230V N = neutral (blue) L1 = phase (brown) PE = protective earth (green/yellow) Lead the connection via an all-pole isolating main switch Motor-Connection Tubular-Motor The jumper between terminals L and C is required for a 230V tubular motor.
  • Page 11 External pushbutton DWN STOP DWN STOP Connection for a key switch without A triple push button can be a stop function connected to the push button input. The jumper at the stop input must be The jumper at the stop removed input must be removed External pull button (impulse)
  • Page 12 Input unit GEBA First connect the input unit and only then switch on the power supply DIP- 1 Programm II Switch on 1 2 3 4 5 6 programming mode Keypad Code entry (e.g.) Confirmation Display Sound Operation 1234 Schlüssel- 2 x long ▲...
  • Page 13 Code storage table Please make a note of the code for the respective storage location Storage space Code Storage space 0 Storage space 1 Storage space 2 Storage space 3 Storage space 4 Storage space 5 Storage space 6 Storage space 7 Storage space 8 Storage space 9 13 / 20...
  • Page 14 Input unit GEBA First connect the input unit and only then switch on the power supply DIP- 1 Programm II Switch on 1 2 3 4 5 6 programming mode Transponder Reader Teach-in Key Nr. Storage space Transponderkey It can store up to 10 transponder keys distributed to storage Transponderkey...
  • Page 15 Photocell Remove bridge DIP- 2 Programm I + 24 Test+ 1 2 3 4 5 6 Testing enabled Test 12 - 30 12 – 30 AC Transmitter with test input Receiver Representation in energized state Safety Input (SK) SK R = 5k SK R = 5k Slip door Roll-off...
  • Page 16 Closing edge protection The following safety edge systems can be connected directly to the door control: Optoelectronic (OSE) Electrical safety edge 8k2 The required evaluator is included in the controller (EN12435) The optoelectronic safety edge (OSE) is connected directly to the GND, SKS and 12V terminals.
  • Page 17 Radio Control GEBA The control is designed for the operation of gate systems. In the basic version it is designed for dead man's operation. Latched operation is only permitted if additional safety elements are installed. First plug in the receiver and only then switch on the power supply DIP- 1 7-Segment Programm II...
  • Page 18 Courtyard light A 230VAC lighting can be connected to the connection. Programm I 2 minutes DIP- 2 3 seconds 1 2 3 4 5 6 It is activated with every door movement (open or closed) Traffic light red internal Potential-free contact Relay pre-warning active...
  • Page 19 External limit switches If external limit switches are required, they can be connected as an normaly close (NO). The bridges must then be removed. 19 / 20...
  • Page 20 Disposal of old electronic devices in Germany Important information after Electrical and Electronic Equipment Act (ElektroG) We would like to point out to owners of old electrical and electronic equipment that old electrical equipment must be disposed of separately from municipal waste in accordance with the applicable statutory provisions.