UV Resources DLX-N-HO-120-277 General Installation Instructions

Dual lamp high output nema fixture

Advertisement

DLX-N™ – D
benefits
Dual, high output lamps
Dual, high output lamps
n
n
Perfect for airborne pathogen
Perfect for airborne pathogen
n
n
inactivation
inactivation
NEMA-4 design installs
NEMA-4 design installs
n
n
outdoors or indoors
outdoors or indoors
Easily installs to return,
Easily installs to return,
n
n
supply or exhaust ducts
supply or exhaust ducts
360° UV-C distribution
360° UV-C distribution
n
n
120-277V power supply
120-277V power supply
n
n
Integrated lamp/ballast
Integrated lamp/ballast
n
n
monitoring with BMS output
monitoring with BMS output
Chemical and ozone-free
Chemical and ozone-free
n
n
operation
operation
Improves indoor air quality
Improves indoor air quality
n
n
(IAQ)
(IAQ)
Destroys coil/drain pan
Destroys coil/drain pan
n
n
microbial growth
microbial growth
Restores AHU capacity and
Restores AHU capacity and
n
n
efficiency
efficiency
Industries lowest cost of
Industries lowest cost of
n
n
ownership
ownership
3-year fixture and ballast
3-year fixture and ballast
n
n
warranty; 1-year lamp
warranty; 1-year lamp
warranty
warranty
L
H
uaL
amp
igH
UV-C's germicidal ability to disinfect and degrade organic material is well-
established in both research and application (ASHRAE, Science, GSA and
the CDC). UV-C is the go-to technology for inactivating pathogens and
protecting occupants in indoor environments from the spread of infectious
disease.
Besides disinfecting airstreams, UV-C has decades of proven history of
keeping coils, drain pans and other internal air handler components free of
microbes, organic dirt and grime — materials that produce odor, reduce
airflow, limit cooling capacity and diminish worker productivity.
UV-C systems are widely used in commercial buildings, restaurants and
hospitals to disinfect HVAC airstreams, cooling coils and drain pans to
keep them free of microorganisms and other organic debris that reduce
airflow and limit evaporator coil heat-transfer efficiency. UV-C stops the
proliferation of infectious or allergenic agents and lowers the cost of
maintaining and operating HVAC equipment.
UV Resources' Dual Lamp high output NEMA-4 fixture (DLX-N) delivers
the necessary UV-C dose to inactivate pathogens in virtually any airstream,
while offering industry-leading performance, reliability and cost of
ownership. The DLX-N is constructed of premium materials with powder
coated heavy-gauge steel designed to withstand virtually any environment.
Power supplies are waterproof and UV-C germicidal lamps are high
output, high-efficiency, low-waste content products that surpass today's
environmental standards and available with protective FEP coating.
Application:
The DLX-N fixture meets all ASHRAE guidelines and is suitable for most
UV-C applications. Fixtures install from the exterior of HVAC equipment
or ducts to achieve the specified irradiance and dose. They can be installed
in supply, return or exhaust plenums and ducts, to disinfect moving
airstreams and/or surfaces to prevent microbial proliferation and transfer
to conditioned spaces, and to preclude the buildup of organic materials. A
variety of sizes and smart multi-voltage (120-277V) options allow for an
easy installation in nearly any application.
O
NEma F
utput
DLX-N
iXturE
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DLX-N-HO-120-277 and is the answer not in the manual?

Questions and answers

Summary of Contents for UV Resources DLX-N-HO-120-277

  • Page 1 HVAC equipment. monitoring with BMS output monitoring with BMS output UV Resources’ Dual Lamp high output NEMA-4 fixture (DLX-N) delivers Chemical and ozone-free Chemical and ozone-free the necessary UV-C dose to inactivate pathogens in virtually any airstream,...
  • Page 2: Ordering Information

    The UVR website contains tools that let you select, specify, and/or purchase complete UV-C systems. You’ll also find valuable content that will help simplify installation, operation, and maintenance of UV-C systems. Specifications subject to change without notice. For more information, go to uvresources.com © UV Resources 2021 55003523 Rev. C...
  • Page 4 NOTES: lYPICAL EXISTING 1. UL / CUL LISTED ABQK PENDING. DUCTWORK 2. FOR INDOOR & OUTDOOR USE. 3. 20 AWG GALVANIZED, ASTM-A653 / A924, POWDER COATED. MULTIPLE DLX UVC LAMP ASSEMBLY 4. ( 1 ) 1 ELECTRICAL KNOCKOUTS. LOCATED IN EXISTING DUCTWORK 5.
  • Page 5: Parts Ust

    NOTES: lYPICAL EXISTING 1. UL/CUL LISTED ABQK PENDING. DUCTWORK 2. FOR INDOOR & OUTDOOR USE. 3. 20 AWG GALVANIZED, ASTM-A653/A924, POWDER COATED. MULTIPLE DLX UVC LAMP ASSEMBLY 4. ( 1) 1 ELECTRICAL KNOCKOUTS. LOCATED IN EXISTING DUCTWORK 5. (6) MOUNTING HOLES. {SEE IOM FOR ADDITTONAL INFORMATION) 6.
  • Page 6 NOTES: lYPICAL EXISTING 1. UL / CUL LISTED ABQK PENDING. DUCTWORK 2. FOR INDOOR & OUTDOOR USE. 3. 20 AWG GALVANIZED, ASTM-A653 / A924, POWDER COATED. MULTIPLE DLX UVC LAMP ASSEMBLY 4. ( 1 ) 1 ELECTRICAL KNOCKOUTS. LOCATED IN EXISTING DUCTWORK 5.
  • Page 7 NOTES: lYPICAL EXISTING 1. UL / CUL LISTED ABQK PENDING. DUClWORK 2. FOR INDOOR & OUTDOOR USE. 3. 20 AWG GALVANIZED, ASTM-A653 / A924, POWDER COATED. 4. ( 1 ) 1 UVC LAMP ASSEMBLY ELECTRICAL KNOCKOUTS. LOCATED IN EXISTING DUClWORK 5.
  • Page 8: Side View

    MOUNTING HOLES (lYP 6) LAMP PENETRATION, lYP 2 6.4105 r- 2 : I o ------' A '------ � 14.61 14.73 9.6 2 5 �I OPTIONAL ELECTRICAL 1 /t KNOCKOUT PENETRATION SIDE VIEW TOP GASKET SUGGESTED OPTIONAL lYP ALL AROUND ELECTRICAL PENETRATION BOTTOM VIEW PLAN VIEW - COVER REMOVED NOTES:...
  • Page 9 LAMP PENETRATION, lYP 2 --6.4105-- 14.61 9.625 14.73 t> IIEII I QIYI PMr NO. I DESCRIPl 1 I 1 I 9a3B28 I ENCI.OSl BASE IIB3829 I ENCI.OSl LID 1182874 I IW.IASI" 4 I 1 I 98111148 I C U2 5 I 2 I IIB7811 14 PIN CIRCUI£ I/ill' PWG a I a I - I fB-32 PEIi SIIII 7 I 2 I aaJ683 I fB-32 UM:111£...
  • Page 10: General Installation Instructions

    DLX-N™ High Output Dual Lamp NEMA 4 UV-C Fixture GENERAL INSTALLATION INSTRUCTIONS 57806550 CAUTION! Never Expose Eyes or Skin to UV-C - Read all Materials before Starting SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause fire, electrical shock, or other conditions which may cause personal injury or property damage.
  • Page 11 Power Ratings: The DLX-N (NEMA 4) is rated for 120-277Vac 50-60Hz, single phase. NOTE: Grounding should be neutral-to-ground. ***Note: Use only ”800mA” (high output) T5 diameter, 4- pin single ended (4PSE) lamps – sizes 12” to 31” with this product*** Compliance: Underwriter Laboratories (UL) ABQK, Accessories, Air Duct Mounted.
  • Page 12 Risque d’exposition à un rayonnement ultraviolet (UV) excessif - Ne pas utiliser sans la protection complète de la lampe ou si la lentille est endommagée. Power Consumption: **NOTE: Each DLX-N Fixture uses two (2) lamps – Watts and Amps in below table are for the TWO lamp fixture*** Electrical Amps...
  • Page 13 DLX-N – Install DLX-N – Install multiple on side of multiple on both duct/AHU sides of duct/AHU Installation (designed for metal plenums only): 1. Consult all applicable codes before installing. Check fixture label(s) for the correct power requirements and supply the correct voltage from a suitable, protected (fused or breaker), and grounded power source. 2.
  • Page 14 Installing lamps Note: The DLX-N Fixture uses EncapsuLamp™ technology (FEP coated lamps) therefore you can handle the lamp and not worry about cleaning the surface. Non-FEP coated lamps can be used as an alternative. 1. Remove the “thumb nuts” and washers form the lamp mounting studs. 2.
  • Page 15: Equipment Warranty

    EQUIPMENT WARRANTY UV Resources™ (UVR) warrants to the original buyer that its Products shall be free from defects in material or workmanship under normal use and service for the periods of time set forth below. This warranty is contingent upon proper use of Products and will not apply if adjustment, repair or parts replacement is...

Table of Contents