Megohmmeter test kit

Advertisement

Quick Links

ElectraDyne -1000 Series
Megohmmeter Test Kit Manual
NOTE: THIS MANUAL IS NOT TO BE SEPARATED FROM METER
Test Electrical Resistivity and Conductance, Electrical Grounding, Point to
Point Resistance, Resistance to Ground, Temperature and Humidity.
1
United Static Control Products Inc
2124 S Prairie Ave, Building D, Pueblo, CO 81005
United States of America
Telephone (USA) 719 676 3928

Advertisement

loading
Need help?

Need help?

Do you have a question about the ElectraDyne 1000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for UNITED ElectraDyne 1000 Series

  • Page 1 NOTE: THIS MANUAL IS NOT TO BE SEPARATED FROM METER Test Electrical Resistivity and Conductance, Electrical Grounding, Point to Point Resistance, Resistance to Ground, Temperature and Humidity. United Static Control Products Inc 2124 S Prairie Ave, Building D, Pueblo, CO 81005 United States of America...
  • Page 2 9 volt long life battery Blow Molded foam lined travel case Product instructions and operation manual 10) Certificate of calibration United Static Control Products Inc 2124 S Prairie Ave, Building D, Pueblo, CO 81005 United States of America Telephone (USA) 719 676 3928...
  • Page 3 G) Input for external Electrode or ground D) Voltage Selection * NOTE: Disregard ohms/sq when using external electrodes United Static Control Products Inc 2124 S Prairie Ave, Building D, Pueblo, CO 81005 United States of America Telephone (USA) 719 676 3928...
  • Page 4 **Use only for readings above 1.0E10 ***Do not cover this sensor ****Use of these ports for external electrodes will disconnect internal electrodes United Static Control Products Inc 2124 S Prairie Ave, Building D, Pueblo, CO 81005 United States of America...
  • Page 5 Cylindrical electrode, 2.27 kg +/- 2.5% (5 lb. +/-2.5%) with a diameter of 63.5 mm +/- 5% (2.5 inches +/- 5%) having a contact of electrical conductive material with a Shore-A (IRHD) durometer hardness between 50 and 70. United Static Control Products Inc 2124 S Prairie Ave, Building D, Pueblo, CO 81005 United States of America...
  • Page 6 AND stray voltages. Both variables may cause inaccuracy when testing in the highly insulative ranges. One is supplied with each kit. Replacement cables are readily available from United SCP. B) These cables are used for external electrodes. Note: one end of these cables terminate in a pin plug, the opposite end terminates with a banana plug.
  • Page 7 Use the switch in front of the meter to change voltage setting. United Static Control Products Inc 2124 S Prairie Ave, Building D, Pueblo, CO 81005 United States of America...
  • Page 8: Temperature And Humidity

    This can cause rejects and loss of product. United Static Control Products Inc 2124 S Prairie Ave, Building D, Pueblo, CO 81005 United States of America...
  • Page 9 After one year the instrument may be sent back to United Static Control Products for testing and recertification. Please note: United is a non ISO organization. It may also be sent to an ISO certified calibration lab or done “in house” using the calibration directions supplied in this document.
  • Page 10 NOTE: Remove the banana plugs and pin jacks from the meter when not in use. Not doing so may cause a Code 20 error. United Static Control Products Inc 2124 S Prairie Ave, Building D, Pueblo, CO 81005 United States of America...
  • Page 11 Test at 100 volts for values over 1x10 ohms. 16. Tolerance from 10 ohms is 10% United Static Control Products Inc 2124 S Prairie Ave, Building D, Pueblo, CO 81005 United States of America Telephone (USA) 719 676 3928...
  • Page 12: End Of Document

    END OF DOCUMENT, For Tech support with this device or suggestions for revisions to this document please contact me direct techsupport@ultrastatinc.com © UNITED Static Control Products Inc Document History: 2.8.24: Initial release, approved SRC 7.19.24: Code 20 errors. What is the cause? Approved SRC...