Belkin P74976UKAP41000EA3M User Manual
Belkin P74976UKAP41000EA3M User Manual

Belkin P74976UKAP41000EA3M User Manual

Power console

Advertisement

Home Cinema Power Protection with PureFilter
Technology
Power Console PF50
User Manual
AP41000ea3M

Advertisement

Table of Contents
loading

Summary of Contents for Belkin P74976UKAP41000EA3M

  • Page 1 ™ Home Cinema Power Protection with PureFilter Technology Power Console PF50 User Manual AP41000ea3M...
  • Page 2: Table Of Contents

    Step 10 Connect your Cable TV/Satellite Coaxial Lines ............. 17 Step 11 Connect your Broadband Ethernet Line ..... 18 Operation ..................19 Technical Specifications ............21 Troubleshooting ................. 22 Glossary of Power Terms ............24 Belkin Connected Equipment Warranty ........25...
  • Page 3: Introduction

    Introduction Thank you for purchasing the PureAV Power Console. The Power Console is designed to clean, protect, and efficiently distribute power to your valuable home cinema system. The PureAV Power Console ensures that every movie you watch and every album you hear is as clean and clear as possible.
  • Page 4: Safety Precautions

    Failure to plug this product directly into an earthed socket may result in personal injury or damage to your equipment, and void your Belkin Connected Equipment Warranty. Call a licensed electrician if you are unsure if your AC sockets are properly earthed.
  • Page 5: Package Contents

    For more detailed information about recycling of this product, please visit our web at www.belkin.com (or contact your local city office, your household waste disposal service or the shop where you purchased...
  • Page 6: Power Console Features

    Power Console Features Switched Button - turns on and off the power to the Power Console’s “switched” sockets 2. Auxiliary Socket - offers optimal connection for digital components, ideal for temporary connection of equipment such as video/digital cameras, game consoles, or any device you wish to power 3.
  • Page 7 Power Console Features 12. Pay-Per-View/Phone-Line Input/Output - protects Pay-Per-View, phone, or DSL lines from dangerous power surges that can damage your equipment; built-in splitter turns one line into 2 13. Broadband Ethernet Input/Output - protects broadband Ethernet lines used for digital media receivers, gaming, or broadband Internet access from dangerous power surges 14.
  • Page 8: Hookup And Installation

    Hookup and Installation Step 1 Mounting your Power Console (Optional) The PureAV Power Console can be mounted to a standard AV equipment rack or inside a cabinet equipped with an equipment rack. A. Remove the mounting brackets from the box. B.
  • Page 9: Step 2 Program The Socket Banks

    Hookup and Installation Step 2 Program the Socket Banks Each socket bank on the rear panel of the Power Console PF50 is programmable. Using the slide switches on the rear panel, you can program the sockets for switched or unswitched, and for delay or always-on (no delay) (Fig.
  • Page 10 Hookup and Installation E. Trigger Out: The trigger-out function gives you the ability to control an external device equipped with a remote trigger, such as a retractable movie screen or projector, when the Power Console is switched on. The 12-volt DC “OUT” port accepts a 3.5mm jack cable.
  • Page 11: Step 3 Remote Ac Operation

    Hookup and Installation Step 3 Remote AC Operation This function allows you to turn your Power Console on and off via your preamplifier or receiver equipped with a switched European power socket. Note: You cannot turn off the switched sockets on the Power Console with the “Switched”...
  • Page 12: Step 4 Remote Dc Operation

    Hookup and Installation Step 4 Remote DC Operation This function allows you to turn your Power Console on and off via any component that is equipped with a 3~30V DC output (low-voltage trigger out). Note: You cannot turn off the switched sockets on the Power Console with the “Switched”...
  • Page 13: Step 5 Connect Digital Components To The Digital Filters

    Hookup and Installation Step 5 Connect Digital Components to the Digital Filters The PureAV Power Console PF50 has two isolated digital filters (Bank 01 and Bank 02); the isolated digital filters are optimised to clean and condition the power to all of your digital components. The digital filters also filter out noise created by digital components, such as DVD players, and isolate your digital components from connected video, audio, and high-current audio components.
  • Page 14: Step 6 Connect Video Components To The Video Filter

    Hookup and Installation Step 6 Connect Video Components to the Video Filter The PureAV Power Console contains an isolated video filter that is optimised to clean and condition the power to all of your video components. The video filter also isolates your video components from connected digital, audio, and high-current audio components.
  • Page 15: Step 7 Connect Audio Components To The Audio Filter

    Hookup and Installation Step 7 Connect Audio Components to the Audio Filter The PureAV Power Console contains an isolated audio filter that is optimised to clean and condition the power to all of your audio components. The audio filter also isolates your audio components from connected digital, video, and high-current audio components.
  • Page 16: Step 8 Connect High-Current Audio Filter

    Hookup and Installation Step 8 Connect High-Current Audio Filter The HiCurrent socket is specifically designed to filter out AC line noise while delivering maximum current to power-hungry amplifiers and other high-current audio components. Note: This socket bank should be programmed for “Delay”. This allows your high-current amplifiers to turn on last and turn off first, avoiding that annoying, and potentially damaging “thump”...
  • Page 17: Step 9 Connect Your Pay-Per-View/Phone Line

    Hookup and Installation Step 9 Connect your Pay-Per-View/Phone Line Your PureAV Power Console comes equipped with Pay-Per-View/phone- line protection with a built-in splitter. These are standard BT RJ11 phone ports and are labeled “Phone”. A. Connect one end of your telephone cable to the wall port to which you normally connect your phone line.
  • Page 18: Step 10 Connect Your Cable Tv/Satellite Coaxial Lines

    Hookup and Installation Step 10 Connect your Cable TV/Satellite Coaxial Lines Your PureAV Power Console comes with two pairs of F-type coaxial- cable connections, and one pair of aerial-cable connections to protect your system from dangerous electrical disturbances that can travel down your cable/satellite/aerial-signal lines.
  • Page 19: Step 11 Connect Your Broadband Ethernet Line

    Hookup and Installation Step 11 Connect your Broadband Ethernet Line Your PureAV Power Console comes equipped with broadband Ethernet- line protection. These are standard RJ45 Ethernet ports and they are labeled “Network”. A. Connect one end of an RJ45 network patch cable to a network port (either directly to a router or wired network wall port).
  • Page 20: Operation

    Operation Central LCD Control Panel The PureAV Power Console is equipped with an advanced LCD Control Panel. Most functions of the Power Console can be monitored from this display. A. PureFilter Indicator – shows that the multiphase PureFilter Circuitry is functioning properly. B.
  • Page 21 Operation K. Bank Selector Button – lets you select which outlet banks you want to monitor; press the button repeatedly to choose either a single bank (Fig. 5a) or all banks (Fig. 5b). L. Dimmer Button – adjusts the brightness of the LCD Control Panel; press it repeatedly to change the brightness level.
  • Page 22: Technical Specifications

    Technical Specifications Specification PF50 Electrical Rating 240V~13A/3120W Product Weight (kg.) 7.1kg. Product Dimensions (mm) 435 x 329 x 153mm (LxWxH) Number of Sockets 10 Programmable Sockets Cable Length 3M - SD1000 Joule Rating 8750J Maximum Spike Current 300,000A Response Time <1 nanosecond Coaxial Protection 3-in;...
  • Page 23: Troubleshooting

    • If the “Earth Fault” indicator is still lit, you have an earth-wiring problem. Connecting the Power Console to an improperly earthed socket is not safe and will void all Belkin warranties. Unplug the Power Console and consult an electrician to properly earth the socket.
  • Page 24 AC wall socket. Do not use any plug adapters. • This indicates that the live and neutral (L–N) wires are reversed. Unplug the Power Console and consult an electrician. For all other technical questions or troubleshooting issues, please contact Belkin Customer Service on 00 800 22355460.
  • Page 25: Glossary Of Power Terms

    Glossary of Power Terms Alternating Current (AC): The current that is commonly flowing through the electrical sockets in your home. It is an electrical current in the form of a sine wave that oscillates up and down continuously. Amp: An abbreviation for Ampere. This is a unit of electrical current. Direct Current (DC): An electrical current flowing in one direction only.
  • Page 26: Belkin Connected Equipment Warranty

    For model AP41000xx3M (PF50), up to a maximum of E400.000 The fair market value of the equipment shall be the current retail market value of the same or similar model or specification as agreed by Belkin at the time it accepts or approves any claim.
  • Page 27 In no event shall Belkin be liable for consequential or indirect losses, including lost business, loss of...
  • Page 28 Belkin Connected Equipment Warranty To file a claim against the Belkin Connected Equipment Warranty, you must take the following steps: 1. You must have an original receipt with date of purchase. 2. Contact a Belkin Limited Customer Service Representative at 00 800 22355460 within 15 days of the Occurrence.
  • Page 30 +31 (0) 20 654 7300 +33 (0) 1 41 03 14 40 +31 (0) 20 654 7349 fax +33 (0) 1 41 31 01 72 fax © 2005 Belkin Corporation. All rights reserved. All trade names are registered trademarks of respective manufacturers listed. P74976uk...

This manual is also suitable for:

Ap41000uk3mPureav pf50

Table of Contents