Charles CMPH-950DFNCU General Description And Installation

Multi-purpose housing

Advertisement

Quick Links

1.
GENERAL INTRODUCTION .......................................................... 1
1.1. Document Purpose ........................................................................ 1
1.2. Product Purpose ........................................................................... 1
1.3. Product Mounting and Location .................................................. 1
2.
PRODUCT DESCRIPTION .............................................................. 2
3.
INSTALLATION ................................................................................. 4
3.1. Inspecting the Product .................................................................. 4
3.2. Following and Using Safety Precautions .................................... 4
3.3. Obtaining Tools and Equipment .................................................. 4
3.4. Installing a New CMPH Enclosure ............................................. 5
4.
5.
WARRANTY & CUSTOMER SERVICE ........................................ 8
6.
SPECIFICATIONS .............................................................................. 8

1. GENERAL INTRODUCTION

1.1. Document Purpose

This document provides general information for the CMPH-950DFNCU multi-purpose housing. Figure 1 shows a closed front view of the
enclosure.
Hereafter, the Charles Universal Broadband Enclosure CMPH-950DFNCU will be referred to as the "CMPH."

1.2. Product Purpose

The CMPH is a non-metallic, three-piece, rectangular, OSP enclosure that offers easy installation, superior structural strength, 360⁰
technician access, generous internal equipment and cable storage capacity, and protection against corrosion, floods, fire, weather, dirt,
insects, intrusion, dents and impacts.

1.3. Product Mounting and Location

The CMPH is an above-grade enclosure. The base is typically installed in a trench or hole in the ground up to the base's ground line
indicator. The ribbed or corrugated base walls provide stability in most soil types. The 2-section dome mounts on the base and protects all
equipment installed or mounted inside the CMPH. Stake mounting is achieved by attaching a stake at the center of the interior side walls.
Detailed mounting and installation information is covered in Section 3.
©Copyright 2020 Charles Industries LLC. All Rights reserved. Printed in the United States of America.
Availability of features and technical specifications herein are subject to change without notice.
Charles is a registered trademark of Charles Industries.
Charles Multi-Purpose Housing
CMPH-950DFNCU
General Description and Installation
Figure 1
-NOTE-
LT-CMPH950DFNCU
st
1
Printing, January 7, 2020
Front View of the CMPH
Page 1 of 8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CMPH-950DFNCU and is the answer not in the manual?

Questions and answers

Summary of Contents for Charles CMPH-950DFNCU

  • Page 1: Table Of Contents

    Figure 1 Front View of the CMPH 1.1. Document Purpose This document provides general information for the CMPH-950DFNCU multi-purpose housing. Figure 1 shows a closed front view of the enclosure. -NOTE- Hereafter, the Charles Universal Broadband Enclosure CMPH-950DFNCU will be referred to as the “CMPH.”...
  • Page 2: Product Description

    LT-CMPH950DFNCU 2. PRODUCT DESCRIPTION The CMPH contains a base, a mid-section, and a dome. The base has corrugated or ribbed walls, an open top, and an open bottom. The open bottom allows replacement installations and underground cable access. Figure 2 shows the CMPH dimensions. Figure 3 shows the main components of the CMPH. Figure 2 CMPH Dimensions (in inches) Page 2 of 8...
  • Page 3 LT-CMPH950DFNCU Figure 3 CMPH Components Printing Page 3 of 8...
  • Page 4: Installation

    LT-CMPH950DFNCU 3. INSTALLATION 3.1. Inspecting the Product The CMPH is shipped mounted upright on a skid. Unpack the unit, and dispose of the packaging material. -INSPECTION NOTE- Visually inspect the unit for damages prior to installation. If the equipment was damaged in transit, immediately report the extent of the damage to the transportation company.
  • Page 5: Installing A New Cmph Enclosure

    LT-CMPH950DFNCU 3.4. Installing a New CMPH Enclosure Step Description Dig and prepare the cable trench, per company practice. Do not damage any buried cables or wires while digging. Follow company practice to lay, place, and cut any cables, interduct or conduit. Unlock the CMPH using a 216 tool or can wrench at the four cup-washer screws (two at each side of the CMPH).
  • Page 6 LT-CMPH950DFNCU Always follow local codes and company practice when preparing earth ground and when grounding cables or equipment. If an earth ground is not present at the CMPH site and local code or practice requires an earth ground, prepare one now. Attach the earth ground to the CMPH’s ground lug on the ground plate using a ground wire of proper gauge, per company practice.
  • Page 7: Installing The Cmph With Charles Mounting Stakes

    LT-CMPH950DFNCU 3.5. Installing the CMPH with Charles Mounting Stakes Step Description Perform Steps 1-8 of section 3.4 to open the enclosure and prepare the hole or trench and the cables or conduit. Verify the base installation site is ready and suitable for metallic stakes.
  • Page 8: Technical Assistance And Repair Service

    5. WARRANTY & CUSTOMER SERVICE Charles Industries LLC offers a one-year warranty on the CMPH product. The Charles warranty is limited to the operation of the CMPH hardware as described in this documentation and does not cover equipment which may be integrated by a third party. The terms and conditions applicable to any specific sale of product shall be defined in the resulting sales contract.