PELEKIS FRWD0805 User Manual

Led light controller

Advertisement

User Manual FRWD0805
LED Light Controller
Page 2 General Description - Specifications
Page 3 Connections
Page 4 Operation
Page 5 Dip Switch Settings
Page 6 Battery charging
Page 7 Battery charging curves
Please read carefully the instructions in order to
get all the benefits of this device.
REV 1.1
PELEKIS ELECTRONICS
September 12, 2021
ISO9001/2015 member
www.pelekis.eu

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FRWD0805 and is the answer not in the manual?

Questions and answers

Summary of Contents for PELEKIS FRWD0805

  • Page 1 User Manual FRWD0805 LED Light Controller • Page 2 General Description - Specifications • Page 3 Connections • Page 4 Operation • Page 5 Dip Switch Settings • Page 6 Battery charging • Page 7 Battery charging curves Please read carefully the instructions in order to get all the benefits of this device.
  • Page 2: General Description

    Weight 1100 The above numbers measured at connector MAIN. SIX PELEKIS LED lights connected to MAIN connector, and TWO PELEKIS LED lights connected to EMERGENCY connector. The battery status during measurements was 50%>BAT>25%. Current measurement was continuous DC. (Charging during CC stage at 0.1/C, aprox.130mA).
  • Page 3 Connections: The FRWD0805 device can operate in various connection setups and with variations in load combinations (using PELEKIS LED Lights). A typical connection setup consists of: FOUR INTELCO LED Lights as “MAIN” light sources, TWO PELEKIS LED Lights as “MAIN/EMERGENCY”...
  • Page 4: Operation

    Operation Normal Mode: During normal AC 230V mains operation, the FRWD0805 device will drive the 2 groups of PELEKIS LED Lights connected to “MAIN” and/or “MAIN/EMERGENCY” connectors and they remain on. The 3 group of PELEKIS LED Lights connected to “EMERGENCY"...
  • Page 5: Dip Switch Settings

    Emergency Mode: When the AC 230V mains fail, the FRWD0805 device automatically enters the Emergency Mode. The “MAIN” group of PELEKIS LED lights is now off, and the “MAIN/EMERGENCY” and “EMERGENCY” groups are on. At this mode the REMOTE” connector input is ignored and the lights will work at 100% with no dimming at all.
  • Page 6: Battery Charging

    This device uses an LED to indicate Battery status (see Table 4). Table 4 LED Activity Battery status Battery charging progress >90% BLINKING Battery charging Rate: 0.5s on progress 0.5s off 75%>BAT>50% Battery failure Battery disconnected PELEKIS ELECTRONICS ISO9001/2015 member REV 1.1 September 12, 2021...
  • Page 7 Battery Charging Curves PELEKIS ELECTRONICS ISO9001/2015 member REV 1.1 September 12, 2021...

Table of Contents