GAMPT SF610 User Manual

Ultrasound power generator

Advertisement

Quick Links

Sound Field Instrumentation
ULTRASOUND
POWER GENERATOR
SF610
100 kHz – 10 MHz, 20 W
User Manual
www.gampt.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SF610 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GAMPT SF610

  • Page 1 Sound Field Instrumentation ULTRASOUND POWER GENERATOR SF610 100 kHz – 10 MHz, 20 W User Manual www.gampt.de...
  • Page 2 GAMPT mbH. GAMPT mbH is not liable for damages occurring as a result of incorrect use, or for repairs and alterations carried out by third parties not authorized by GAMPT mbH.
  • Page 3: Table Of Contents

    Amplifier stage (ULTRASOUND AMPLIFIER) ..............11 Example of use ......................13 Technical Details ......................17 Revisions of the user manual ..................19 Please read through the whole user manual before using the device. Ultrasound Power Generator SF610 · User Manual Version 1.0.1 EN...
  • Page 4: Safety Instructions

    Because power ultrasound is produced with the device and the connected ultrasonic probe, the ultrasonic probe must not be used on people or animals. GAMPT mbH · Hallesche Straße 99F · D-06217 Merseburg · Phone +49 3461/2786910 · www.gampt.de...
  • Page 5: Introduction

    The Ultrasonic Power Generator SF610 combines both components in a compact device in combination with an efficient power supply. In addition, the SF610 has a number of safety features that can be very helpful in protecting the ultrasonic probes from overload.
  • Page 6: Device Description

    PROBE RF OUT output (13) signal output of waveform generator output of ultrasound amplifier (BNC port (14) on/off switch of device for ultrasonic probe) GAMPT mbH · Hallesche Straße 99F · D-06217 Merseburg · Phone +49 3461/2786910 · www.gampt.de...
  • Page 7: Rear View

    Attention! Only replace the fuse with the type stated in the manual. If the wrong type of fuse is used, there is a risk of fire. Ultrasound Power Generator SF610 · User Manual Version 1.0.1 EN...
  • Page 8: Lcd Display

    Line 4: ultrasonic current display and power display I r m s : 0 . 0 2 A 0 . 9 2 W Fig. 5: start screen Version 1.1 GAMPT mbH · Hallesche Straße 99F · D-06217 Merseburg · Phone +49 3461/2786910 · www.gampt.de...
  • Page 9: Operation Of The Sf610

    The signal frequency can be tapped at the TTL output (11) as a square wave signal (0-5 V). At the SIGNAL output (13), the non-amplified generator signal is supplied according to the parameters set. When the SF610 is switched on, the signal generator always wakes up with the same initial setting (see Table 1).
  • Page 10 P o u t : I r m s : 0 . 0 2 A 0 . 9 2 W Fig. 11: frequency (initial state) GAMPT mbH · Hallesche Straße 99F · D-06217 Merseburg · Phone +49 3461/2786910 · www.gampt.de...
  • Page 11 4 3 . 5 V P o u t : I r m s : 0 . 0 2 A 0 . 9 2 W Fig. 17: reduce the value by turning left Ultrasound Power Generator SF610 · User Manual Version 1.0.1 EN...
  • Page 12 Unit Minimum Maximum Step Size Frequency 100 000 10 000 000 Amplitude mVpp 2 000 Pulse repetition frequency 20 000 Burst length µs 65 000 GAMPT mbH · Hallesche Straße 99F · D-06217 Merseburg · Phone +49 3461/2786910 · www.gampt.de...
  • Page 13: Amplifier Stage (Ultrasound Amplifier)

    Current continuous Display of voltage and current values The current values of transmitting voltage and current can be read in lines 3 and 4 of the LCD display (3). Ultrasound Power Generator SF610 · User Manual Version 1.0.1 EN...
  • Page 14 The values of current, voltage and power are displayed flashing if the power exceeds a value of 15 W. GAMPT mbH · Hallesche Straße 99F · D-06217 Merseburg · Phone +49 3461/2786910 · www.gampt.de...
  • Page 15: Example Of Use

    Example of use In the following the procedure for operating the SF610 is described step by step using an example. The task is to operate a 2 MHz probe with sinusoidal 2 MHz bursts at a repetition frequency of 20 kHz and a burst length of 50 µs (100 oscillations per burst).
  • Page 16 P o u t : I r m s : 0 . 0 2 A 0 . 9 2 W Fig. 27: Burst length selected as signal variable GAMPT mbH · Hallesche Straße 99F · D-06217 Merseburg · Phone +49 3461/2786910 · www.gampt.de...
  • Page 17 4 3 . 5 V P o u t : I r m s : 0 . 0 2 A 0 . 9 2 W Fig. 31: Signal amplitude selected as signal variable Ultrasound Power Generator SF610 · User Manual Version 1.0.1 EN...
  • Page 18 Attention! Use the CURRENT and VOLTAGE rotary knobs (1) and (2) to adjust the current and voltage limits according to the connected ultrasonic probe (see also Chapter 4.2). GAMPT mbH · Hallesche Straße 99F · D-06217 Merseburg · Phone +49 3461/2786910 · www.gampt.de...
  • Page 19: Technical Details

    Display: 4-line LCD for the display and setting of the parameter values of the signal generator and of the ultrasound generator and of the output voltage of the LASER unit. Ultrasound Power Generator SF610 · User Manual Version 1.0.1 EN...
  • Page 20 40-80 Vpp, continually adjustable Current Limit: 100-600 mA, continually adjustable mode, frequency, burst length and pulse repetition frequency correspond to the values set at the signal generator GAMPT mbH · Hallesche Straße 99F · D-06217 Merseburg · Phone +49 3461/2786910 · www.gampt.de...
  • Page 21: Revisions Of The User Manual

    Revisions of the user manual Revisions of the user manual Revision Revision date Description 1.0.1 October 27, 2020 First edition Firmware version 1.2 (October 2020) Ultrasound Power Generator SF610 · User Manual Version 1.0.1 EN...