Page 1
Lighting Control Engine 3 (fx)+ UL Information for Use Read the Information for Use and the Safety Instructions IC: CL24100575435, CL24100575535 carefully. Subject to modification without prior notice. Typographical and other errors do not justify any claim for Edition: damages. Modification of the product is prohibited. 19.04.24 [EN_LCE3+UL_Setup_v1p0] This manual is designed for electricians, system administrators, and product users.
Page 2
Lighting Control Engine 3 (fx)+ UL — Information for Use Table of Contents Safety instructions Symbols General safety instructions General device description Delivery content Optional accessories Product specifications Connectors and Interfaces General remarks Transport Unpacking Support Warranty regulations Disposal Installation Mounting Power supply Configuration...
Lighting Control Engine 3 (fx)+ UL — Information for Use | Safety instructions 1 Safety instructions Please read the safety instructions, provided in a separate manual, carefully. Make sure that the environmental, mounting, and installation prerequisites are met. This manual should be kept at a safe place and in reach of the device.
Lighting Control Engine 3 (fx)+ UL — Information for Use | General device description 2 General device description Designed to control large and complex projects, e:cue’s Lighting Control Engine 3+ UL and Lighting Control Engine 3 fx+ UL, in the following combined as LCE3(FX)+ UL is a high-performance server with pre-installed SYMPHOLIGHT and Lighting Application Suite (LAS) software.
Page 5
Lighting Control Engine 3 (fx)+ UL — Information for Use | General device description Product specifications Product Product number Lighting Control Engine 3+ UL CL24100575435 Lighting Control Engine 3 fx+ UL CL24100575535 482 x 177 x 490 mm/ Dimensions 18.98 x 6.97 x 19.29 in (incl. (W x H x D) mounting brackets) 18 kg / 39.68 lb (incl.
Page 6
Lighting Control Engine 3 (fx)+ UL — Information for Use | General device description Key lock for the front cover 2 x USB 3.0 interfaces. If USB devices are connected to the USB ports on the front side, the front flap cannot be closed and locked Use only with a closed and secured housing.
Page 7
Lighting Control Engine 3 (fx)+ UL — Information for Use | General device description — Ensure that the mains power supply socket is grounded and the power cable is in perfect condition with no visible damage. — Do not switch off the server with the power button or by removing the power supply, but use the Windows shutdown function to prevent loss of data.
Lighting Control Engine 3 (fx)+ UL — Information for Use | General remarks 3 General remarks Transport Only transport the device in its original packaging. This protects the device from damage. Unpacking Only unpack the e:cue LCE3(FX)+ UL at its installation location. To protect the device against condensation water, unpack it and wait until all moisture remaining in the device has evaporated.
Lighting Control Engine 3 (fx)+ UL — Information for Use | Installation packing materials and the device is subject to the statutory regulations. 4 Installation The installation of the LCE3(FX)+ UL consists of mounting the device, connections to the peripheral devices and to power supply. Supply the device with power after all cabling is completed.
Page 10
Lighting Control Engine 3 (fx)+ UL — Information for Use | Configuration — Ensure the product is well ventilated and that nothing obstructs the product from taking in air at the front and exhausting air at the rear. — Do not place the product close to heat sources or damp places. —...
Page 11
Lighting Control Engine 3 (fx)+ UL — Information for Use | Configuration LCE3(FX)+ UL Operation Connect a display and input devices (keyboard, mouse) to the Lighting Control Engine 3 (fx)+ UL. Display and input devices are always necessary when accessing any application or settings on the LCE3(FX)+ UL. Connect the power supply and switch on the LCE3(FX)+ UL with the power button.
Page 12
Lighting Control Engine 3 (fx)+ UL — Information for Use | Configuration Network Settings LCE3(FX)+ UL Additionally to the network connection to the Internet, the LCE3(FX)+ UL is equipped with a second network adapter. This enables the integration of the LCE3(FX)+ UL into the network of the lighting installation.
Page 13
Lighting Control Engine 3 (fx)+ UL — Information for Use | Configuration set now. If you have further network devices installed, each of these devices have to be configured separately. See the SYMPHOLIGHT Setup Manual for details. Without a DHCP server, attach only one SYMPL node at a time; otherwise, identical IP addresses will conflict and disturb proper communication.
Lighting Control Engine 3 (fx)+ UL — Information for Use | LCE3FX+ UL video input setup 6 LCE3FX+ UL video input setup Configure the video input with the LAS. 7 Troubleshooting Problem Check Reason Details System does not Main switch on the If the main switch Information for Use power up...
Lighting Control Engine 3 (fx)+ UL — Information for Use | Maintenance 8 Maintenance — Do not try to repair the device. Return it to your Traxon e:cue distributor for replacement or repair. — Before dismounting, appropriate measures must be taken to protect the respective components against damage caused by electrostatic discharge (ESD protection).
Page 16
Lighting Control Engine 3 (fx)+ UL — Information for Use | Dismounting 9 Dismounting Before dismounting, appropriate measures must be taken to protect the respective components against damage caused by electrostatic discharge (ESD protection). Shut down the system and disconnect from main power. Disconnect all attached cables. Dismount the e:cue LCE3(FX)+ UL from the rack.