DECO gas fire 302720 version 3.3 Table of contents Welcome! ..........................3 Important preliminary information for the installer ............4 1. Product description ....................5 2.1 Gas fire ..............................6 2.2 IR remote control [O] .........................6 2.3 AÜE (exhaust gas monitoring device) [P] ..................6 2.4 Installation and commissioning instructions for the installer ............6...
DECO gas fire 302720 version 3.3 Welcome! Thank you very much for choosing a DECO gas fire! You have purchased a product that has been successfully manufactured by us for many years. We manufacture our gas fires exclusively in Germany and measure ourselves against these standards every day “Made in Germany”.
Children are not allowed to play with the device. Cleaning and user maintenance must not be carried out by children without supervision. The DECO gas fire may only be controlled when there is a line of sight! We hereby confirm that our burners...
The following information refers to the standard scope of delivery . Individual variations are possible (e.g. connection lengths, decorative material). Essential components of the DECO gas fire (see appendix 1 for illustration) 2.2.1 Burner bed [A] 2.2.2 Support frame [B] 2.2.3 Pilot guard [C]...
DECO gas fire 302720 version 3.3 3. Technical data Gas connection: ½” internal thread or (f or connection without double nipple) ½” cylindrical external thread, f lat sealing Electrical connection 230 V AC/16 A Triple values natural gas Liquefied gas...
DECO gas fire 302720 version 3.3 4. On-site requirements To install a DECO gas fire, the following requirements must be met: 4.1 Fireplace The fireplace must be made of non-combustible material. All devices for reducing the chimney delivery pressure must be removed or blocked in the open position - unless national regulations to the contrary exist.
- in as equal a proportion as possible in front of and behind the fire line. 4.4 Installation space The DECO gas fire is hung in the installation space provided using the support frame [B] . This installation space is located below the firebox floor of the fireplace. It should be designed in such a way that the burner bed [A] is almost flush with the firebox floor.
We are happy to help. 4.5 Gas connection The DECO gas fire is factory- set to the type of gas ordered ( earth or Liquefied gas ). A gas pipe must be provided to supply the required type of gas. The design must be based on consumption and the on-site conditions.
4.7 Precautions for installing the IR receiver The DECO gas fire is controlled with an IR remote control [O] (item no. 12.259). The receiver (item no. 12.248) for the IR signals is connected to the burner control via cable [J].
DECO gas fire 302720 version 3.3 An appropriate option must be provided for laying the IR cable and installing the IR receiver. The IR cable must not be crushed or touched by hot parts. For example, it must not be carried out under the support frame [B].
DECO gas fire 302720 version 3.3 The IR cable must not be crushed or touched by hot parts. For example, it must not be carried out under the support frame [B]. 5.2 Gas connection Connect the flexible gas hose [G] to the existing gas line on site. Open the gas connection fitting.
DECO gas fire 302720 version 3.3 Never place a piece of wood lengthwise on a vent . This impairs ventilation and can result in the overheating of the control unit. Never place wood directly on the pilot burner. This can affect the ignition. There would also be a risk that an ignition electrode could be bent or broken if the wood was moved carelessly.
DECO gas fire 302720 version 3.3 If you want these devices to be controlled via the gas fire control, we recommend using our AIO (All In One ) - available as an option. Please refer to the AIO installation instructions for their installation.
DECO gas fire 302720 version 3.3 Point the remote control at the IR receiver (a “clear view” is required; maximum range 10 m) • Press buttons 1 and 10 one after the other within 2 seconds . The ignition sequence is initiated.
If the AÜE does not react as described above, it is usually incorrectly positioned. In this case, please correct the position of the AÜE. As already mentioned, DECO gas fires are installed in individually designed fireplaces. Therefore, no absolute statement can be made about the exact position of the AÜE in these instructions.
DECO gas fire 302720 version 3.3 The pilot burner attempts to ignite for 4 x 10 seconds ( ticking noise ) but does not produce a pilot flame . The control switches off for safety reasons and malfunctions. • Check the gas supply (is there gas, is the gas line vented, is the valve open?).
As a rule, it makes sense to involve the electrician carrying out the work. To ensure the DECO gas fire functions properly, please proceed as follows: •...
Disconnect the device from the power (pull the plug) or switch off the fuse 8. Warranty The function of the DECO gas fire is guaranteed for a period of 24 months, a maximum of 27 months after the delivery date, provided it is properly installed and...
Page 21
DECO gas fire 302720 version 3.3 Information/tip Meaning of the LEDs and beeps GKS 17/2 and LME Beeping GKS LED GKS Caused the connection to the Continuous Red steady light Out of Turn the power supply is tone plug 180°...
Page 22
DECO gas fire 302720 version 3.3 Mistake Caused measure After making the electrical The burner is phase sensitive Insert the plug into the socket the connection, the burner beeps other way around. constantly. There is an ignition spark but no no fuel gas;...
DECO gas fire 302720 version 3.3 9. Appendix ESSENTIAL COMPONENTS OF THE FIREPLACE [C] Pilot guard Beneath pilot burner [B] support frame [D] ventilation slots (circumferential) [ A ] Burner bed [G] gas flexible hose (screwable) [H] power cable [J] Infrared receiver...
DECO gas fire 302720 version 3.3 3. INSTALLATION WALL MOUNTED OPERATION AND BUS SYSTEM - CONNECTION Leads: Electrical cables at least 3 x 1.0 mm² (power supply) + 9 x 1.0 mm² NYY or NYM (control) Circuit diagram Please note:...
Page 26
DECO gas fire 302720 version 3.3 connecting cable 1 = +24V 2 = Burner on/off button/flame smaller 3 = Crackle generator button on/off/quieter 4 = Reset button in case of malfunction 5 = Ground 6 = Burner on/off button/flame larger...
Need help?
Do you have a question about the Surface Fire 302720 and is the answer not in the manual?
Questions and answers