DUOVOLT JUMP START BOX
QUICK START GUIDE
Typical installation:
12V
Control
OFF
Switch
24V
Merlin SmartBank
Pro Switch Input 1
Ignition
Feed 12v
Note 4
Note 1
Split Charge
Contactor
Note 1
Fuse
Note 1
12V Vehicle Battery
Caution! Ensure always that the correct polarity is observed on the Jump Start Box wiring. Serious damage to the Jump Start Box will occur if wires are shorted or connected
the wrong way around.
Caution & Warning! Failure to connect an ignition supply to the Jump Start Box may cause engine start battery excessive discharge and serious damage to internal components.
Fuses should be located as close as possible to the battery positive terminal of each battery bank
High current cables must have a current rating higher than that of the associated fuse.
Diagram shows typical split charge device contactor. Merlin recommends use of SmartBank Pro as the device can be inhibited when Jump Start Box is operating in 24V mode.
The DuoVolt Jump Start Box requires a pair of dedicated 12V batteries. Other loads (such as inverters) must not be run from these batteries as it will cause imbalance.
Merlin Equipment Ltd
WH 0.75mm
RD 1.0mm
Fuse
Note 2
Fuse
Note 2
Note 1
Note 1
GND
Jump Start Box
Merlin Jump Start Box
Fuse
Note 2
Note 1
12 / 24V Battery Bank
– Quick Start Guide
350A Anderson
Connector
12 / 24V
Output
Notes:
1. Vehicle battery and 12 / 24 battery bank cabling
not supplied with Jump Start Box.
BK 1.0mm
2. 300A mega fuses to be located between each
battery and main vehicle DC input.
3. Unit must be externally earthed to vehicle
ground / chassis connection.
4. Unit must be externally supplied from vehicle
ignition feed only. Max 10A at 12V DC.
Note 1
Note 3
GND
GND
Revision A

Advertisement

loading
Need help?

Need help?

Do you have a question about the DUOVOLT JumpStart and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Merlin DUOVOLT JumpStart

  • Page 1 High current cables must have a current rating higher than that of the associated fuse. • Diagram shows typical split charge device contactor. Merlin recommends use of SmartBank Pro as the device can be inhibited when Jump Start Box is operating in 24V mode. •...
  • Page 2 The auxiliary battery bank can be split charged from the engine battery bank via a split charge device whilst the engine is running. To do this, the control switch must be in the ‘12V’ position. It will not split charge the auxiliary battery bank if the switch is in the ‘Off’ or ‘24V’ position. Merlin recommends use of SmartBank Pro as a split charge device as this can be inhibited when Jump Start Box is operating in 24V mode.

This manual is also suitable for:

19-7500