Irk hp high power-ip20 electric infrared heater (38 pages)
Summary of Contents for Helios Radiant EHSAFE15ALS
Page 1
PERSONE ( LOCAL WARMING ). PER UTILIZZO DIVERSO CONSULTARE PRIMA LA DIREZIONE TECNICA STAR PROGETTI ITALIA THE HEATER IN MODEL HELIOS RADIANT Cruise HAS BEEN DESIGNED TO HEAT UP AREAS WITH THE PRESENCE OF PEOPLE. ( LOCAL WARMING ). FOR A DIFFERENT USE, YOU SHOULD CONTACT THE TECHNICAL...
Page 2
Prima di usare il prodotto leggere attentamente le istruzioni contenute nel presente libretto. Star Progetti non potrà essere ritenuta responsabile per eventuali danni a persone o cose causati dal mancato rispetto delle indicazioni di seguito elencate, la cui osservanza assicurerà invece la durata e l’affidabilità, elettrica e meccanica, dell’apparecchio.
Page 3
I T A L I A N O ATTENZIONE: QUESTO SIMBOLO INDICA CHE È NECESSARIO PRENDERE PRECAUZIONI PER EVITARE DANNI ALL’ UTILIZZATORE 1. Questi apparecchi non devono essere utilizzati da persone (bambini inclusi) con ridotte capacità fisiche, sensoriali o mentali a meno che non siano controllati o istruiti all’uso degli apparecchi da persone responsabili della loro sicurezza.
Page 4
HELIOS RADIANT Local Warming I T A L I A N O MOD. Cruise 1500 Watt (cod. EH SAFE 15ALS) / 2000 Watt (cod. EH SAFE 20ALS) ISTRUZIONI D’USO ATTENZIONE: La sicurezza dell’apparecchio è garantita solo con l’uso delle seguenti istruzioni, pertanto è...
Page 5
L’USO IMPROPRIO DEI SUDDETTI RISCALDATORI PUO’ CAUSARE GRAVI DANNI A COSE E PERSONE. Tutti i riscaldatori devono essere installati ed utilizzati esclusivamente da personale qualificato. Se il cavo di alimentazione e danneggiato, esso deve essere sostituito dal costruttore in modo da prevedere ogni rischio •L’...
9.POSIZIONAMENTO Regolare il riflettore di Helios Radiant Cruise nella direzione del fascio richiesto con l’installazione a parete. Si tratta normalmente di un’inclinazione di circa 45 gradi rispetto all’orizzonte. Non installare mai Helios Cruise su una superficie infiammabile, né rivolgerlo verso una superficie infiammabile. Helios Radiant Cruise deve essere posto ad una distanza libera (linea visiva) non inferiore a Mt.
Page 7
Manutenzione ordinaria – Ispezioni : Se questo riscaldatore dotato di valvola di sfiato viene utilizzato in ZONE MARINE è doveroso mantenerlo in perfetta efficienza. Questa prescrizione è dovuta alla presenza di sali nelle atmosfere marine che nel tempo si possono depositare con conseguenze sull’efficienza e sicurezza globale dell’apparecchiatura.
Page 8
E N G L I S H HELIOS RADIANT Local ENGLISH Warming Cruise MODEL 1500 Watt (cod. EH SAFE 15 A LS) / 2000 Watt (cod. EH SAFE 20 ALS) OPERATING INSTRUCTIONS PLEASE NOTE: safe use of this equipment can only be ensured if the user complies with these directions.
All heaters must be installed and used only by qualified persons To prevent all risks, if the supply cable is damaged, it must be replaced by the constructor. Appliance is to be installed on non-combustible surfaces ⚫ The devices must be connected to an earth connection system ⚫...
Point the Helios Radiant Cruise reflector beam as required during wall installation. Normally the appliance is tilted at approx. 45° with respect to the horizontal line. Never install Helios Radiant Cruise on a flammable surface or direct it toward a a flammable surface. The appliance must be positioned at a distance (line of sight) of no less than 2.0 m, unencumbered, from objects such...
Ordinary Maintainance – Inspections: If this heater equipped with a pressure valve is used in SEASIDE AREAS, it is right to keep it in perfect efficiency to allow it to work properly. This presciption is because of the presence of salt in the marine areas that with the time can sediment, thus affecting the efficiency and the overall safety of the device.
Page 12
INSTALLAZIONE A PARETE ATTENZIONE - INSTALLARE L'APPARECCHIO SEMPRE IN POSIZIONE ORIZZONTALE COME DA DISEGNO WALL INSTALLATION PLEASE NOTE - THE APPLIANCE MUST ALWAYS BE INSTALLED HORIZONTALLY, AS ILLUSTRATED IN THE DRAWING 32 cm 100 cm 100 cm h = 200 / 350 cm DISTANZE MINIME DI SICUREZZA MINIMUM SAFETY DISTANCES...
POSIZIONAMENTO A SOFFITTO Questo è il posizionamento ideale a soffitto (fig.1) perchè permette di avere un'area riscaldata più ampia ed efficiente. CEILING INSTALLATION This is the ideal ceiling positioning (draw.1) to attain a higher performance of the heater and a wider heated area. 4x M6 32 cm α...
Page 14
Particolare dell’aggancio/snodo posteriore Detail of bracket on the back...
Page 15
CERTIFICATE OF GUARANTEE - THE GUARANTEE EXCLUDE REPLACEMENTS OF THE BULB We congratulate you on the purchase of our patio heaters HELIOS RADIANT CRUISE. Validity 2 years from date of purchase of the appliance: the guarantee expires after this period. The invoice, receipt or hire purchase agreement shall prove the duration of the guarantee period.
Page 16
Local Warming Modello depositato – BREVETTATO Registered model – PATENT PENDING MADE IN ITALY SEDE CENTRALE/PRODUZIONE – HEADQUARTERS/PRODUCTION: STAR PROGETTI Tecnologie Applicate SpA - Via Cassino D’alberi,17 - 20067 TRIBIANO (MI) - ITALY Tel +39/02/90639261 Fax +39/02/90639259 www.starprogetti.com info@starprogetti.com STAR PROGETTI FRANCE Sarl - 345, Rue du Bois Bernoux – 71290 CUISERY - FRANCE Tel +33 3 85 401 262 Fax +33 3 85 400 691 www.starprogetti.com ed.01/2020...
Need help?
Do you have a question about the EHSAFE15ALS and is the answer not in the manual?