VEVOR 1050265 Manual
VEVOR 1050265 Manual

VEVOR 1050265 Manual

Fire pit burner/pan

Advertisement

Technical Support and E-Warranty Certificate
www.vevor.com/support
FIRE PIT BURNER/PAN
MODEL:1050265,1050268
We continue to be committed to provide you tools with competitive price.
"Save Half", "Half Price" or any other similar expressions used by us only represents an
estimate of savings you might benefit from buying certain tools with us compared to the major
top brands and doses not necessarily mean to cover all categories of tools offered by us. You
are kindly reminded to verify carefully when you are placing an order with us if you are
actually saving half in comparison with the top major brands.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1050265 and is the answer not in the manual?

Questions and answers

Summary of Contents for VEVOR 1050265

  • Page 1 Technical Support and E-Warranty Certificate www.vevor.com/support FIRE PIT BURNER/PAN MODEL:1050265,1050268 We continue to be committed to provide you tools with competitive price. "Save Half", "Half Price" or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and doses not necessarily mean to cover all categories of tools offered by us.
  • Page 2 CustomerService@vevor.com This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won't inform you again if there are any technology or software updates on our product.
  • Page 3: Installation Precaution

    INSTALLATION PRECAUTION PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE Warning: For Outdoor Use Only DANGER CARBON MONOXIDE HAZZARD This appliance can produce carbon monoxide which has no odor. Using it in an enclosed space can kill you. Never use this appliance in an enclosed space.
  • Page 4 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. INSTALLATION AND OPERATION SAFETY GUIDELINES CAUTION: It is NOT recommended outdoor fire features be operated when wind exceeds 25 mph Prior to turning appliance on visually inspect fire feature to ensure debris such as leaves or other combustible material has not inside the feature which could bum and emit embers once the fire feature is turned.
  • Page 5: Specifications

    Inspect the fuel supply connection before each use of the appliance. Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply (Natural or L.P. gas line). SPECIFICATIONS Parameter table- Model#1050265 1050268 - 4 -...
  • Page 6 Model# Installation Size 1050265 19" 12" 19" 22" 2 3/4" 1050268 24" 24" 1 16/25" Model#: 1050265 Model#: 1050268 - 5 -...
  • Page 7 PACKAGE INCLUDE FITS MODEL # Q’TY COMPONENTS PICTURE 1050265 1050268 Fire pit burner Fire pit pan Pan cover Remark: “Y” =Yes DIY YOUR FIRE BURNER/PAN This screw cap allows installing the Fire Pit Burner with the gas exit holes facing up or down depending on the fuel type, region, and fire feature the Fire Pit Burner uses.
  • Page 8 Gas Information Fuel - Before making gas connections ensure appliance being installed is compatible with the available gas type. Gas Pressure - Proper Input Pressures are required for optimum appliance performance. Gas line sizing requirements need to be made following NFPA51.
  • Page 9 Gas Connection -Have the gas supply line installed following local building codes, if any. If not, follow ANSI (Z)223.1. Installation should be done by a qualified installer approved and/or licensed as required by the locality. Note: A listed manual gas shutoff device must be installed prior to the location of the appliance Startup - A small amount of air will be in the gas supply lines.
  • Page 10 Typical Configuration for Propane (LP) Gas Fire Pit Installation 1. Seal Tape - Use Seal tape to seal all threaded pipe joints. 2. LP Air Mixer Required - Propane requires additional air mixed with the gas to burn cleanly. Install air mixer with holes facing away from burner. The propane air mixer should be equal or greater in BTU rating than the burner.
  • Page 11 5. Clearances - Maintain a minimum of 36" clearance on all sides and 8' above your burner. Burners that are greater than 150k BTU should not be installed under any structure. 6. Fire Glass Depth-Fire glass should cover the top of the burner at a depth of 1"...
  • Page 12 Cylinders must be fully opened and the pressure controlled by a reducing pressure regulator to operate properly. Checking for Gas Leaks · Check all fittings and connections. · Do not use open flame to check for leaks. · Never use matches or open flame to test for leaks. Use soapy water or a leak detector.
  • Page 13: Common Troubleshooting

    LIGHTING INSTRCUCTIONS PLEASE CHECK THE AIR TIGHTNESS OF THE ALVE BEFORE USE ! 1. STOP! Before lighting this appliance, read the Gas Cylinder, Important Information, and Enclosures sections. 2. BEFORE LIGHTING: Smell all around the appliance area for gas. Be sure to smell next to the floor of the fire-pit because some gas is heavier than air and will settle in the base of the fire-pit.
  • Page 14: Recommended Accessories

    This is typically caused by high gas pressure. Installing a regulator to reduce the pressure to the recommended pressure will fix this Whistling Noise problem. Sizing the proper regulator requires complex calculations based on source/line pressure, line size and length and turns/bends in gas line.
  • Page 16 Technical Support and E-Warranty Certificate www.vevor.com/support...

This manual is also suitable for:

1050268

Table of Contents