Installation Manual b.safe Isolated Amplifier b.safe solated Ampli er solated Ampli er Cat.No.: Cat.No.: R 660-01 / R 660-04 R 660-01 / R 660-04 A product brand of Bohlender A product brand of Bohlender...
Page 2
Content Compatibility, Safety Information, Installation, Functionality Information Installation dimensions Scope of Delivery Taking into Operation Commissioning of typical Applications: ntroduction solated Am li er or use with ini- is la channel with switch ositions solated Amplifier -channel ill level control with b.safe System Waste Caps LC solated Amplifier -channel ill level control with b.safe System Waste Caps Capacitive ntroduction solated Am li er or use with...
Compatibility Installation The b.safe solated Amplifi er is compatible lease have the sensor cables and the with all b.safe devices for fi ll-level control cables leading to the b.safe ini-Display in- (e cept for b.safe Disc Sensor cat. no. stalled by a trained specialist in accordance .
Page 4
Information Mains connection sing the interchangeable plug attachments connection to the following sockets is possible Input/ Output / Output voltage: Input voltage: - AC - DC Buchse / Socket M8x1 Stecker / Plug M8x1 24V / 0,5A...
Page 6
Sco e o eli er The b.safe solated Amplifi er is delivered ready for installation in a plastic housing that protects against accidental contact of live contacts. A power supply with interchangeable adapter plugs for E Australia K and SA apan is included. With the labelling on the front side of the housing each through-screw connection is clearly assigned to the respective channels functions.
Page 7
Setting of operation modes The b sa e solated Am li er has auto- lease make sure that the plug-in power matic sensor and line break detection. supply is disconnected from the grid Once a compatible sensor is plugged in, and thus there is no voltage.
Page 8
solated Am li er -channel (Cat.No.: R 660-04 ) or use with ini- is la channel Sensor IN Connection of: b.safe Waste Cap LC b.safe Waste Cap Capacitive Power IN ower supply Sensor OUT Connection of: b.safe ini-Display Sensor...
Page 9
Switch settings Connection of b.safe Mini-Display 1 channel Switch position must only be changed for b.safe System Waste Caps Capacitive Factory-set/Setting for System Waste Caps LC 1, 2, 3, 4 to I Setting for System Waste Caps Capacitive 1 to II 2, 3, 4 to I Suitable items for solated Ampli er 1 channel b.safe System Waste Caps LC b.safe System Waste Caps LC...
Page 10
nstallation solated Am li er -channel ill level control with b.safe System Waste Caps LC and b.safe Mini-Display 1 channel Switch position at Isolated b.safe solated Ampli er Ampli er does not have to be to be mounted at the changed re uested position CAUTION:...
Page 11
ATTENTION: Test the existing sensor manually by lifting the fl oat by hand to ensure that it works reliably in the completed installation.
Page 12
nstallation solated Am li er -channel ill level control with b.safe System Waste Caps Capacitive and b.safe Mini-Display 1 channel Switch position on Isolated b.safe solated Ampli er to be fastened at the re uested Ampli er must be changed as shown (see page position with suitable moun- ting material...
Page 13
Test each of CAUTION: the e isting sensors ma- nually by touching the ca- pacitive sensor surface to ensure that they function reliably in the completed installation.
Page 14
solated Am li er -channels (Cat.No.: R 660-01 ) or use with ini- is la channels Sensor 2 IN Connection of: b.safe Waste Cap LC right Sensor 1 IN b.safe Waste Cap Capacitive right Connection of: b.safe Waste Cap LC left b.safe Waste Cap Capacitive left Power IN...
Page 15
Switch settings Connection of b.safe Mini-Display 2 channels Switch position must only be changed for b.safe System Waste Caps Capacitive: Factory-set/Setting for System Waste Caps LC 1, 2, 3, 4 to I Settings for System Waste Caps Kapazitiv 1, 3 to II 2, 4 to I Suitable items for solated Ampli er 2 channels b.safe System Waste b.safe System Waste...
Page 16
nstallation solated Am li er -channels ill level control with b.safe System Waste Caps LC and b.safe Mini-Display 2 channels Switch position on Isolated b.safe solated Ampli er to Ampli er does not have to be be fastened at the re uested changed.
Page 17
Test the e isting CAUTION: sensor manually by lifting the fl oat by hand to ensure that it works reliably in the completed installation.
nstallation solated Am li er -channels ill level control with b.safe System Waste Caps Capacitive and b.safe Mini-Display 2 channels Switch position on Isolated b.safe solated Ampli er to Ampli er must be changed as be fastened at the re uested shown (see page position with suitable moun- ting material...
Page 19
CAUTION: Test each of the existing sensors manually by touching the capacitive sensor surface to ensure that they function reliably in the completed installation.
nstallation solated Am li er -channels ill level control with b.safe System Waste Caps LC and b.safe Mini-Display Splitter as well as b.safe Splitter for automatic switchover when the canister is full Switch position on Isolated b.safe solated Ampli er to Install b.safe Splitter Ampli er does not have to be be fastened at the re uested...
CAUTION: Test the e isting sensor manually by lifting Then plug in the power plug the fl oat by hand to ensure and connect the power supply that it works reliably in the unit to the mains completed installation. a. Splitter b.
Page 22
nstallation solated Am li er -channels ill level control with b.safe System Waste Caps Capacitive and b.safe Mini-Display Splitter as well as Splitter for automatic switchover when the canister is full Switch position on Isolated b.safe solated Ampli er to Install b.safe Splitter Ampli er must be changed as be fastened at the re uested...
Page 23
CAUTION: Test each of the existing sensors manually by touching the capacitive Then plug in the power plug sensor surface to ensure and connect the power supply that they function reliably in unit to the mains the completed installation. a. Splitter b.
Page 24
solated Am li er -channels (Cat.No.: R 660-01 ) or use with ini- is la Leak channel and Leak-Sensor Sensor 2 IN Connection of: b.safe Leak-Sensor Sensor 1 IN Connection of: b.safe Waste Cap LC b.safe Waste Cap Capacitive Power IN ower supply Sensor 1 OUT Sensor 2 OUT...
Page 25
Switch settings Connection of b.safe Mini-Display Leak 1 channel and Leak-Sensor Switch position must be changed: Settings for System Waste Caps LC for use with Mini-Display Leak 1 channel and Leak-Sensor 1, 2, 4 to I, 3 to II Suitable items for solated Ampli er 2 channels b.safe System Waste b.safe System Waste b.safe System Waste...
nstallation solated Am li er -channels with Leak-Sensor ill level control with b.safe System Waste Caps LC, b.safe Mini-Display Leak 1 channel and b.safe Leak-Sensor Switch position on Isolated b.safe solated Ampli er to Ampli er must be changed as be fastened at the re uested shown (see page position with suitable moun-...
Page 27
CAUTION: Test the Leak- CAUTION: Test the e isting Sensor manually by touching Then plug in the power plug the capacitive sensor surface sensor manually by lifting and connect the power supply the fl oat by hand to ensure to ensure that it functions unit to the mains reliably in the completed that it works reliably in the...
Page 28
solated Am li er -channel (Cat.No.: R 660-04) solated Am li er -channels (Cat.No.: R 660-01) or use with ini- is la Leak channel and Leak-Sensor Leak-Sensor Sensor IN Connection of: b.safe Leak-Sensor Sensor OUT Connection of: b.safe ini-Display Leak Power IN ower supply Sensor 2 IN...
Page 29
Switch settings Connection of b.safe Mini-Display Leak 2 channel with Leak-Sensor Switch position must be changed: solated Ampli er 1 Settings for use of b.safe Leak-Sensor 1 to II, 2, 3, 4 to I solated Ampli er 2 Factory-set switch for use of Mini-Display Leak 2 channels 1, 2, 4 to I, 3 to II Suitable items for solated Ampli er 2 channels...
Page 30
solated Am li er -channels with Leak-Sensor ill level control with b.safe System Wate Cap LC, b.safe Mini-Display Leak 2 channels and b.safe Leak-Sensor Switch position on Switch position on b.safe solated Ampli er to solated Ampli er solated Ampli er be fastened at the re uested does not have to be changed.
Page 31
CAUTION: Test the Leak- Sensor manually by touching . Then plug in the power plug CAUTION: Test the e isting and connect the power supply sensor manually by lifting the capacitive sensor surface the fl oat by hand to ensure to ensure that it functions unit to the mains reliably in the completed...
solated Am li er -channel (Cat.No.: R 660-04) solated Am li er -channels (Cat.No.: R 660-01) or use with ini- is la Leak channels Leak-Sensor and Splitter Sensor IN Connection of: b.safe Leak-Sensor Sensor OUT Connection of: b.safe ini-Display Leak Power IN ower supply Sensor 2 IN...
Switch settings Connection of b.safe Mini-Display Leak 2 channels with Splitter and Leak-Sensor Switch position must be changed: solated Ampli er 1 Settings for use of b.safe Leak-Sensor 1 to II, 2, 3, 4 to I solated Ampli er 2 Factory-set switch for use of Mini-Display Leak 2 channels 1, 2, 4 to I, 3 to II...
Page 34
solated Am li er -channels with Leak-Sensor and Splitter ill level control with b.safe System Waste Caps LC and b.safe Mini-Display Leak Splitter and b.safe Leak-Sensor as well as Splitter for automatic switchover when the canister is full Switch position on Isolated Switch position on Isolated...
Page 35
. Connect signal cable of the b.safe Splitter with the b.safe Mini-Display Leak. Splitter left with Mini-Display Splitter left Splitter right with Mini-Display Splitter right CAUTION: Test the Leak- .Then plug in the power plug CAUTION: Test the e isting Sensor manually by touching and connect the power supply sensor manually by lifting...
Declaration of Conformity or the following products device Sensor capacitive with plug type designation b.safe Sensor capacitive Cat.No. WR 1325-60-50 Cat.No. WR 1325-60-51 The manufacturer / distributor ohlender mb Waltersberg ermany declares that the products fulfil the provisions of - of EMC Directive 2014/30EU Electromagnetic Compatibility - Low Voltage Directive 2006/95/EG has been complied with according to E in view of its protection targets.
Page 37
Declaration of Conformity or the following products device Alarmbo for illing Level Control type designation b.safe Display Wall Cat.No. R 650-01 / R 652-01 b.safe Display Table Cat.No. R 655-01 / R 657-01 b.safe Display TLC Cat.No. R 690-05 b.safe Mini-Display Leak Cat.No.