C Prox Quantek KPN-2 User Manual

Double relay access control keypad & reader

Advertisement

Unit 11 Callywhite Business Park, Callywhite Lane, Dronfield, S18 2XP 
+44(0)1246 417113
sales@cproxltd.com
www.quantek.co.uk
Double Relay Access Control Keypad & Reader 
KPN‐2 
User Manual 
 
 
 
 
 
 
 
 
Please read the manual carefully before installing this unit 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Quantek KPN-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for C Prox Quantek KPN-2

  • Page 1 Unit 11 Callywhite Business Park, Callywhite Lane, Dronfield, S18 2XP  +44(0)1246 417113 sales@cproxltd.com www.quantek.co.uk Double Relay Access Control Keypad & Reader  KPN‐2  User Manual                  Please read the manual carefully before installing this unit  1   ...
  • Page 2 1. Packing list    Name  Quantity  Remarks      Keypad  1    User manual  1    Screwdriver  1      Wall plugs  2  Used for fixing    Self tapping screws  2  Φ4mm×25 mm, used for fixing    Diode IN4004  1  For relay circuit protection      Please ensure that all the above contents are correct. If any are missing, please notify us immediately.    2. Description  The KPN‐2 is a waterproof dual relay access control unit with integrated keypad and card reader.  It is  suitable for mounting either indoors or outdoors in harsh environments. It is housed in a strong, sturdy  and vandal proof zinc alloy powder coated case.   This unit supports up to 999 users in multiple access configurations (card only, PIN only, or card + PIN).  The built in card reader supports EM 125KHz cards.  Both relays can operate in pulse mode or toggle mode. ...
  • Page 3: Specification

    4. Specification    Operating voltage  12‐28Vac/dc  Idle current consumption  <70mA @ 12Vdc, <40mA @24Vdc  Max current consumption  <130mA @12Vdc, <80mA @24Vdc  User capacity  999  Proximity card reader  EM  Frequency  125KHz  Card reading distance  1‐6 cm  Wiring connections  Relay output (x2), exit button (x2), alarm, door contact  Relay  Two (Common, NO, NC)  Adjustable relay time  1‐300 seconds (5 seconds default), or Toggle mode   Relay maximum load  2 Amp  Environment  Meets IP66  Operating temperature  ‐40 to 60⁰C  Operating humidity  0%RH to 98%RH  Physical  Zinc alloy  Colour  Silver  Dimensions  134 x 55.5 x 21mm  Unit weight  340g    5.
  • Page 4 6. Wiring    Colour  Function  Description    Basic standalone wiring Red  AC/DC  12‐28Vac/dc regulated power input  Black  AC/DC  12‐28Vac/dc regulated power input  Green  NC1  Normally closed relay 1  White  COM1  Common relay 1  Blue  NO1  Normally open relay 1  Yellow  OPEN1  Exit button 1 input (other end connects to GND)  Black & Green  NC2  Normally closed relay 2  Black & White  COM2  Common relay 2  Black & Blue  NO2  Normally open relay 2  Orange  OPEN2  Exit button 2 input (other end connects to GND)  Grey  GND  Ground ...
  • Page 5: Sound & Light Indication

    7. Sound & light indication    Operation  LED indicator  Buzzer  Power supply connection  Blue ON 3 sec  ON 3 sec  Standby  Blue flashing every 2 sec  ‐  Waiting for master code after  Yellow flashing every 0.5 sec. Timeout =  ON 1 x 0.5 sec  pressing *  60 sec  In a programming menu  Yellow ON  ‐  Card read correctly in programming  Green ON 0.5 sec  ON 1 x 0.5 sec  Incorrect step in programming  Red flashes 5 x 0.2 sec  ON 5 x 0.2 sec  Relay 1 activated  Green ON for activation time  ON 1 x 0.5 sec  Relay 2 activated  Blue ON for activation time  ON 1 x 0.5 sec  Relay 1 & 2 activated  Green & blue flashing alternatively 1  ON 1 x 0.5 sec  sec during activation time  Card read and waiting for PIN in Card  Blue flashing every 1 sec. Timeout = 10  ‐  + PIN mode  sec  ...
  • Page 6: For Reference

    9. Full programming    Set a new master code    1. Enter programming mode  *  Master code  #       888888 is default master code 2. Change master code  0  New Master code  #  New Master code  #    The master code is any 4‐8 digits, except 00000000 3. Exit programming mode  *        For reference:    User ID is any number 1‐999, only one user per user ID number.   Relay selection: 1 = relay 1 only, 2 = relay 2 only, 12 = both relays simultaneously.   PIN codes can be 1‐8 digits long, 0 and 00000000 are not allowed.  Recording of User ID’s & card/fob numbers is critical. Ideally, they should be kept digitally. See  last page.  PINs can only be deleted or changed by knowing the User ID number.  Cards/fobs can only be deleted or changed by knowing either the User ID number or card/fob  number.    Add Users      1. Enter programming mode  *  Master code  #       888888 is default master code 2. Add a card user by reading card  11 (User ID)  #  (Relay selection)  #  Read card  #    2. Add a card user by card number ...
  • Page 7: Set Relay Configuration

    Delete users     1. Enter programming mode  *  Master code  #       888888 is default master code 2. Delete user – by card  2  Read card  #    Cards can be deleted continuously without exiting programming mode 2. Delete user – by User ID  2  User ID number  #    2. Delete user – by card number  2  Input card number  #  2. Delete ALL users  2  00000000  #      3. Exit programming mode  *     Set relay configuration    1. Enter programming mode  *  Master code  #       888888 is default master code 2. Pulse mode (factory default)    Relay 1  3  1  1‐300  #    Relay 2  3  2  1‐300  #    The relay time is 1‐300 seconds. (1 equals 50mS). Default is 5 seconds.      2. Latch mode    Relay 1  3  1  0  #    Relay 2  3  2  0  #   ...
  • Page 8 Set buzzer volume level    1. Enter programming mode  *  Master code  #       888888 is default master code 2. Set buzzer volume level  6  1  (0‐5)  #     (Factory default is 3) 0 means the buzzer sound is deactivated      3. Exit programming mode  *     Set door open too long detection  A magnetic contact needs to be connected, wire 2 in series if you want to use this feature on both doors. If the door(s) stay  open too long, the built in and/or external alarm will activate.    1. Enter programming mode  *  Master code  #       888888 is default master code 2. Enable door open detection  7  1  1  #  A  #  B  #  C  #    2. Disable door open detection  7  1  2  #   (Factory default)  Notes:  A = 1‐300 = The preset door open duration in seconds before the alarm triggers    B = 1 = Built‐in buzzer ON while alarming  B = 2 = Built‐in buzzer OFF while alarming    C = 1 = External alarm output enabled while alarming  C = 2 = External alarm output disabled while alarming    3. Exit programming mode  *    ...
  • Page 9: Set Strike-Out Alarm

    Set strike‐out alarm  The strike‐out alarm will engage after 10 consecutive failed PIN/card attempts within 10 minutes.    1. Enter programming mode  *  Master code  #       888888 is default master code 2. Enable strike out alarm  7  3  1  #  A  #  B  #  C  #    2. Disable strike out alarm 7  3  2  #       (Factory default) Notes:  A = 1‐300 = Blocking & alarm time in seconds.    B = 1 = Built‐in buzzer ON while alarming  B = 2 = Built‐in buzzer OFF while alarming    C = 1 = External alarm output enabled while alarming  C = 2 = External alarm output disabled while alarming    3. Exit programming mode  *   Reset the alarm: After expiration of the programmed alarm time.      Set tamper alarm  Keypad will alarm if it is removed from its back plate.    1. Enter programming mode  *  Master code  #       888888 is default master code 2. Enable strike out alarm  7  4  1  #  A  #  B  #  C  #    2. Disable strike out alarm 7  4  2  #      ...
  • Page 10 11.  Issue record  Recording of User ID’s & card/fob numbers is critical. Ideally, they should be kept digitally.  PINs can only be deleted or changed by knowing the User ID number.  Cards/fobs can only be deleted or changed by knowing either the User ID number or card/fob  number.    Site:  Door location:    User ID No  User name  PIN  Card number  Issue date  1  2  3  4  10   ...