Safety Test Solutions 435 Moreland Road Hauppauge, NY 11788, USA Phone: +1 631 231-1700 Safety Test Solutions Fax: +1 631 231-1711 E-Mail: NardaSTS@L-3COM.com www.narda-sts.us Germany Sandwiesenstrasse 7 72793 Pfullingen, Germany Phone: +49 7121-97 32-0 Fax: +49 7121-97 32-790 E-Mail: support.narda-de@L-3com.com www.narda-sts.com Italy Via Leonardo da Vinci, 21/23...
Page 3
nardalert S3 Narda Broadband Monitor User’s Guide WARNING This User’s Guide is a subset of the complete Operating Manual you will find on the NS3-TS CD-ROM. The Nardalert S3 Monitor should only be used after you have read the Operating Manual, understood how it operates and consulted with your company’s safety officer.
Page 4
This User’s Guide is a subset of the complete Operating Manual you will find on the NS3-TS CD-ROM. For additional information about the NS3 and the supplied software, please consult the complete Operating Manual.
Useful information This chapter contains basic information about measuring electromagnetic fields, about using the Nardalert S3, and about the structure of this User’s Guide . 1 .1 Measuring electromagnetic fields 1 .2 About this monitor 1 .3 About this User’s Guide Narda...
1 Useful information Measuring electromagnetic fields In today’s world, many industries utilize equipment that generates electromagnetic fields . Our modern need for communications as well as the efficiency of electromagnetic heating systems and the safety that radar systems provide us are just a sample of the appli- cations that are benefitted by exploitation of the electromagnetic spectrum .
1 .3 About this User’s Guide Applications The NS3 performs measurements for human safety purposes, particularly in workplace environments where high electric or magnetic field strengths are likely . It can also be configured to function as a stand-alone area monitor with or without the Narda NBM-580 multiple-channel metering station .
1 Useful information Structure of warnings All warnings are structured as follows: SignaL WorD type and source of danger Consequences of failure to observe warning ➩ Instructions for preventing danger Symbols and marks used in this document Important Instruction – Indicates an instruction that must be followed to avoid danger .
Preparing the nardalert S3 for use This chapter describes all you need to do before starting to use the Nardalert S3 . 2 .1 Unpacking 2 .2 Battery Installation 2 .3 Instrument overview 2 .4 Connecting the sensor Narda...
2 Preparing the Nardalert S3 for use Unpacking Packaging The packaging is designed to be re-used as long as it has not been damaged. ➩ Keep the original packaging and use it whenever the instrument needs to be shipped or transported. Items included ➩...
2 .2 Instrument overview Transport damage Instrument/accessories damaged during transportation Using damaged instrument/accessories can lead to subsequent damage . ➩ Check the instrument and all accessories for damage when you have unpacked them . ➩ If the instrument is damaged, contact your Narda Service Center . The addresses of Narda Service Centers are listed in Chapter 6 of the Operating Manual included on the CD-ROM and on the internet at www .narda-sts .com .
2 Preparing the Nardalert S3 for use Do not insert battery backwards. You could damage the battery Insert battery with door and/or the system positive (+) side will not charge. towards battery door Instrument overview Top panel Alarm LEDs Up Arrow Power (Increase) On / Off...
2.3 Connecting the sensor Side panels Mini USB port Rechargeable for charging and and replaceable data transfer. battery located Fiber Optic port under door. for data transfer only. Connecting the sensor WARNING If the Sensor is not operating properly, or if the proper sensor is not chosen you could be exposed to high field levels without your knowledge.
2 Preparing the Nardalert S3 for use to pass a functional test at turn-on. If in doubt, cycle unit off and then on again to perform connection test. If the sensor is defective, not installed or failing pre-test, it will cause the system to not proceed to measurement mode.
Getting started This chapter describes how to switch on the Nardalert S3 and verify it is operating properly. Initial display screens Checking monitor functions Screen navigation Additional capabilities of optioned units Narda...
3 Getting started Initial display screens The NS3 is switched on by depressing and holding the On/Off button on the left side of the display. The alarm LEDs will illuminate and the vibrator will activate before the splash screen (Figure 1) is displayed.
3.2 Checking monitor functions ➩ If the calibration is more than 2 years old for the sensor, or 4 years old for the basic unit the calibration screen (Figure 4) will have a red background and one of the buttons needs to be depressed to continue.
3 Getting started If no indication is seen on monitor display, verify that the unit passes its turn-on tests and verify the test source is operating properly. Note: Do not use this function test for verifying calibration. This test is only suitable for checking sensors and their connection to the NS3.
Page 21
3.3 Screen navigation Function Function Function Before Menu Menu Selection Sub-Menu Screen Interface Screen 1. If the arrow icon is pointing to the parameter line and the selection process is not active, start the selection process. 2. If the arrow icon is pointing to the parameter line and the selection Performs the process is active, accept the current...
3 Getting started Additional capabilities of optioned units Your NS3 can be upgraded at any time to a full featured monitor that displays additional information as well as stores exposure data. This upgrade can be accomplished by entering a special code through the NS3-TS software and enabling the upgrade.
Page 23
3.4 Additional capabilities of optioned units Factory Defaults Resets all monitor functions back to Factory Default values. F/O Interface Sets fiber optic interface for communication or remote vibrator operation. Factory default is the communication setting. History Displays maximum, minimum and average readings for the last 6 minutes.
3 Getting started Navigating sub-menu screen example 1. Tap the Button when arrow is pointing at Alarm Indication. NS3 display changes to: 2. Tap the key again to select item to be modified. Item is highlighted to confirm selection. 3. Tap either the arrow to cycle through choices.
Page 25
3.4 Additional capabilities of optioned units 5. Tap the arrow once to get to the “Cancel and Exit” selection. Tap to leave the function without implementing the parameter change. 6. To implement the change and to store it in memory so the next time the unit is powered up it will recall the setting, move the arrow icon to the “Save and Exit”...
Operation overview 4.1 Normal operation 4.2 Nardalert S3 default alarm levels 4.3 Special environmental operations 4.4 Using the Nardalert S3 as an area monitor Narda...
4 Operation overview Normal operation The NS3 should be fully charged and configured for your personal use. The factory provides both a lanyard attachment and a belt clip for your convenience, and a silicon skin to help provide protection for the unit against shock. Once you have verified the proper mounting configuration and have charged the unit you should verify that the alarm levels shown on the second start-up screen meet with your company’s...
4.2 Nardalert S3 default alarm levels The battery icon is always displayed on the unit. When the battery displays a “Red” background there is less than 20% life left and the unit should be charged immediately. If the battery level falls below 10%, audible and LED alarms will be generated without vibration or LCD backlight.
4 Operation overview High ELF environments The normal NS3 (with RF/microwave sensor) was not designed to function in areas where the ELF field strength is greater than 6 kV/m. Higher ELF field levels can cause the NS3 to false alarm. If operation is needed in higher field levels, special sensors can be supplied.
Page 32
Safety Test Solutions 435 Moreland Road Hauppauge, NY 11788, USA Phone: +1 631 231-1700 Safety Test Solutions Fax: +1 631 231-1711 E-Mail: NardaSTS@L-3COM.com www.narda-sts.us Germany Sandwiesenstrasse 7 72793 Pfullingen, Germany Phone: +49 7121-97 32-0 Fax: +49 7121-97 32-790 E-Mail: support.narda-de@L-3com.com www.narda-sts.com Italy Via Leonardo da Vinci, 21/23...