Advertisement

Quick Links

Centrometal d.o.o. - Glavna 12, 40306 Macinec, Croatia, tel: +385 40 372 600, fax: +385 40 372 611
ENG
for installation, use and maintenance
of sustainable and airtight stove
TU-A10-5-2024-ENG
H E A T I N G T E C H N I Q U E
H E A T I N G T E C H N I Q U E
Technical instructions
A10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Centrometal A10

  • Page 1 H E A T I N G T E C H N I Q U E H E A T I N G T E C H N I Q U E Centrometal d.o.o. - Glavna 12, 40306 Macinec, Croatia, tel: +385 40 372 600, fax: +385 40 372 611 Technical instructions...
  • Page 2 Stove Dear Customer, cod. 001108 We thank you for having chosen one of our products, the fruit of technological experience and of continual research for a superior quality product in terms of safety, dependability, and service. In this manual you will fi nd all the information and useful suggestions to use your product with the maximum safety and effi ciency.
  • Page 3 THESE SYMBOLS INDICATE SPECIFIC MESSAGES IN THIS BOOKLET: ATTENTION: This warning sign indicates that the message to which it refers should be carefully read and understood, because failure to comply with what these notices say can cause serious damage to the stove and put the user’s safety at risk. INFORMATION: This symbol is used to highlight information which is important for proper stove operation.
  • Page 4 Instructions for safe and effi cient use • • The device can be used by children that are not less Do not expose to direct the fl ow of hot air plants than 8 years old and people with reduced physical, or animals;...
  • Page 5: Operating Area

    Operating area For proper functioning and a good temperature Installation in studio fl ats, bedrooms distribution, the stove shoul be positioned in a and bathrooms in only permitted for location where it is able to take in the air necessary airtight or closed chamber equipment for combustion of the pellet (about 40 m³/h must be with an adequate canalization for oxidising...
  • Page 6: Flue Connection

    Flue connection REMARKS: • The appliance must be installed by a qualified technician in possession of the technical and professional requirements, under its responsibility, to ensure compliance with the rules of good technique. • You need to keep in mind all laws and national, regional, provincial and municipal laws of the country in which you installed the device •...
  • Page 7 Flue The following instructions have the purpose of giving The minimum distances to comply with from any instructions on installation of a good fl ue, however chimneys or refl ux zones are outlined below. they do not replace in any way the standards in force of which a qualifi ed builder must be aware.
  • Page 8 Chimney 30° ROOF The opening area for smoke evacuation must be at least A = MIN. 1,30 m. double the section of the fl ue and must prevent snow B = DISTANCE > 1,50 m. and animals entering. The measurement of the opening C = DISTANZA <...
  • Page 9 Charge pellet Fuel is loaded from the upper part of the stove by opening Never remove the protection grille a door. in the hopper. When fi lling, do not Pour the pellets in the hopper. This is easier if performed let the sack of pellets touch any hot in two steps: surfaces.
  • Page 10 Stove start up First lighting of the stove • Before switching on, make sure that the grate is clean and empty of any pellet residues from previous combustions. Otherwise make sure you empty and clean it • Fill the container 3/4 full with the pellets recommended by the manufacturer •...
  • Page 11: Control Board

    Control board 12 13 to indicate that the resistance is warming the air which will fire the pellets. 10. On the display you can read the different working functions of the stove, the room temperature and the set working power. In the event of a malfunction, the display shows the relative error codes (see paragraph on alarm codes).
  • Page 12: Information Display

    Information display LoaDPELL LoaD PELL LoaD PELL The stove is off. The stove is in the pre-heating The stove is in the pellet loading phase of the electrical resistance. phase and the electrical resistance The electrical resistance and the is on. The electrical resistance, the fume extractor leds light up on the fume extractor and alternately the display.
  • Page 13 Programming User programming is possible through the menu accessible by pressing MENù. The technical menu will appear as follows: MN01 Current day MN02 Current hour MN03 Current minutes MN04 Access technical parameters MN05 Timer ON 1 Hourly programming Switching on Timer 1 MN06 Timer OFF 1 Hourly programming Switching off Timer 1...
  • Page 14: Remote Control

    12.6 OFF timer 1-2-3 hours minutes off Press MENù key several times to select MN06. Then press keys 1 and 2 to set timer hours and minutes. At the end press button 8 repeatedly until exiting the technical menu or wait 20 seconds. Initial load function (where present - optional) When the tank is completely empty, in order to avoid failure of the next ignition, you can use this function which activates the auger for 30 seconds to allow the tank to be fi lled.After fi lling the tank, press the Menu button on...
  • Page 15: Alarms Signal

    Alarms signal NO ACC If during the ignition phase the fumes temperature does not increase by a set value or does not reach the set temperature in the expected time, the mother shows an ignition error message. • The ignition phase ends and the stove goes to controlled cooling mode. •...
  • Page 16 Stove maintenance and cleaning Before performing any maintenance operation on the stove, take the following precautions: • make sure that all parts of the stove are cold; • make sure that the ashes are completely extinguished; • make sure that the main switch is in the OFF position; •...
  • Page 17 Surface cleaning To clean the surfaces use a rag soaked with water or at most neutral soap and water. The use of aggressive detergents or thinners can damage the surfaces of the stove. Before using any detergent it is advisable to try it on a point that is not in sight or contact the Authorised Service Centre for all advice on the matter.
  • Page 18 RIMUOVERE COPERCHIO E GUARNIZIONE ISPEZIONEFUMI SVITANDO I GALLETTI Remove the cap and clean the T-fitting located behind the stove. Cleaning the exhaust system Until reasonable experience on the operating conditions is gained, this maintenance should be performed at least monthly. RIMONTARE COPERCHIO E GUARNIZIONE ESEGUIRE LA PULIZIA PER CIASCUNO DEI 4 FORI INDICATI IN DALLE FRECCE ROSSE CON L'APPOSITO SCOVOLO, PULIRE I TUBI SI SCAMBIO...
  • Page 19: Maintenance And Cleaning

    Maintenance and cleaning All cleaning of all parts must be carried out with the stove completely cold and unplugged to avoid burns and thermal shock. The stove does not need much maintenance if used with certified quality pellet. The need for maintenance varies depending on the conditions of use (switching on and off repeatedly) and depending on the performance required.
  • Page 20: Safety Devices

    Safety devices Tampering with the safety devices is prohibited. It is only after eliminating the cause which gave rise to the intervention of the safety system, that it is possible to relight the stove and thus reset the automatic operation of the sensor. To understand which anomaly has occurred, consult this manual at paragraph relating to alarms which explains what to do based on the alarm message the stove display.
  • Page 21: Electrical Connection Scheme

    Electrical connection scheme...
  • Page 22: Problems And Solutions

    Problems and solutions All repairs must be carried out exclusively by a specialised technician, with the stove com- pletely cold and the electric plug pulled out. Is prohibited from any unauthorized modifi - cation to the device and the replacement of parts with other non-original. The operations marked in bold type must be carried out by specialised personnel.
  • Page 23 The stove does not 1. The tank is empty. 1. Fill the tank with pellets turn on automatically 2. The resistance does not reach 2. Check the electrical wiring and fuses, replace if the the temperature resistance is broken 3. Resistance damaged 3.
  • Page 24 The stove is clogged 1. Flue with presence of stretches 1. Perform periodic cleaning. See paragraph stove early in the brazier too long or clogged installation in the user manual. Check chimney cleaning with burning 2. Too pellet 2. Decrease in the parameters the charge level of the irregular, door glass 3.
  • Page 25 The fi re goes out 1. The pellet tank is empty 1. Fill the tank with pellets or the stove stops 2. No power 2. Check plug and presence electricity automatically 3. Pellets not being fed 3. Fill the tank with pellets 4.
  • Page 27 M-CORE REV. R01 M-CORE GDO-05 40² 80¹ 1. USCITA FUMI / SMOKE EXHAUST 2. ARIA / AIR AMG S.p.a. Via delle Arti e dei Mestieri, 1/3 - 36030 San Vito di Legu M-CORE GDO-05 REV. R00 1. USCITA FUMI / SMOKE EXHAUST 2. ARIA / AIR AMG S.p.a.
  • Page 28 Company assumes no responsibility for possible inaccuracies in this book originated typographical errors or rewriting, all the pictures and diagrams are principal and it is necessary to adjust each actual situation on the field, in any case the company reserves the right to enter their own products such modifications as considered necessary. Centrometal d.o.o. Glavna 12, 40306 Macinec, Croatia www.centrometal.hr central tel: +385 40 372 600, fax: +385 40 372 611 e-mail: servis@centrometal.hr...