Quick change ultrafiltration drinking water system (24 pages)
Summary of Contents for Aqua Flo CRO-800UX6
Page 1
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. If you are unsure about installing the CRO-800UX6, please contact your dealer. Test the water periodically to verify that the system is performing satisfactorily.
IMPORTANT WARRANTY AND MAINTENANCE INFORMATION Please have the information below filled out and available when calling in for parts or warranty: Model number: Serial number: Date installed: Installed by: CHECK MODEL LABEL AND SERIAL NUMBER Model Information and Serial Number are located on the side of the system as shown.
IMPORTANT WARRANTY AND MAINTENANCE INFORMATION CHECK MODEL LABEL AND SERIAL NUMBER READ THIS PAGE FIRST RO SYSTEM SPECIFICATIONS UNPACK & INSPECT YOUR RO SYSTEM RO SYSTEM DIMENSIONS OVERVIEW OF THE RO SYSTEM’S COMPONENTS INSTALLING RO UNIT START-UP INSTRUCTIONS LED DISPLAY & TOUCH KEYS PROGRAMMING GUIDE SERVICE AND MAINTENANCE TROUBLE SHOOTING GUIDE WARRANTY...
READ THIS PAGE FIRST You must read and understand the contents of this manual This unit must be operated at temperatures between before installing or operating your RO system. 5°C - 38°C (41°F and 110°F) Personal injury or property damage could result if you fail to ...
RO SYSTEM SPECIFICATIONS CRO-800UX6 Model: CRO-800UX6 Water Supply Potable Water Feed Line Pressure 14.5 - 58 psi Flow Rate 0.62 gal/min (2.3 L/min) Salt Rejection* ≥93.6% Recovery* Feed Water Temperature 5~38 °C Ambient Humidity ≤90% Sound Level ≤60dB Input 100~240V AC 50/60Hz...
Impurities are flushed away in the drain stream. The RO membrane featured in the CRO-800UX6 system offers exceptional contaminant rejection, application versatility and long life. The membrane material is sensitive to an attack by chlorine.
INSTALLING RO UNIT Before Installation 1. Check the accessories in the packing box and confirm if they are complete. 2. Shut off the water supply before installation. 3. Prepare the tools that are required for installation. Suggested Installation Tools Recommended Tools For Installation 1.
Tubing Connections Faucet: Connect to RO water faucet Inlet: Connect to Feed Water Power Drain: Connect to Drain Water Faucet Inlet Drain Power: Connect to Power Supply The following steps will enable you to install the system quickly and orderly. Some variation may be necessary depending on the installation.
Step-2 Faucet Installation Dispenser Faucet– The faucet is designed to be mounted on the rear lip of the Faucet sink. It may be installed in an existing sprayer attachment hole or in a hole drilled at the time of installation. It may also be mounted to an adjacent counter top. It should be positioned so that water is dispensed over the sink.
Step-3 Install T-Adapter 1. Turn off the cold water supply, disconnect the hose pipe. Take the T-Adapter out from the accessory bag, install it on the pipe line as shown in figure 2a & 2b. 2. Take out the 3/8" tubing from the accessory bag, cut it to proper length, attach T-Adapter one end to the T-Adapter, attach the other end to the Inlet water connection on RO module assembly, make sure the tubings are fully seated.
START-UP INSTRUCTIONS Step-6 Start-Up Instructions CAUTION! 1. Check system to verify all components are correctly installed. Do not drink water produced by the system 2. Open inlet valve, connected to water supply. until the Start-Up 3. Plug in power cord, connect power on. procedure has been followed completely! 4.
Page 15
Filter Element Reset program. Leak Alert The CRO-800UX6 comes with a leak detector mounted on the bottom of the system that provides an audible and visual alarm if it detects any water on the surface below. The systems solenoid valves and pump will shut off preventing further leaking.
The service schedule above is only for reference. NOTE CRO-800UX6 is designed only for household use, do not install the system where the water usage demand is high. Filter Element Should Be Replaced If Following Situations Occur: 1.
SERVICE AND MAINTENANCE (CONTINUED) How to Replace Filter Elements: 1. Close the Inlet valve to shut off water supply. 2. Open the faucet to release pressure. 3. Turn off power supply. 4. Rotate the old filter element 90° counter-clockwise, so the triangle icon on top of filter element is pointed at icon, take out the old element See Figure 6.
TROUBLE SHOOTING GUIDE Problem Problem Possible Solutions Possible Solutions 1. Pump Not Running, No Product Water A. Power supply is not on. A. Plug in the power supply or wait for power to restore. B. Transformer is damaged. B. Replace the transformer C.
Aqua Flo® Reverse Osmosis Limited 2 Year Warranty Subject to the conditions and limitations described below, Canature WaterGroup™ warrants its AquaFlo® Reverse Osmosis Drinking Water Treatment Systems (excluding membrane and cartridge filters), when installed in accordance with Canature WaterGroup™ specifications, to be free from defects in materials and workmanship under normal use within the operating specifications for a period of two (2) years from the date of purchase (with bill of sale).