Download Print this page

Advertisement

Quick Links

Fireray One Lite
User guide
Protecting lives. Protecting assets. Protecting property.
ffeuk.com | ffeus.com
0044-143-01

Advertisement

loading
Need help?

Need help?

Do you have a question about the One Lite and is the answer not in the manual?

Questions and answers

Summary of Contents for Fireray One Lite

  • Page 1 Fireray One Lite User guide Protecting lives. Protecting assets. Protecting property. ffeuk.com | ffeus.com 0044-143-01...
  • Page 2 In the box FIRERAY ONE LITE FIRERAY ONE LITE DETECTOR HEAD BASE REFLECTOR SHORT RANGE MASK ffeuk.com ffeus.com...
  • Page 3: General Information

    General information 0.5 m (20") Do NOT position Detector where personnel or objects can enter the beam path. Do NOT install the Detector or Reflector in environments where condensation or icing are likely to occur unless preventative measures have been taken. ≥...
  • Page 4 Wiring The Fireray One Lite contains software Supply + that processes the output of the Supply - Detector and generates a Fire and Fault Ext Reset status. This status is output using volt- free relays so that it can be interfaced to all types of conventional Fire Control Panel (FCP).
  • Page 5 Mounting Mount Base Mark and drill holes for mounting of Plug the cable from the Detector Base. Using appropriate hardware head into the connector on the PCB (not supplied) mount Base securely in the Base. in orientation shown. Ensure Base is mounted on solid surface such as a structural wall or girder.
  • Page 6 AND SETTINGS INDICATOR ALIGNMENT STATUS SLIDE INDICATORS SWITCH The door should remain attached to the Fireray One Lite, however on the rare occasion that it becomes unattached, it is possible to reattach Align Operate the tether by reinserting the barbed end.
  • Page 7 Detector is being When set to high-power alignment, reflected by some other object in or the Fireray One Lite will align in seven around the beam path. Take care minutes. Setting the Low Power to make sure there are no reflective Alignment switch to OFF (the right- objects within 0.5 m of the centre of the...
  • Page 8 Alignment Stage 2 (Alignment) moves the If alignment fails, ensure that the correct infra-red beam exactly to the middle number of Reflectors are installed, of the Reflector. that the correct clearance has been given and that there are no reflective To select automatic alignment, ensure surfaces around the Reflector or close the alignment setting switch is set to the...
  • Page 9 Settings Fire threshold Threshold EN54-12:2015 and AS7240.12:2018 Threshold Selection: Only the 25% and 35% thresholds are approved. Both are suitable for separations of 5 m to 100m (164 - 328 ft) . UL 268 Threshold Selection: Select the correct threshold for the installed distance: Separation Acceptable between Detector...
  • Page 10 Status indications and troubleshooting Status indications Testing During normal operation the Detector After installation or cleaning it is status indicator LED will flash green recommended that a Fire test is every 10 seconds, and both Fire and performed. Fault relays will be in their normal position.
  • Page 11: Technical Information

    Fire & fault Rrelays (VFCO, Resistive) – contact voltage Fire & fault relays (VFCO, Resistive) – contact current Cable gauge inch Housing flammability rating UL940 V0 Fireray One Lite dimensions and weights Height Width Depth Weight Reflective Detector, including Detector base 181 mm 130 mm 134mm 0.7 kg...
  • Page 12 India Sales Office Head Office HQ US Sales and Distribution Bangalore FFE Limited FFE Limited India 9 Hunting Gate 1455 Jamike Ave Ste 200 e: india@ffeuk.com Hitchin, Hertfordshire Erlanger w: www.ffeuk.com SG4 0TJ KY 41018-3147 England t: +44 (0) 1462 444 740 t: +1 859 957 1570 e: sales@ffeuk.com e: america@ffeus.com...