  • Page 1 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means - electronic, mechanical, photocopying, recording, or otherwise - without prior written permission of Safety-Kleen Systems,...
  • Page 2: Office Address

    LOCAL SAFETY-KLEEN BRANCH OFFICE ADDRESS PHONE NUMBER...
  • Page 3: Table Of Contents

    ABLE OF ONTENTS Safety Measures ..............................2 The Safety-Kleen Model 1055 Automatic Paint Gun and Equipment Cleaner ............3 Components ..............................3 Specifications ..............................6 Installation ................................ 6 NFPA Hazardous Location Placement Standard ....................7 Assembly ................................7 Paint Spray Gun Placement ..........................10 Operation………………………………………………………………………………………………………………………………………………………..12...
  • Page 4: Safety Measures

    AFETY LEEN YSTEMS M1055 A UTOMATIC AINT PRAY UN AND QUIPMENT LEANER PERATOR OOKLET AFETY EASURES Safety in the workplace is dependent upon the proper use of the M1055 and the cleaning fluid used in it. It is important to carefully follow all safety instructions provided in this booklet, the cleaning fluid’s Safety Data Sheet (SDS) and on the M1055 labels.
  • Page 5: The Safety-Kleen Model 1055 Automatic Paint Gun And Equipment Cleaner

    15. Grounding Cable: Integrated with the unit, one end attaches to the stud on the rear of the 1055, the other end attaches to clean, non-corroded, unpainted metal earth ground source chosen by the...
  • Page 6 AFETY LEEN YSTEMS M1055 A UTOMATIC AINT PRAY UN AND QUIPMENT LEANER PERATOR OOKLET 16. Left Foot Pedal: Activates the flow of virgin cleaning fluid from the left nozzle for the paint gun’s manual cleaning. Use this pedal sparingly; it draws from only ½ of the cleaning fluid container. When the fluid flow diminishes, service will be required.
  • Page 7 AFETY LEEN YSTEMS M1055 A UTOMATIC AINT PRAY UN AND QUIPMENT LEANER PERATOR OOKLET 8, 19 8, 20...
  • Page 8: Specifications

    AFETY LEEN YSTEMS M1055 A UTOMATIC AINT PRAY UN AND QUIPMENT LEANER PERATOR OOKLET PECIFICATIONS Floor Space Width 27 ½ inches (70.0 cm) Depth 27 ½ inches (70.0 cm) Height 60 ¾ inches (154.5 cm) Distance to vent: Maximum of 24 feet The exhaust piping from the M1055 must be vented directly outdoors or connected to a suitable ventilation system in the paint booth.
  • Page 9: Nfpa Hazardous Location Placement Standard

    AFETY LEEN YSTEMS M1055 A UTOMATIC AINT PRAY UN AND QUIPMENT LEANER PERATOR OOKLET NFPA H AZARDOUS OCATION LACEMENT TANDARD The National Fire Protection Agency’s (NFPA) Standard 33, The Standard for Spray Application Using Flammable or Combustible Materials, uses the Class/Division system to designate work areas subject to flammable vapors as hazardous locations, with specific machinery placement and venting specifications.
  • Page 10 AFETY LEEN YSTEMS M1055 A UTOMATIC AINT PRAY UN AND QUIPMENT LEANER PERATOR OOKLET D. C M1055 T ONNECT OMPRESSED OURCE Important! Make sure the ball valve is closed before attaching the compressed air source. Slowly open the ball valve after connection. Doing otherwise may damage the unit, requiring a service call. 1.
  • Page 11: Install The Ductwork

    LUID ONTAINERS 1. Insert a 5 gallon cleaning fluid container, only ½ full of Safety-Kleen cleaning fluid, into a containment pail, and place that assembly on the M1055’s left side. 2. Remove both bungs using a non-sparking wrench and screw flame arrestors into both bungs until secure.
  • Page 12: Paint Spray Gun Placement

    AFETY LEEN YSTEMS M1055 A UTOMATIC AINT PRAY UN AND QUIPMENT LEANER PERATOR OOKLET AINT PRAY LACEMEN Siphon Feed Gravity Feed Gravity Feed Bottom Mounted Paint Cup Top Mounted Paint Cup Side/Swivel Mounted Paint Cup • The method of connecting the spray gun to the M1055, and its position in the cleaning cradle, differs slightly depending on the type of paint spray gun to be cleaned.
  • Page 13 AFETY LEEN YSTEMS M1055 A UTOMATIC AINT PRAY UN AND QUIPMENT LEANER PERATOR OOKLET gravity feed side/swivel mounted paint cup Gravity Feed Paint Spray Gun Placement A. Gravity feed paint spray guns require an extension tube for connecting with the rear nozzle.
  • Page 14: Operation

    3. Drain as much paint as possible from the paint cup into a properly labeled waste paint container. Important! Do not discard paint cup waste or any other materials into the M1055. Doing so will clog the lines, requiring a Safety-Kleen service call.
  • Page 15 AFETY LEEN YSTEMS M1055 A UTOMATIC AINT PRAY UN AND QUIPMENT LEANER PERATOR OOKLET 4. Depress the paint gun trigger and install the trigger clip to hold the paint gun open for cleaning. 5. Fit the black purge air line with a tapered plug. a) Depending on what mode of air-connection the paint gun uses, different tapered plugs that fit all modes are provided in the M1055’s accessory bag.
  • Page 16 Once the flow from the left foot pedal diminishes, Safety-Kleen service will be required. 13. Compressed air can be used to blow out any residual solvent/cleaning fluid from the paint gun.
  • Page 17: Troubleshooting

     be your primary contact with Safety-Kleen.  put the name and phone number of the nearest Safety-Kleen branch on the equipment and/or on the inside cover of this booklet.  provide information about your contract with Safety-Kleen and about the Safety-Kleen service.
  • Page 18: Canadian Hazardous Location Designation

    AFETY LEEN YSTEMS M1055 A UTOMATIC AINT PRAY UN AND QUIPMENT LEANER PERATOR OOKLET PPENDIX M1055 U NITED TATES AZARDOUS OCATION ESIGNATION Electrical Area Classification for Class I Liquid Operations Around Open Containers, Spray Gun Cleaners and Solvent Distillation M1055s source: NFPA 33 ...