Do you have a question about the Smart Care BM 56 and is the answer not in the manual?
Questions and answers
Summary of Contents for Nomo Smart Care BM 56
Page 1
Tensiómetro de brazo ESPAÑOL Manual de instrucciones... Need assistance? Distributed by Please visit www.nomosmartcare.com, contact Nomo Smart Care customer support at Nomo International, Inc. 1 844 888-8854, or email us at customerservice@nomosmartcare.com. 7151 Metro Blvd Edina MN 55439 Need assistance? www.nomosmartcare.com...
Page 2
The Nomo Smart Care Upper Arm Blood Pressure Monitor is fully functional ONLY when (1) set up properly and (2) connected to an active Nomo Hub in the home. READ THIS MANUAL COMPLETELY AND CAREFULLY BEFORE USING THIS PRODUCT Keep this manual in a safe location for future reference LEA TODO ESTE MANUAL CON ATENCIÓN ANTES...
ENGLISH Contents 1. IMPORTANT SAFETY NOTES ..........3 8. Displaying and Deleting Measurements ......12 2. Intended Use ............... 7 9. Care and Maintenance ............13 3. Package Contents ............... 7 10. Troubleshooting Guide ............ 13 4. Device Description .............. 7 11.
Page 4
• Observe the instructions pressure for pregnant women and for users with irregular Read the instructions before starting work and/ heartbeat, diabetes, poor circulation of blood, kidney or operating devices or machines Direct current • The pulse display is not suitable for checking the frequency The device is suitable for use with direct current of heart pacemakers or defibrillators.
Page 5
- Protect the device from impacts, humidity, dirt, marked arm. temperature fluctuations and direct sunlight. - Do not drop the device. - Do not use the device in the vicinity of strong CAUTION electromagnetic fields and keep it away from radio systems •...
• Avoid any mechanical restriction, compression or bending of • Remove discharged batteries from the product and dispose/ recycle in compliance with all applicable laws. • To conserve the batteries, the blood pressure monitor switches • Keep batteries away from children and pets. Batteries may be harmful if swallowed.
2. INTENDED USE 2. Air Tube This blood pressure monitor performs non-invasive measurement 3. Air Tube Connector 4. Air Tube Port and monitoring of arterial blood pressure and heart rate on adult 5. LCD Display 6. USC Port patients. 7. Memory button 8.
5. Tap “BM 56” to add the device to the app. The blood pressure for about 3 seconds. measurements will be uploaded to the “Nomo Smart Care” app. • Press the memory button to toggle between mmHg and kPa. • Press the START/STOP button...
6. MEASURING BLOOD PRESSURE The blood pressure monitor is suitable for home use and needs please consult your doctor to determine which arm should be to be at room temperature when measuring. Measurements can used for the measurement. be performed on either arm. correct arm.
STOP button. Manual transfer of measurement data 2. Press the START/STOP button again to start a measurement. If measurements are taken while away from the Nomo hub or 3. T without a Bluetooth® connection, those measurements cannot be maximum pressure, after which the pressure slowly transferred later.
1. Press the memory button. Repeat the measurement if the irregular heartbeat indicator displays after a measurement. Rest for at least five minutes 2. The Bluetooth indicator starts to flash on the display, ® between measurements and do not talk or move during indicating that the blood pressure monitor is searching for measurement.
8. DISPLAYING AND DELETING Risk Classification Table MEASUREMENTS Hypertension Systolic Diastolic LED Risk (in mmHg) (in mmHg) Category Indicator User Memory Grade 3: Severe Every successful measurement is stored along with its date and ≥ 180 ≥ 110 hypertension time. If there are more than 199 measurements in a particular Grade 2: Moderate user memory bank, the oldest measurement is deleted.
9. CARE AND MAINTENANCE Error Possible cause Solution message • An unknown error Please wait one minute and • Do not use detergents or solvents. occured during repeat the measurement. • Never immerse the device in water or other liquids. measurement Ensure that you do not •...
Oscillometric, non-invasive blood pressure Smart Blood Pressure Monitor BM 56 Method measurement on the upper arm Measurement Measuring range 0-295 mmHg Nomo International, Inc. Range Systolic 57 - 255 mmHg 7151 Metro Blvd Diastolic 25 - 195 mmHg Edina MN 55439...
(ii) repair the Product and pay the labor installation. If this equipment does cause harmful interference to charges of such Nomo authorized service provider for same, at no radio or television reception, which can be determined by turning...
Page 16
Nomo's sole discretion, are the exclusive tornado, earthquake or fire, or due to damage caused by remedies of the customer. Nomo shall not be liable for any automobile accidents or extraordinary impact events, such as incidental or consequential damages caused by the use, misuse dropping or crushing;...
Page 17
PLEASE DIRECT ALL CORRESPONDENCE TO: Nomo International, Inc. Customer Service customerservice@nomosmartcare.com 844.888.8854 www.nomosmartcare.com...
EMC Guidance Warning: Portable RF communications equipment (including The ME EQUIPMENT or ME SYSTEM is suitable for home peripherals such as antenna cables and external antennas) healthcare environments should be used no closer than 30 cm (12 inches) to any part of the equipment , including cables specifed by the manufacturer.
Page 19
Table 2 Guidance and manufacturer’s declaration - electromagnetic Immunity Immunity Test IEC 60601-1-2 Compliance level Test level Electrostatic ±8 kV contact ±8 kV contact discharge (ESD) ±2 kV, ±4 kV, ±8 kV, ±2 kV, ±4 kV, ±8 kV, IEC 61000-4-2 ±15 kV air ±15 kV air Electrical fast...
Page 20
Table 3 Guidance and manufacturer’s declaration - electromagnetic Immunity Test fre- Maximum Distance Test Compliance Band quency Service Modulation Power Level level (MHz) (MHz) (V/m) (V/m) Pulse 380-390 TETRA 400 modulation Radiated RF 18 Hz IEC61000-4-3 GMRS 460, FM ± 5 kHz deviation (Test specifications 430-470 FRS 460...
Page 24
The Bluetooth ® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Beurer North America LP is under license. Other trademarks and trade names are those of their respective owners. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S.