FAS FNI ECT-500-105-S User Manual

Ip 67 io-link master module

Advertisement

Quick Links

USE INSTRUCTIONS
Ordering code:006AA1
Part number:FNI ECT-500-105-S
[ Technical support ]
1 / 25

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FNI ECT-500-105-S and is the answer not in the manual?

Questions and answers

Summary of Contents for FAS FNI ECT-500-105-S

  • Page 1 USE INSTRUCTIONS Ordering code:006AA1 Part number:FNI ECT-500-105-S [ Technical support ] 1 / 25...
  • Page 2 FNI ECT - 500 - 105 - S 4xIO - Link ClassA, 4 DI PNP IP 67 IO-Link Master module user manual 2 / 25...
  • Page 3: Table Of Contents

    Contents Security ..........................4 ■ Expected use ......................4 ■ Installation and start-up ....................4 ■ Corrosion resistance ....................4 ■ Dangerous voltage ..................... 4 ■ General security ........................5 ......................6 Getting started guide 1.1 Module overview ......................6 1.2 Mechanical connection ....................7 1.3 Electrical connections .....................
  • Page 4: Security

    Security ■Expected use This manual describes as decentralized input and output modules for connecting to an industrial network. --------------------------------------------------------------------------------------------------------------------------------- ■Installation and start-up Precautions! Installation and start-up may only be performed by trained personnel. A qualified individual is one who is familiar with the installation and operation of the product and has the necessary qualifications to perform such operations.
  • Page 5: General Security

    General security ■ Debugging Expected use Fault Owner/operator obligations inspection If the defect or equipment failure cannot be corrected, the operation This equipment is Before of the an EMC Class A debugging, equipment compliant read the user must be product. This manual stopped to device produces...
  • Page 6: Getting Started Guide

    Getting Started Guide Module overview 1.Power input port 8 Network input port 2.Module indicator light 9 Ground connection 3.Port 0 10 power output port 4.Port 1 11 Port identification board 12 Network output status 5.Port 2 indicator light 6.Port 3 13 Network output port 7.
  • Page 7: Mechanical Connection

    1.2 Mechanical connection The modules are connected using 2 M4 bolts and 2 washers. Isolation pads are available as accessories. 1.3 Electrical connection 1.3.1 Power interface(L code) Function Description +24V(Brown) +24V(White) Ua+* 0V(Blue) 0V(Black) Ua * Note: If possible, provide sensor/module power supply and actuator power supply separately.
  • Page 8: Network Interface (M8)

    1.3.2 Network interface( M8) Function Send data+ Receive data+ Send data Receive data Note: Unused I/O port sockets must be covered with end caps to meet IP67 protection, etc. 1.3.3 I/O interface (A - code) Function 1(Brown) 24V Maximum current 1A 2(White)...
  • Page 9: Master Module Wiring Method

    1.3.4 Master module wiring method Independent power supply System power Auxiliary power In independent power supply mode, the maximum current of each master station can reach String power supply System power Auxiliary power In the serial power supply wiring mode, if the rear module needs to be connected to the front module, the cumulative current must not exceed 4A.
  • Page 10: Technical Data

    2 Technical data 2.1 Size 2.2 Mechanical data Shell material Die-cast aluminum housing, pearl nickel plated IP67(Only in plug-in or plug type) The shell grade complies withIEC 60529 Power interface M8(male and female) Input port/output port M8 ,A Code(4*female) Size(W*H*D) 32mm*145mm*26mm Installation type 2 Through hole mounting...
  • Page 11: Electrical Data

    2.4. Electrical data Supply Voltage 18~30V DC,conform to EN61131-2 Voltage fluctuation <1% Module operating current at 24V supply voltage <130mA 2.5 Network Port Port 2 x 10Base-/100Base-Tx Port connection Shielded Twisted Pair, Minimum STP CAT 5/STP conform toIEEE 802.3 of cable type CAT 5e Data transmission rate 10/100 M bit/s...
  • Page 12 I/O port state State Function The status of Pin4 input is 0 Closure The status of Pin4 input is 1 Yellow pin4 shortcircuit Flashing red pin1 shortcircuit The status of Pin2 input is 0 Closure The status of Pin2 input is 1 Yellow UA power supply disconnected or network down or pin2 short-circuited Flashing red pin1 shortcircuit...
  • Page 13: Integrated

    Show ESI library---Click on “Install files” in the popup window---Select the corresponding product ESI file. To create a module: Click on the toolbox on the right side----find FAS Fieldbus Modules--- select the product model FNI ECT-502-105-S and double-click on the corresponding product to add it to the master device.
  • Page 14 Module slot data (IOLINK mode): right-click on the module --- select Edit Module Configuration --- drag the required data into the module slot --- if the slave has an output signal, you need to open the master's PIN2 --- click on the I/O mapping --- give the Digital Output Mapping_Output Pin 2 a variable ---- is useful in the program! Output Pin 2 of the output signal port is set to 1 --- that means the configuration is successful! 模块I/o 变量( Module I/o Variables).
  • Page 15 Block slot data (normal IO mode): Right-click on the module---select Edit Module Configuration---drag Digital_IN into the module slot. As shown above, Pro0~4 PIN4 are input settings ---- Configuration completed! 15 / 25...
  • Page 16: Beckhofft Wincatxae Integrated

    3.1.2 Integration in BECKHOFFT WinCATXAE Hereyou will findan exampleofhowtointegrate thismodule intoTwinCATXAE,usingthe CX5050PLC as anexample: Add PLC Path : Right-click on the TwinCAT icon in the lower right corner to open Edit Routes. Click Add...; Add Route Dialog Broadcast Search-Select PLC(CX-3D0A4)-Add Route 16 / 25...
  • Page 17 Enter the default password “1”-click OK to finish adding the PLC path. Add device configuration file: FAS FNI-ECT-502-105 (provided by FAS) Finish adding the configuration file by copying the file to the following path: C:\TwinCAT\3.1\Config\IO\EtherCAT New Project: Open TwinCAT XAE software - - File - New - Project - - Select TwinCAT XAE Project - Enter name -...
  • Page 18 Select Target System: SYSTEM-Choose Target System-Select PLC(CX-3DB0A4)-OK Add module: Pull down IO Options-DEVICES-SCAN; search for master, select Device 2(EtherCAT)-OKAdd module. Pull down IO Options-DEVICES-SCAN; search for master, select Device 2(EtherCAT)-OK 18 / 25...
  • Page 19 Module slot data (IOLINK mode): Under Explorer, find the module FNI-ECT-502-105-S and select Slots to configure the desired slot data. Module Slot PIN2 Data Setting: If there is an output signal from the hub module, PIN2 of the master module must be turned on, and it is given a value in the program ----- to complete the configuration! When the variable Output PIN2 is set to 1 and PIN2 enable is set to 0, PIN2 is closed! 19 / 25...
  • Page 20 Module hub Data Setup (COE Setup): Under Explorer, find the module FNI-ECT-502-105-S and click COE-On-line. 0 Port data settings 8100:0 :Master Pro 1 Port data settings 8110:0 :Master Pro 2Port data settings 8120:0 :Master Pro 8130:0 :Master Pro 3 Port data settings 20 / 25...
  • Page 21 Note that the Index and subindex inputs are in decimal, and the Data input and output are in hexadecimal; (2) FAs Hub common indexing functions: Example: a. Input/Output Configuration: Index =65 , subindex=0; The following figure shows an example of hub configuration:...
  • Page 22: Inovance Am600-Cpu1608Tp/Tn Integrated

    3.1.3 Integration in Huichuan AM600-CPU1608TP/TN Here you will see an example of how to integrate this module into Inproshop, using the AM600-CPU1608TP/TN PLC as an example: Adding a new project : Select the corresponding PLC model for a new project Add module: Double-click Network Configuration ---- Click Import ECT File ---- Select Master Description File FNI-ECT-502-105-S...
  • Page 23 Module slot data: Double-click on the left device box module FNI-ECT-502-105-S ------ Slot Configuration -- ---- to select the desired slot data for configuration Module Slot PIN2 Data Setting: If there is an output signal from the hub module, the master module PIN2 must be turned on and assigned a value in the program ------ configuration is complete! 23 / 25...
  • Page 24: Appendix

    4.Appendix 4.1 Order code Product Ordering Code Ordering code FNI ECT-500-105-S 006AA1 24 / 25...
  • Page 25 25 / 25...

This manual is also suitable for:

006aa1

Table of Contents