Cognex DM500X Quick Reference Manual
Cognex DM500X Quick Reference Manual

Cognex DM500X Quick Reference Manual

Id reader

Advertisement

Quick Links

Cognex DM500X
ID Reader
A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
• C r i t i c a l a n d e x p e d i t e d s e r v i c e s
• I n s t o c k / R e a d y - t o - s h i p
Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate, representative, or authorized distributor for any manufacturer listed herein.
$
3450
.00
In Stock
Qty Available: 1
Used and in Excellent Condition
Open Web Page
https://www.artisantg.com/92168-1
• We b u y y o u r e x c e s s , u n d e r u t i l i z e d , a n d i d l e e q u i p me n t
• F u l l - s e r v i c e , i n d e p e n d e n t r e p a i r c e n t e r

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DM500X and is the answer not in the manual?

Questions and answers

Summary of Contents for Cognex DM500X

  • Page 1 Cognex DM500X ID Reader 3450 In Stock Qty Available: 1 Used and in Excellent Condition Open Web Page https://www.artisantg.com/92168-1 A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
  • Page 2 COGNEX ® DataMan ® Quick Reference Guide san Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan...
  • Page 3: Setting Up Your Dataman

    Getting Started Section Title Page 4 Page 2 • About DataMan 500 • For More Information • DataMan 500 Systems • DataMan 500 Accessories Setting Up Your DataMan Page 8 Reader Layout • Dimensions • Installing the Lens • Mounting the Reader • Connecting the Reader • Reading Distances and Field of View •...
  • Page 4 DataMan software release. Cognex->DataMan Setup Tool v x.x->Documentation->DataMan v x.y.z->Release Notes 4 DataMan 500 Quick Reference Guide DataMan 500 Quick Reference Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 5 DataMan 500 Systems DataMan 500 Accessories CD-ROM Quick Reference High-Speed Omni- 1DMax™ — IDQuick™ — (Setup Tool and Drivers) Guide Part Moving directional Best-In-Class High-Speed (206-6400-400) Applications Code Reading 1D Reading 2D Reading (590-7123) I/O Cable M12 DataMan 500QL I/O Cable M12 to √...
  • Page 6: Reader Layout

    Reader Layout Pushbutton • Push to read • Push and hold 3 seconds to train User LEDs • Use Setup Tool to program RS-232 additional button functions • Green (pulse): Read Status LED • Red (pulse): No read • Red/Green (long pulse): Train or Optimize Focus result Ethernet...
  • Page 7: Installing The Lens

    Dimensions Installing the Lens Observe the following DataMan 500 dimensions when installing your DataMan 500 ships with no lens installed. You must install either a reader. The upper left image shows the illumination accessory. variable-focus liquid lens module or a standard CS-mount lens before using your reader.
  • Page 8 Installing the Lens (continued) Reinstall the front cover. Replace the supplied liquid lens outer cover with C-mount outer Install lens (CS-Mount lens). cover if required. C-mount cover Liquid lens cover Use CS- to C-mount adapter ring for C-mount lenses. 9 N-cm (0.8 Lb-In) Observe torque limit Tighten in...
  • Page 9: Mounting The Reader

    3. Disconnect the PoE injector from the Ethernet installation. Do not stare into beam when adding, removing, or changing cables. Cognex recommends to unpower the reader any time you make physical changes to it. 14 DataMan 500 Quick Reference Guide DataMan 500 Quick Reference Guide Artisan Technology Group - Quality Instrumentation ...
  • Page 10 Reading Distance and Field of View For the DataMan 500, two liquid lens modules are available, one 299 mm (11.7 in) with a 13.3 mm lens (DM500- LLM-013) and one with a 18.8 mm lens (DM500-LLM-018). The following images provide the 150 mm (5.9 in) supported reading distances and 75 mm (2.95 in)
  • Page 11 Reading Distance and Field of View 437 mm (17.2 in) Pages 18-19 show the data of a liquid lens with a 40 degree opening angle. Use this lens to read near objects. 218 mm (8.58 in) For CS-mount lenses, the lens’s focal length, focus setting, and aperture setting determine the field of view 109 mm (4.29 in)
  • Page 12 Install DataMan 500 Software Troubleshooting an Ethernet Connection 1. Check the DataMan Release Notes for a full list of system requirements. Based on your network configuration, the Setup Tool may not be able to communicate with the reader and it will not appear in the list 2.
  • Page 13 Start the Setup Tool Connect the reader to the Setup Tool to Trigger button Latest image Region of interest Context based help configure it with the type of symbologies it will decode as well as other parameters, such as the type of trigger it will use and the format of the results it will generate.
  • Page 14 Setup Tool, and the Tasks menu to switch between various Setup Tool the name of the device, its IP address, subnet mask, and so on. Cognex options. recommends generating a device configuration file for each reader to allow you Use the System menu to manage the current settings on the reader to restore a reader to its operating state with minimal effort.
  • Page 15: External Triggers

    DataMan 500 Triggering External Triggers modes (the modes are supported for 2D codes as well). If you are DataMan 500 supports self-triggered operation. In self-trigger mode, at an using external triggering you can use any of these methods to trigger interval you configure, the reader automatically detects and decodes codes in DataMan 500: its field of view.
  • Page 16 Training the Reader Training your reader with the expected symbology can decrease the time Training Feedback required to decode successive symbols. To train your reader, first switch The middle LED on the reader glows green to indicate that to Single mode, then place a code in front of the reader and do one of the it is currently trained, or yellow to indicate that it is not following: trained.
  • Page 17 High-Power Lighting Module Attach the lens cover to the lighting module. • Use screws removed The high-power lighting module (available as an accessory) allows you to work in Step 2. with higher line speeds and greater working distances than the built-in internal •...
  • Page 18 I/O Cable Acquisition Triggering The I/O cable provides access to trigger and high- The acquisition trigger input on the reader is opto-isolated. To trigger speed outputs. Unused wires can be clipped short or from an NPN (pull-down) type photo-detector or PLC output, connect tied back using a tie made of non-conductive material.
  • Page 19 High-Speed Output Lines The high-speed outputs can be used as either NPN (pull-down) or PNP (pull-up) For PNP lines, the external load should be connected between the output lines. For NPN lines, the external load should be connected between the output and the negative supply voltage (0V).
  • Page 20: High Speed Output Wiring

    High Speed Output Wiring To connect to an NPN-compatible PLC input, connect Output 0 or Output 1 To connect the high-speed outputs to a relay, LED or similar load, directly to the PLC input. When enabled, the output pulls the PLC input down to connect the negative side of the load to the output and the positive side less than 3V.
  • Page 21 RS-232 Cable DataMan 500 Specifications The RS-232 cable provides an optional connection between the reader and Weight TBD g your PC. Operating 0ºC — 40ºC (32ºF — 104ºF) Temperature Storage -10ºC — 60ºC (-14ºF — 140ºF) Temperature Maximum 95% (non-condensing) Humidity Environmental IP65 (with cable or protection cap attached to all connectors,...
  • Page 22 Compliance Notice radio frequency energy and, if not installed and Cognex Corporation shall not be liable for use used in accordance with the instructions, may of our product with equipment (i.e., power UL and cUL Statement cause harmful interference to radio communica- supplies, personal computers, etc.) that is not...
  • Page 23: Warnings And Notices

    • Do not attempt to service or repair this product -- return it to Cognex CAUTION: This device requires the use of a PoE Class 3 or 48V DC LPS power for service.
  • Page 24: Reset Scanner To Factory Defaults

    Reboot Scanner Factory Defaults Copyright © 2010 Cognex Corporation All Rights Reserved. This document may not be copied in whole or in part, nor transferred to any other media or language, without the written permission of Cognex Corporation. The hardware and portions of the software described in this document may be covered by one or more of the U.S.