Summary of Contents for Vanderbilt V54502-C164-A100

  • Page 1 Multi Function Interface (MFI) Technical Manual Document ID:A-100789 Edition date: 31.08.2022...
  • Page 2 Hereby, Vanderbilt International (IRL) Ltd declares that this equipment type is in compliance with the following EU Directives for CE marking: •...
  • Page 3: Table Of Contents

    2.1 Installation 2.2 Connections and LED's 2.2.1 Connections related to Doorset 2.2.2 OSDP Reader Wiring 2.2.3 Wiring of Monitored input 2.2.4 LED's 2.3 Configuration and Firmware Download 2.4 Cable Specifications 2.5 Addendum Document ID: A-100789 © Vanderbilt 2022 Edition date: 31.08.2022...
  • Page 4: General Information

    Please take into account any additional country-specific, local laws, safety standards or regulations concerning installation, operation and disposal of the product. Refer to a qualified electrician for installation. 1.2 Details of ordering Type Item Number Description V54502-C164-A100 MFI -SiPass Multi-Function Interface Document ID: A-100789 © Vanderbilt 2022 Edition date: 31.08.2022...
  • Page 5: Product Description

    - 40 C to +55 C Dimensions 239 × 156 × 53 mm (W × H × D) 630 grams Weight Tamper switch Opening tamper switch and removal tamper switch Environmental class II, IEC 60839 -11-1 Document ID: A-100789 © Vanderbilt 2022 Edition date: 31.08.2022...
  • Page 6: Multi-Function Interface Module

    Jumper on the two lower pins – EOL OFF. Reader type selector Only OSDP protocol is supported by default (no jumper required). Opening tamper switch Detects if the lid is removed. Not used © Vanderbilt 2022 Document ID: A-100789 Edition date: 31.08.2022...
  • Page 7 IN 2, 4, 6, 8 - Door contact 22 - 29 Relay outputs RLY 1, 2, 3, 4 - Door lock / strike relay driven output RLY 5, 6, 7, 8 - Auxiliary Relay Outputs © Vanderbilt 2022 Document ID: A-100789 Edition date: 31.08.2022...
  • Page 8: Scope Of Delivery

    1.7 Scope Of Delivery 1 x MFI board with required resisters and jumpers. 1 x installation manual English. © Vanderbilt 2022 Document ID: A-100789 Edition date: 31.08.2022...
  • Page 9: Installation

    Alternatively, the firmware and configuration may be carried out using the FLN Field Service Tool Version 2.5.3 or later. © Vanderbilt 2022 Document ID: A-100789 Edition date: 31.08.2022...
  • Page 10: Connections And Leds

    10. Check all jumpers. 11. Check all connections thoroughly, including the polarity of each connection. Once you have verified all connections power can be applied to the MFI. © Vanderbilt 2022 Document ID: A-100789 Edition date: 31.08.2022...
  • Page 11: Osdp Reader Wiring

    AUX OUT 1 H719 White AUX OUT 2 H720 White AUX OUT 3 H721 White AUX OUT 4 H722 White INPUT status LEDs H700 to H707 Red (During tamper) Green (Normal) Orange (Alarm) © Vanderbilt 2022 Document ID: A-100789 Edition date: 31.08.2022...
  • Page 12: Configuration And Firmware Download

    The MFI is configured using SiPass Configuration client, through the ACC-AP AP01P, or using the ACC and FLN Field Service Tool. Refer to the Controller and Device Installation Guide for more Information. Document ID: A-100789 © Vanderbilt 2022 Edition date: 31.08.2022...
  • Page 13: Cable Specifications

    Aluminium foil - Copper Polyethylene Polyester tape / braided shield 7 x 32 Tinned Copper 7 x 32 Tinned Copper 19 x Power (12/24 Tinned Foam Unshielded V DC) Copper Polyethylene © Vanderbilt 2022 Document ID: A-100789 Edition date: 31.08.2022...
  • Page 14: Addendum

    To enable EOL on MFI’s reader connection port (Refer section 3.1 Description of Numbered Items in the Diagram - Item Number 4a) To enable EOL on ACC-AP’s MFI communication port (Refer ACC-AP Technical Manual) © Vanderbilt 2022 Document ID: A-100789 Edition date: 31.08.2022...
  • Page 15 Sample wiring between MFI and readers: ……………………… Up to 8 ……………………… Reader1 Reader2 Reader 3 readers ……………………… Note: If Vanderbilt NGCR Readers like VR40S-MF, VR10S-MF are used - EOL must always be enabled on MFI. Document ID: A-100789 © Vanderbilt 2022 Edition date: 31.08.2022...
  • Page 16: Document Id: A-100789

    © Vanderbilt 2022 Data and design subject to change without notice. Supply subject to availability. Document ID: A-100789 Edition date: 31.08.2022 Issued by Vanderbilt International Ltd. Clonshaugh Business and Technology Park vanderbiltindustries.com Clonshaugh, Dublin D17 KV 84, Ireland @VanderbiltInd Vanderbilt Industries...