Hygeia 20-0115 Manual

Personal accessory set (pas)

Advertisement

Available languages

Available languages

Hygeia Personal Accessory Set (PAS)
Item# 20-0115
ART-70307-01-AC
Hygeia © 2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 20-0115 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hygeia 20-0115

  • Page 1 Hygeia Personal Accessory Set (PAS) Item# 20-0115 ART-70307-01-AC Hygeia © 2023...
  • Page 2 PLEASE READ AND SAVE THESE INSTRUCTIONS 1. Intended Use The Hygeia Personal Accessory Set (PAS) is intended to be used by lactating women to express and collect milk from their breasts. This product is intended for a single user only and should not be shared between users.
  • Page 3: Standard Reference

    1:2005/ (R) 2012 Medical Follow Electrical Instructions equipment- Part for Use 1: General requirements for basic safety and essential performance Hygeia II Medical Group, Inc 6241 Yarrow Drive, Suite A Carlsbad, CA 92011 USA Hygeia © 2023 ART-70307-01-AC...
  • Page 4: Important Safeguards

    NOTE: Inspect the tubing. If you find condensation in the air tube, wash and dry it immediately or replace the tubing. If you see breast milk inside the tubing or tubing connector do not attempt to wash, clean or sterilize the tubing or tubing connector. Instead contact Hygeia Customer Service at 714-515-7571 Option #2. IF YOU DISINFECT BY BOILING DO NOT allow boiling parts to contact bottom of pot.
  • Page 5 If milk is present in the tubing, do not attempt to wash or clean the tubing. Instead contact Hygeia Customer Service at 714-515-7571 Option #2. HOW TO WASH TUBING: 1.
  • Page 6: After Cleaning

    Do not use a dish towel to rub or pat items dry! AFTER CLEANING 1. FOR EXTRA PROTECTION, DISINFECT Hygeia © 2023 ART-70307-01-AC...
  • Page 7 NOTE: Inspect the tubing. If you find condensation in the tubing, wash and dry it immediately or replace the tubing. If you see breast milk inside the tubing or tubing connector do not attempt to wash, clean or sterilize the tubing or tubing connector. Instead contact Hygeia Customer Service at 714-515-7571 Option #2.
  • Page 8 4. Hygeia Personal Accessory Set (PAS) Components and Materials All parts of the PAS Kit are not made with BPA or DEHP. Number Name Material Flange Funnels 28mm and 24mm included Polypropylene (PP) Flange Base Polypropylene (PP) Valve, Duckbill Silicone...
  • Page 9 1. Attach the Flange Funnel to the Flange Base 2. Attached the Duckbill Valve into the bottom of the Flange base. 3. Assemble the Backflow protector case bottom, Backflow protector Silicone diaphragm and Backflow protector case top. Yo are properly fitted together. Hygeia © 2023 ART-70307-01-AC...
  • Page 10 4. Connect the 3-piece assembled Backflow protector to the top of the Flange Base pushing in firmly. 5. Add the Assembled Flange Funnel, Flange Base and Duckbill valve onto the storage container. Hygeia © 2023 ART-70307-01-AC...
  • Page 11 If double pumping, place the second breast shield in place as well. Hygeia © 2023 ART-70307-01-AC...
  • Page 12 While some discomfort may be felt when first using a breast pump, using a breast pump should not cause pain. If you are unsure about breast shield sizing, please contact a healthcare professional or Hygeia representative who can help you get a proper flange fit.
  • Page 13 2 hours. If you have any leftover milk when the baby is finished feeding, be sure to throw it out within 2 hours. Do not refreeze breastmilk after it has been thawed. Hygeia © 2023 ART-70307-01-AC...
  • Page 14: Troubleshooting

    Low Suction Press the flange against breast to create a seal. DO NOT use the Personal Accessory Set with the Hygeia EnJoye or Hygeia EnDeare breast pumps as low suction will result. Break the seal on the flange funnel by inserting a finger between the breast and Pain or Flange Funnel.
  • Page 15 Kit de Accesorios Personales Hygeia (PAS) Artículo# 20-0115 Hygeia © 2023 ART-70307-01-AC...
  • Page 16 Compatibilidad del Extractor de Leche El PAS debe estar conectado correctamente al extractor de leche eléctrico Hygeia Express, a los extractores de leche Hygeia Evolve o Hygeia FIT Pro como se muestra en la sección 5, Pasos para Instalación. El kit de accesorios personales Hygeia (PAS) solo es compatible con el extractor de leche eléctrico Hygeia Express, los extractors de leche Hygeia FIT, Hygeia FIT Pro ó...
  • Page 17 Fabricante Indica el 5.1.1 ISO 15223- fabricante del 1:2016 dispositivo Dispositivos médico. médicos- Símbolos que se utilizarán con las etiquetas de los dispositivos médicos, el etiquetado y la información que proporcionará- Parte 1: Requisitos generales Hygeia © 2023 ART-70307-01-AC...
  • Page 18: Salvaguardas Importantes

    Fabricante: Hygeia II Medical Group, Inc 6241 Yarrow Drive, Suite A Carlsbad, CA 92011 USA SALVAGUARDAS IMPORTANTES No use el extractor de leche materna cuando conduzca. Usar el extractor de leche durante el embarazo puede inducir el parto, no lo use durante el embarazo.
  • Page 19 Si hay leche en la manguera, no intente lavarla o limpiarla. En su lugar, comuníquese con el servicio de atención al cliente de Hygeia al 714-515-7571 Opción #2. CÓMO LAVAR LA MANGUERA: 1.
  • Page 20 En su lugar, comuníquese con el servicio de atención al cliente de Hygeia al 714-515- 7571 Opción #2 para obtener un reemplazo.
  • Page 21 Deben estar completamente secos para ayudar a prevenir la multiplicación de microbios y el moho. Guarde los artículos secos en un lugar limpio y protegido. Hygeia © 2023 ART-70307-01-AC...
  • Page 22 Si observa leche materna dentro de la manguera o del conector de la manguera, no intente lavar, limpiar o esterilizar la manguera o el conector de manguera. En su lugar, comuníquese con el Servicio al Cliente de Hygeia al 714-515- 7571 Opción #2.
  • Page 23 FIT Pro (PP) Conector para manguera exclusivo del extractor de Polipropileno (PP) leche eléctrico Hygeia Express 5.5Pasos para Instalación Conecte la de copa de succión a la base de la copa Hygeia © 2023...
  • Page 24 Se debería escuchar un "clic" una vez que las piezas se hayan colocado correctamente. Conecte el protector de contra reflujo ensamblado de 3 piezas a la parte superior de la base de copa presionando firmemente. Hygeia © 2023 ART-70307-01-AC...
  • Page 25 Conecte la manguera a la parte posterior del protector de reflujo Conecte el adaptador de manguera a su extractor de leche Fit Pro. Conecte el conector para manguera a su extractor de leche eléctrico Hygeia Express. Hygeia © 2023 ART-70307-01-AC...
  • Page 26 Si no está segura sobre el tamaño de la copa de succión, comuníquese con un profesional de la salud o un representante de Hygeia que pueda ayudarla a obtener un tamaño adecuado de copa.
  • Page 27 La leche materna no necesita ser calentada. Algunas madres prefieren utilizarla fría ó a temperatura ambiente. Descongele la bolsa de leche congelada dejandóla en el refrigerador durante la noche. No congele el biberón, solo congele la bolsa de almacenamiento de Hygeia © 2023 ART-70307-01-AC...
  • Page 28 El Kit de accesorios personales Hygeia es el conjunto de accesorios previsto para el extractor de leche eléctrico Hygeia Express y los extractors de leche Hygeia FIT, Hygeia FIT Pro ó Hygeia Evolve únicamente. Los kit de accesorios personales diseñados para los extractores de leche Hygeia EnJoye o Hygeia EnDeare no son compatibles ni están diseñados para usarse con el extractor de leche...
  • Page 29 Hygeia Express y los extractores de leche Hygeia FIT, Hygeia FIT Pro o Hygeia Evolve. El uso de Hygeia EnJoye o EnDeare PAS con el extractor de leche eléctrico Hygeia Express, Hygeia FIT, Hygeia FIT Pro ó Hygeia Evolve anulará la garantía del extractor, podría provocar que la leche entre en el extractor y posiblemente provocar lesiones personales debido a los altos niveles de succión.

Table of Contents