Turbines HA Series Installation & Operation Manual

High accuracy turbine flow meter

Advertisement

Quick Links

This document contains the recommende
Turbines, Inc., the manufacturer of the refe
installation procedures, or use that is abu
equipment is permitted hereunder, and ma
or effective.
In the event installers or end users require
the address indicated below. Technical qu
subject equipment.
HIGH ACC
ded installation, operation and maintenance regimen authorize
referenced equipment. No substitutions of specified componen
busive or outside the specified range or capability specification
may, if evident or present, serve to void any warranties that mi
ire additional assistance and/or clarification in any respect, co
questions must be accompanied by proper product model num
HA SERIES
CURACY TURBINE F
METER
zed and approved by
ents, improper handling or
ions of the referenced
might otherwise be operative
contact the manufacturer at
umber and serial number of
E FLOW
DOCUMENT
T NUMBER: HA-MANUAL REV-A

Advertisement

loading
Need help?

Need help?

Do you have a question about the HA Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Turbines HA Series

  • Page 1 This document contains the recommende ded installation, operation and maintenance regimen authorize zed and approved by Turbines, Inc., the manufacturer of the refe referenced equipment. No substitutions of specified componen ents, improper handling or installation procedures, or use that is abu...
  • Page 2 Please do not hesitate to contact an applications ns specialist at Turbines, Inc. should further information or clar larification be necessary. Be sure to have the model and ser serial number of the subject equipment ready when you call or c r contact us via e-mail.
  • Page 3: Meter Installation

    METER RUN ARRANGEMENT GENERAL PIPING CONSIDER ERATIONS Turbines, Inc. recommends the following s g standard flow metering piping configuration to obtain opt ptimum metering As explained in earlier sections s, the line fluid moving performance.
  • Page 4 4 in-lb. meter will cause the performance to b become non-linear. Pickup coils for Turbines, Inc. Turbine Flow Meter ters are LIQUID FLOW CHARACTERISTICS designed to mate with a two pin MS3106A-10SL- connector.
  • Page 5: Installation

    All Turbines, Inc. Turbine Flo low Meters are factory calibrated based on this calibration ion procedure in...
  • Page 6 Should evidence of such co conditions be present, it is recommended that the meter be ret returned to the factory to The standard design for Turbines, Inc. High Accu curacy be rebuilt. Turbine Flow Meters consists of stainless steel in internal components.
  • Page 7 RE-ASSEMBLY Disassembly and Asse sembly Step 1 Internal components must be re e reassembled in the same An exploded view of the internal componen nents is provided in orientation as they were remov oved. Figure 4. Additional assistance, if required ed, may be obtained by contacting the factory.