Download Print this page

Speakman Safe-T-Zone STW-SC1 Instructions For Use

Cabinet for small thermostatic mixing valve stw-370

Advertisement

Quick Links

INSTRUCTIONS FOR MODELS
STW-SC1
Cabinet for Small
Thermostatic Mixing Valve
(STW-370)
For additional assistance or service please contact:
SPEAKMAN
®
Company
400 Anchor Mill Road
New Castle, DE 19720
800-537-2107
customerservice@speakman.com
www.speakman.com
92-STW-SC1-01
3
Insert the Cabinet in the rough in opening.
Make sure it is level. If it doesn't fit, adjust the
hole opening.
7
Insert the COLD inlet into the support Bracket
as shown below. Ensure that the Flange of the
COLD inlet is positioned above the Bracket (2).
TOOLS AND SUPPLIES
Pencil
Level
Measuring
Tape
Utility
Caulk Gun
Phillips
Knife
Screwdriver
Mounting Hardware
(not included)
HELPFUL TOOLS & SUPPLIES:
Stud Finder
Safety
Glasses
Keyhole
Saw
4
Knock out required holes to secure Left Side
of Cabinet and Right Side of Cabinet to wall
with four 1/4" fasteners properly anchored
(supplied by installer.) Ensure the mounting
surface (wall, etc.) and mounting hardware
can safely support the product in use.
8
Rotate the Valve Assembly and insert the HOT
inlet into the Bracket ensuring that the Flange of
the HOT inlet is positioned above the Bracket as
shown below (3).
IMPORTANT
• Ensure the mounting structure and mounting
hardware can safely support the product in use.
• Do not over-tighten any connections or damage
may occur.
• Be sure to read instructions thoroughly before
beginning installation.
SAFETY TIPS
Be sure to wear eye protection.
MAINTENANCE
Your new Speakman Product is designed for years
of trouble-free performance. Keep it looking new by
cleaning it periodically with a soft cloth. The use of
harsh chemicals and abrasives on any of the
Speakman custom finish products may damage the
finish and void the product warranty. Please be
sure to only use approved cleaners. Please contact
Speakman for any clarification of acceptable
cleaners.
WARRANTY
Additional warranty information can be found at:
www.speakman.com
5
Install mounting hardware through the six (6)
mounting locations into a secure brace (supplied
by installer) or into wall. This will support the
Valve. Ensure the mounting structure and
mounting hardware can safely support the
product in use.
9
Position the Flange Trim tight to the wall and
caulk it in place.
1
SURFACE MOUNTED CABINET
Determine desired mounting position of Cabinet and
Valve. Ensure mounting location and mounting
hardware are capable of supporting the product in use.
Mark the six (6) mounting locations onto surface.
2 1
"
6X
8
55mm
1 1
"
4
8 1
31mm
"
2
216mm
4 1
2
115mm
7"
178mm
2"
51mm
SKIP TO STEP 5
2
RECESS MOUNTED CABINET
Ensure proper mounting structure is present within the
wall cavity. Measure and cut out wall opening using
appropriate tools.
11.25in
286mm
6
Insert the Valve into the support Bracket of the
Cabinet. Right side goes in first (1).
5
"
8
15mm
"
12.75in
324mm

Advertisement

loading
Need help?

Need help?

Do you have a question about the Safe-T-Zone STW-SC1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Speakman Safe-T-Zone STW-SC1

  • Page 1 Safety MAINTENANCE Glasses Ensure proper mounting structure is present within the Your new Speakman Product is designed for years wall cavity. Measure and cut out wall opening using of trouble-free performance. Keep it looking new by appropriate tools. cleaning it periodically with a soft cloth. The use of...
  • Page 2 SPEAKMAN STW-SC1 RECESSED MOUNT ROUGH-IN DIAGRAM ® " 2" " 51mm 105mm 87mm * VALVE NOT INCLUDED. VALVE SHOWN FOR REFERENCE ONLY. " 44mm 12 7 " 14 1 " 327mm " 2" 368mm 8 " 8 11 51mm "...