Page 1
WARNING: Look inside the top canister for the mounting bracket. The mounting bracket is inside the foam in the top canister. Central Vacuum System User Manual ST-600-18B Dealer/Installer Name Dealer Phone # Serial Number Date Installed NAUM-EN-NAD-ST-18B-12-31-2024...
Index 1. Important safety instructions ..................2. General guidelines and references ................Grounding requirements General guidelines to be respected at all times 3. Models / Disposable filtration bags ................4. System operation instructions ..................5. Filtration system maintenance ..................6. Trouble shooting ......................7 - 8 7.
1. IMPORTANT SAFETY INSTRUCTIONS CAREFULLY READ ALL OF THESE INSTRUCTIONS BEFORE USING THIS CENTRAL VACUUM SYSTEM. When using an electrical appliance, it is necessary to observe certain basic precautions. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY: Unplug the power cord from the electrical outlet before performing any maintenance on the power unit.
To speci cations. This appliance should not be used with an optimize the performance and lifespan of your Nadair power adapter. While it is recommended to install this unit on its unit, it is essential to perform regular maintenance and independent circuit and breaker, it is not necessary to do so.
- Permanent protective filter must be replaced once every one (1) year in order to maintain the warranty on the vacuum. The new filter must be NADAIR filter: FILPCDO-VAC. - The disposable bags for this model are: FD-12.5L-3NAD. The power unit must be installed in a well-ventilated area, protected from the weather. It must be easily accessible and positioned away from any heat source.
FILTRATION BAGS IMPORTANT This Nadair central vacuum unit must be used with a filtration bag, and the permanent protective filter must be in place AT ALL TIMES. Bags are sold in 3-pack: FD-12.5L-3NAD. The disposable bag must be installed as described here:...
6. TROUBLE SHOOTING GENERAL The following may cause failure of the power unit: - Inadequate electrical power (Voltage or Amperage). Verify that the electrical power supplied complies with the power unit’s requirement - Abnormal performances of the electronic control module or the motor Before calling a service technician, in case of a malfunction, please review the following situations by running the following simple diagnostics: SITUATION...
Page 8
The unit should start. Remove the wire and wait 3 seconds. The unit should stop. For more troubleshooting tips or answers to your questions, visit our website. USA: www.nadair.com/trouble-shooting CANADA: www.nadair.ca/trouble-shooting Page 8...
7. LOW-VOLTAGE SYSTEM TECHNOLOGY LED status interpretation guide This Nadair Central Vacuum Power Unit is provided with an LED status indicator to Reading the following table will allow you to identify the status of your appliance by For models with no reset...
Page 10
The Central Vacuum Power Unit Body, Motor & Module – Ten (10) years: Nadair will repair or replace any defective parts of the central vacuum motor, electronic module, body, housing, and dust bin for ten (10) years, as long as you own it, and if used in normal conditions and properly maintained, as stated in the power unit instruction manual.
Need help?
Do you have a question about the ST Series and is the answer not in the manual?
Questions and answers