Contents Product Overview Components Connections Suitable Cable Lengths System Block Diagram Controls Hearing Loop Set Up Mechanical/Mounting Output Voltage vs Supply Voltage Standards...
Product Overview Designed for smaller facilities such as meeting rooms, classrooms, and similar-sized venues, the ID-7 incorporates a 75V line input for • Discreet and compact design • Wide operating power supply range (12V-24V DC only) • High output voltage (7Vrms – 15V)*, allowing large hearing loops to be driven •...
Page 6
This input can be used with balanced microphone and single ended should be connected as follows: • • should be connected as follows: • Mic + (Hot) to pin 2 (+) • Mic – (Cold) to pin 3 (-)
Page 7
1 (COM) should be connected between pin This connection allows two ID-7’s to be connected to create a ID-7’s should be connected as follows: • Signal Return (Cold) to pin 1 (GND) • Signal (Hot) to pin 2 (SIG)
Page 8
When operating in this mode the signal source should be Mute signal for fast disable/enable of outputs:...
Page 9
• HIGH (Greater than 6V) = outputs OFF (high-Z) • LOW = outputs ON...
Page 10
The ID-7 can operate from direct current (DC) power supply...
Controls (High Frequency Compensation) allows the frequency Rotating the control clockwise increases the amount of HF Comp applied (increases the high frequency whilst reducing the lower Rotating the control counterclockwise reduces the amount of HF (Microphone Input Gain) allows the adjustment of the Rotating the control clockwise increases the gain of the Rotating the control counterclockwise reduces the gain of the Rotating the control clockwise increases the level of the line input...
Page 16
Rotating the control clockwise increases the current available from Rotating the control counterclockwise reduces the current...
Hearing Loop Set Up To ensure optimal performance of a ID-7 hearing loop driver, setup should be performed in following order: : Metal Loss (see below) : Output Level and Clipping (see page 19) : Field Uniformity (see page 19)
Page 19
5000Hz is , record the results and move on to Step 2: rotate the HF comp adjustment 1000Hz and 5000Hz is less than 3dB, record the results and move lower than 0dB then increase the drive level and if too high reduce With the level now set in the centre of the loop, move the Field Strength Meter to other user positions within the looped area and...
Standards induction loop drivers up to 45 amperes in the frequency range 10Hz...
Page 25
This product has been designed and tested to comply with the following • • following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including Systems LTD or an authorised partner could void the user’s authority to This marking indicates that this product should not be disposed with other environment or human health from uncontrolled waste disposal and to dispose of your product, please use your local return and collection systems...
Page 26
Local dealer: UK & ROW US & Canada +44 (0) 1732 223900 +1 616 392 3400...
Need help?
Do you have a question about the ID-7 and is the answer not in the manual?
Questions and answers