Hello The Lightcloud Blue Wireless Switch can be used to control hundreds of Lightcloud Blue-enabled lights— no Gateway or Hub required, and no need to run any additional wires. All communication for on/off, dimming, and occupancy sensing happens wirelessly via Bluetooth Mesh.
Safety Information • To avoid risk of fire and electrical shock, products shall be installed in accordance with electrical code and regulations. • If you’re not clear about any content of the instructions, please consult a licensed electrician. • To avoid the risk of overheating and possible damage to the equipment, do not use the product to control a receptacle, motor-operated appliance or a transformer-supplied appliance.
Parts Included and Tools Needed Parts Included Wireless Switch Wireless Switch with Sensor ZDIM/LCB (1 pcs) ZDIM/LCBS (1 pcs) Mounting Screws (2 pcs) Front Back Face Plate Cover Plate (1 pcs) (1 pcs)
Basic Operation Replaceable Control Component • The Power component is the base of the unit that is hardwired into a standard wall box. • The Control Component can detach from the Power component by pulling the Power Cutoff Switch until the stops. Power Component Control Component...
Basic Operation (cont’d) On/Up Paddle • Turn lights ON: Single press • Increase brightness: Press and hold, release at desired setting • Increase to maximum brightness level: Double press Off/Down Paddle • Turn lights OFF: Single press • Decrease brightness: Press and hold, release at desired setting •...
Page 9
Installing your Lightcloud Blue Device Find a Suitable Location • Lightcloud Blue devices should be positioned within 60 ft. of each other. • Building materials such as brick, concrete and steel construction may require additional Lightcloud Blue devices to extend around an obstruction. Add an additional Lightcloud Blue Device to extend network range...
Installing your Lightcloud Blue Device (cont’d) Turn off Power WARNING • Place the wall switch in the off position. • Turn off the main power at the breaker panel or remove the fuse from the fuse box. Remove Existing Switch •...
Page 11
Installing your Lightcloud Blue Device (cont’d) Group Wireless application (1 Area on the App with multiple ZDIM/LCB[S] to control one load) Green screw Ground Cupreous screw ZDIM/ LCB[S] Silver screw Black (Neutral) screw Neutral Green Green screw screw Ground Ground Cupreous Cupreous screw...
Page 12
Installing your Lightcloud Blue Device (cont’d) Install and Fix the Wireless Switch • Ensure the Control Component is attached to the Power Component. Carefully position all wires inside the wall box, leaving enough room to insert the Wireless Switch. Secure the Wireless Switch to the Wall Box with the mounting screws provided.
Page 13
Installing your Lightcloud Blue Device (cont’d) • Connect the face plate to the installed back plate and gently push it until it clicks into place. Be sure to align the divets on the back and face plate to make it easier to remove the faceplate when needed.
Page 14
Controlling your Lightcloud Blue Device Confirm your device is powered on. Download the Lightcloud Blue app from the Apple® App Store or Google® Play store. Launch the app and create an account. Tap the "add device" icon in the app to start connecting devices.
Page 15
Setting Device to Pairing Mode To restore your Lightcloud Blue Wireless Switch to factory settings, use the following methods. Method 1: Delete from App Open the app and access the device settings for the paired device. Be sure that the Wireless Switch is online and select "Delete from Site".
Sensor Detection Range Best mounting height of dimmer: 4ft. Maximum horizontal detection range 26.25ft 19.69 13.12 6.56 6.56 13.12 19.69 26.25ft Maximum vertical detection range 6.56 13.12 19.69 26.25ft Functionality Configuration All configuration of Lightcloud Blue products is performed using the Lightcloud Blue app. Emergency default If communication is lost, the Lightcloud Blue Wireless Switch may fall back to a specific state, such as turning the Lightcloud Blue lights on.
Page 17
RF EXPOSURE STATEMENT This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body. FCC Information: This device complies with Part 15 of the FCC Rules.
Page 19
Installing your Lightcloud Blue Device (cont’d) Typical Wiring Single-Pole Wiring Scheme (neutral and hot wire) Green screw Ground Line Silver screw Black screw Wireless Switch Neutral Wireless Switch Location 1 Green screw Tagged Wire Silver screw Black screw To breaker Black White Ground...