70.7 / 100v transformers

Advertisement

ARCHITECTS & ENGINEERS SPECIFICATION
The transformers shall be Altec Lansing Professional model numbers T560-71 and T5100-71, rated at 60 Watts and 100 Watts, respectively.
Their frequency response shall be 35 Hz to 15,000 Hz, ±0.5 dB. Throughout their 35 Hz to 15,000 Hz bandwidth, at rated power, they shall
produce no more than 0.5% T.H.D., and their insertion loss shall not exceed 1 dB. These transformers shall require no more than 10%
above their rated input power to deliver rated power to the load at 35 Hz. The T560-71 and T5100-71 shall provide true electrical
isolation to the source and to the load. Connection to these transformers shall be through 0.25-inch blade type wire terminals. The
nominal primary taps shall be 4 ohm and 8 ohm, and the nominal secondary taps shall be 70.7V and 100V.round white metal
voltage ratio
4 Ohm
to 70 V
T560-71
1:4.5
T5100-71
1:3.5
impedance ratio
4 Ohm
to 70 V
T560-71
1:20.8
T5100-71
1:12.5
wiring diagram
100 V
70.7 V
COMMON
E5475 REV01
4 Ohm
to 100 V
1:6.4
1:5.0
4 Ohm
to 100 V
1:41.7
1:25.0
8 Ω
4 Ω
COMMON
© 2002 Altec Lansing Professional
1000 W. Wilshire Blvd., Suite 362
Oklahoma City, Oklahoma 73116
Phone: 1-405-848-3108 • Fax: 1-405-848-3217
Web: www.altecpro.com • Email: proinfo@alteclansing.com
8 Ohm
8 Ohm
to 70 V
to 100 V
1:3.2
1:4.6
1:2.5
1:3.5
8 Ohm
8 Ohm
to 70 V
to 100 V
1:10.4
1:20.8
1:6.3
1:12.5
P
R O F E S S I O N A l
grille.E
4/8 term
4/8 term
to 70 V
to 100 V
1:10.9
1:15.4
1:8.5
1:12.0
4/8 term
4/8 term
to 70 V
to 100 V
1:21.9
1:44.0
1:13.1
1:27.0

Advertisement

loading

This manual is also suitable for:

T560 transformerT560-71T5100-71