Koso 3610 Series Operating Instructions Manual
Koso 3610 Series Operating Instructions Manual

Koso 3610 Series Operating Instructions Manual

Angular travel electronic actuator

Advertisement

Quick Links

3610-Series Angular Travel Electronic Actuator
Operating Instruction
Manual
KOSO CONTROL INSTRUMENT (ANSHAN) CO.,LTD.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3610 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Koso 3610 Series

  • Page 1 3610-Series Angular Travel Electronic Actuator Operating Instruction Manual KOSO CONTROL INSTRUMENT (ANSHAN) CO.,LTD.
  • Page 2 ★Actuating unit self-locked after power is off. ★Protection functions of 3610 series electronic actuator: ①Overload protection unit: Type A and B of 3610 series actuator are optional and Type C and D are necessary. When the motor current is too great for valve locked or...
  • Page 3 Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator protection role. After the malfunction is removed, the actuator will operate normally again. ②Temperature protection: Temperature protection switch is installed in the motor. When the temperature in the motor exceeds the allowable temperature, the switch will act and automatically shut off the winding power so as to protect the motor from being burnt out.
  • Page 4 Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator S a f e t y N o t e s F o r t h e s a f e a c c e p t a n c e , t r a n s p o r t a n d s t o r a g e , i n s t a l l a t i o n , f u n c t i o n i n g p r e p a r a t i o n a n d f u n c t i o n i n g , m a i n t e n a n c e o f t h e e l e c t r i c a c t u a t o r , c o r r e c t u s e a n d r e g u l a r m a i n t e n a n c e i s n e c e s s a r y .
  • Page 5: Table Of Contents

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator Contents 1. Technical parameters 1.1 Meanin g of produ ct mo del 1.2 Structure 1.2.1 Structural diagram of common 361 1.2.2 Structural diagram of explosion-proof 361 1.3 Main technical parameters 1.4 Installation dimensions 1.4.1 Installation dimension diagram 1.4.2 Installation method and dimension diagram of RSA, RSB, RXB models with base and crank 5 1.4.3 Installation method and dimension diagram of RSC and RXC models with base and crank...
  • Page 6 Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator 5.2.1 Zero point adjustment 5.2.2 Range adjustment 5.2.3 Sensitivity adjustment 5.3 Fu n c t i o ni n g 5.3.1 Manual operation 6. Daily inspection and regular inspection 6.1 Da i l y i n s p e c t i o n 6.2 Reg ular insp ect ion 1 ~...
  • Page 7: Technical Parameters

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator 1. Technical Parameters 1.1 Meaning of product model — ※ U Angular travel with base crank (optional) Sign of space heater (optional) Sign of angular travel moment switch (optional) Overload protection unit (Type A and B optional, Type C and D necessary) Optional sign Denote output moment, see table (1.1) for detail...
  • Page 8: Structure

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator 1.2 Structure 1. 2.1 St ructur al di agra m of common 361 Name Shell Worm-gear case Actuator rack Cover Cover lock ring Output shaft Worm gear Worm Catch bolt Driving wheel Follower Cover pressure plate Cover bolt...
  • Page 9: Structural Diagram Of Explosion-Proof 361

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator 1.2.1 361 普 通 型 结 构 图 ( 1。 1 ) 1.2.2 St ruct ural di agra m of explos i on-proof 361 Name Shel l Cove r Outp ut shaft Pote ntiometer Manu al shaft Lini ng...
  • Page 10: Main Technical Parameters

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator 1.3 Main technical parameters Tabl e 1.2 It em Name Content of pa ramet er Input si gnal 4 - 2 0 m A d · c or 1 - 5 V d · c 4 - 2 0 m A d ·...
  • Page 11: Installation Dimensions

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator 1.4 Dimension for installation 1.4.1 Installation dimension diagram 2-G1/2 Explosion-proof 2-G3/4 Fi gur e 1.3 Tab le 1.3 Weight Model d2 d3(f8) □J (kg) 361RSA 225 260 185 120 65 □16 12 200 φ160 85 361RSB 255 290 225 155 65...
  • Page 12: Installation Method And Dimension Diagram Of Rsc And Rxc Models With Base And Crank

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator Table 1.4 Weight Model (kg) 4-φ13 361RSA 21 100 130 φ160 φ16 4-φ13 361RSB 21 100 130 φ320 φ16 4-φ13 361RXB 21 100 130 φ320 φ16 Not e : In the ta bl e , H2 is the di m e n s i o n ne c e s s a r y fo r re m o va l of co v e r and R is the di m e n s i o n fo r ma n u a l op e r a t i o n , whi c h sh o u l d be con s i d e r e d in th e de s i gn of ins t a l l a t i o n.
  • Page 13: Operating Principle

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator Table 1.6 D W (kg) Model 341RSD 65 305 45 310 365 170 390 464 390 85 25 180 121 φ400 φ20 12-φ14 285 470 341RXD 65 305 30 310 365 170 390 464 390 85 25 180 121 φ400 φ20 12-φ14 285 470 Not e : In the ta bl e , H2 is the di m e n s i o n ne c e s s a r y fo r re m o va l of co v e r and R is the di m e n s i o n fo r ma n u a l op e r a t i o n , whi c h sh o u l d be con s i d e r e d in th e de s i gn of ins t a l l a t i o n.
  • Page 14: Storage

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator 3.2 Storage ● St or e in the ori gin al pac kage bef ore the ins tal l at ion. ● Avoi d st ori ng in the fol low i ng pl aces : (1) Pl ace whi ch is subj ect to rain (2) Hig h-t empe rat ure envir onm ent above 60 ℃...
  • Page 15: Space For Installation And Maintenance

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator Space for installation and maintenance 4.1.2 Maint ena nce space for adjus t ment and inspe cti on shoul d be ful ly res erved . In addit i on, enough space shoul d be res erved at the si de of manual operat i ng unit to faci li ta te manual ope rat io n.
  • Page 16: Wiring Construction Of Common Actuator

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator ● Do not clam p the power li ne when co veri ng the en d cap, or ther e is a ri sk of ove r curr ent and the machi ne may be damage d. ●...
  • Page 17 Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator Fig. 4.3 No lead-in Table 4. 1 List of matching gaskets and gasket rings (supplied accessories) Gasket di ame ter D φ 10 φ 11 φ 12 φ 13* Gasket ring diam et er d φ...
  • Page 18: Rol E Of Each Funct Ion Sel Ecti On Swi Tch

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator and let t ers on the ter mi nal wi ri ng board. 11) Pu t the cover on the shel l upri ght , sl ight l y str ik e wi th rubber ha mme r to fas ten the cover scr ews alt er nati vel y an d at the same ti me ensur e the cl ear ance betw een the cove r and shel l reduce d evenl y.
  • Page 19: Functioning Debugging And Functioning

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator Ta ble 4.2 Caliber of Code number 4φ Model butterfly □J of bracket valve 361RSA-05 50-100 361RSA-05 125-200 361RSB-10/20 125-200 361RSB-10/20 250-350 361RSC-30 250-350 361RSC-30/50/60/80 400-500 361RSD-100/150/160 550-1000 Note: If the dimension of valve □ J is less than that of wiring board, mat can be added. The bracket in the table is of standard model, which can be customized according to users.
  • Page 20: Zero Point Adjustment

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator 5. 2.1 Zero po int adj ust ment L oos en the cam scre ws of low er li mi t swi tc h to make them fre e st ate . Adjus t zero point poten ti omet er wit h speci al Clamping screw smal l scr ewdr iv er: when pot ent io met er is turne d anti cl ockw is e, the output shaf t wi ll tur n cloc kwi se.
  • Page 21: Functioning

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator 5.3 Functioning Warning ● When adjust ment and ins pecti on is no t re quire d, cl ose the connect ion ho od. ● In addi ti on, if the machi ne functi ons wi th the end cap open, there is a ris k of be ing entangl ed int o the ma chine or elec tri c shock.
  • Page 22: Daily Inspection And Regular Inspection

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator 6. Daily inspection and regular inspection 6.1 Daily inspection Note ● For dai l y inspect i on, the not es of Item 5 funct ioni ng de bugging and functi oni ng mus t be fol low ed.
  • Page 23: Identification Of Malfunction And Abnormity & Measures

    Operating Instruction Manual for 3610-Series Angular Travel Electronic Actuator 7. Identification of malfunction and abnormity and measures Tabl e 7.1 Phenomenon of Cause analysis Troubleshooting malfunction ●Po wer is not connect ed ●Conne ct the pow er ●Li ne broken or ter mi nal is ●Repl ace the po wer li ne and not connect ed wel l fas ten...
  • Page 24 KOSO CONTROL INSTRUMENT (ANSHAN) CO.,LTD. Address: Anshan Tiexi District No. 20 West Frontage Tel: 0412-8812686 8829528 Fax: 0412-5226389 Website: www.as-koso.com Postal code: 114016 January 18, 2020...

Table of Contents