T-Air Helmet ® Powered Air Purifying Face Shield (Helmet) User Instructions * Designed to be used with PAPR system www.rsgsafety.com...
Page 2
SAFETY WARNINGS - READ BEFORE USING WARNING Read & Understand All Instructions Before Using RSG T-air Helmet is intended to protect the wearer's head and respiratory system against ® injury caused by striking the head against hard, stationary objects, and to protect the eye and face from sparks, particle spatters, hot solid spatters, metal melts.
2. SYSTEM DESCRIPTION RSG powered air purifying helmet has a compact shape and a balanced center of gravity. Used together with PAPR system, the protection class is TH3 (see table). It is convenient, comfortable and easy to adjust, providing users with comprehensive protection for respiratory, eyes and face, head, and hearing (requires noise-cancelling earmuffs).
Page 4
PARTS LIST & ASSEMBLY ITEM PART NO. DESCRIPTION T-Air Helmet Headtop ® 660216 Headgear 660471 Forehead sweatband 660216 Head suspension 660203 Comfort back pad 660121 Standard face seal 660311 Headtop (Velcro version) 660301 Headtop buttons 660667 Visor frame assembly 660664 Visor frame buttons A-10 660729...
Page 5
3. INSTRUCTIONS FOR USE 3.1 Adjust Headgear • Put the face shield on and adjust the face seal, make sure the face seal fully sealed around the face (See fig.1a). • Adjust the back headgear knob until the face shield fixed on the head properly (See fig.1b). fig.1a fig.1b 3.2 Face Shield Height Adjustment...
Page 6
3.3 Air Flow Direction Adjustment • Toggle forehead air flow direction adjustment plate to adjust direction of the airflow in face shield to ensure comfortable wearing (2 gears adjustable) (See fig.4) fig.4 3.4 Connect Hose to Helmet • Pull the head of hose to connect it to protruding connector of T-Air Helmet, and then turn the ® bajonet coupling tothe head of hose to complete the fixing.
4. MAINTENANCE 4.1 Replacing Protective Visor To remove visor • Pull up the latches and remove buckles from both sides (See fig.6a / 6b), keep the parts appropriately. Push the central of visor top edge from internal side, until you hear a “click” to get out the visor (See fig.7a / 7b).
Page 8
4.2 Replacing Face Seal • Fix the edge groove of the face seal to the edge of the outside frame of the face shield (See fig.9a), and press to the arrow direction to complete the installation (See fig.9b), and hang the inner and outer elastic bands on both sides to the “T”...
Page 9
• Remove soft band from headgear and replace with a new webbing (See fig.11). fig.11 fig.12 4.4 Replacing Visor Frame Assembly • Push out the button from inside of the visor (See fig.13a), disassemble two buttons from both sides (See fig.13b), remove the visor frame assembly and replace the new one (See fig.13c). fig.13a fig.13b fig.13c...
5. CLEANING AND DISINFECTION 5.1 CLEANING • The helmet respirator should be cleaned after every use. Clean the face shield by wiping with a soft cloth. Clean the visor surfaces regularly. Do not use strong cleaning solutions. Clean it with methylated spirit and a clean cloth and wipe dry with a lint-free cloth.
6. TECHNICAL SPECIFICATIONS Model No. T-Air Helmet ® Viewing Area 426 cm (66 sq. in) Storing Temp. -10°C ~ 55°C Application Industry Painting / Metal processing / Other applications with hot particles Approval EN 12941:2023 ; EN 166:2001;EN 397:2012. APPROVED INSTITUTION Produktion controll according module D of the regulation 2016/425 : DEKRA Testing &...