  • Page 1 Issue 5.0 April 2016 MC200/V3 Control System Industrial & Commercial Heating Systems. w w w . p o w r m a t i c . c o . u k Users Instructions WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Reset from Lockout is by a switched Neutral GB &...
  • Page 2 & professional service and back-up you deserve. If you have any questions or concerns regarding this product, please contact our Technical Support Team by calling 01460 53535. Users Instructions CONTENTS Section Page Description Specification Keypad Layout User Controls Page 2 MC200/V3 Users Instructions Issue 5.0 April 2016...
  • Page 3: Specification

    Optimum start technology is available that will continually The MC200/V3 can give a readout of the hours the burner monitor the heating systems previous performance to has operated, to help accessing servicing intervals and...
  • Page 4: Optimum Stop

    When Optimum Start is enabled the - The MC200/V3 keeps a note of how many minutes are switch-on time for the heater is then advanced accord- taken for the temperature to drop the number of degrees...
  • Page 5: User Controls

    BST-GMT changeovers, carries out the holiday To return to the normal display press X or do not touch any shutdown function and permits override password entry. keys for 15 or more seconds. MC200/V3 Users Instructions Issue 5.0 April 2016 Page 5...
  • Page 6 OFF, the heater will not operate under new service date when the heating equipment has been serviced. frost conditions in any User mode. OFF - the heater never operates unless the tempera- Page 6 MC200/V3 Users Instructions Issue 5.0 April 2016...
  • Page 7 VALID or FAIL. If FAIL displays check password and repeat entry  < - + > sequence. The User password, if set, must be entered for access to User functions. Next MC200/V3 Users Instructions Issue 5.0 April 2016 Page 7...
  • Page 8 Every effort is made to ensure accuracy at time of going to press. However as part of our policy of continued product improvement, we reserve the right to alter specification without prior notice. Page 8 MC200/V3 Users Instructions Issue 5.0 April 2016...