Cold Point Adirondack Aire WC Series Installation, Operation & Maintenance Manual

Cold Point Adirondack Aire WC Series Installation, Operation & Maintenance Manual

Water cooled console air conditioner replacement unit

Advertisement

WC series
Water Cooled Console Air Conditioner Replacement Unit
INSTALLATION, OPERATION
INSTALLATION, OPERATION
& MAINTENANCE MANUAL
& MAINTENANCE MANUAL
Cold Point Corporation, Rome, New York 13440 | Phone 315.339.2331 Fax 315.339.2358 | www.ColdPointCorp.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Adirondack Aire WC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Cold Point Adirondack Aire WC Series

  • Page 1 WC series Water Cooled Console Air Conditioner Replacement Unit INSTALLATION, OPERATION INSTALLATION, OPERATION & MAINTENANCE MANUAL & MAINTENANCE MANUAL Cold Point Corporation, Rome, New York 13440 | Phone 315.339.2331 Fax 315.339.2358 | www.ColdPointCorp.com...
  • Page 2 Only auxiliary electric heaters approved by Cold Point shall be Only auxiliary electric heaters approved by Cold Point shall be who meet local, state, and federal proficiency requirements.
  • Page 3 Adirondack Aire WC series - IOM Attentions, Cautions, and Warnings CAUTION CAUTION CAUTION CAUTION DO NOT store or install units in corrosive environments or in DO NOT store or install units in corrosive environments or in For duct connected appliances containing A2L refrigerants, false For duct connected appliances containing A2L refrigerants, false locations subject to temperature or humidity extremes (e.g., attics,...
  • Page 4: General Information

    Adirondack Aire WC series - IOM General Information Inspection: Preparation of Units for Installation: Upon receiving your equipment, carefully check the 1. Verify Unit Shipment: Confirm that the electrical shipment against the bill of lading. Make sure you specifications on the unit’s nameplate match the have received all units.
  • Page 5 Adirondack Aire WC series - IOM General Information intrinsically safe. • Refrigerant piping or components are installed in Presence of Fire Extinguisher: a position where they are unlikely to be exposed In the event that hot work is to be performed on...
  • Page 6: Refrigerant System

    Adirondack Aire WC series - IOM General Information Repair to intrinsically safe components: Table 1: Altitude Adjustment Intrinsically safe components must be replaced. ft (m) Cabling: 0 (0) 1.00 Ensure that the cabling is protected from wear, 656 (200) 1.00...
  • Page 7: Refrigeration System

    Adirondack Aire WC series - IOM Refrigerant System Servicing to avoid using compressed air or oxygen for purging The following leak detection methods are acceptable refrigerant systems. for all refrigerant systems: For appliances with flammable refrigerants, the Electronic leak detectors can be employed to purging process involves breaking the vacuum with locate refrigerant leaks;...
  • Page 8 Adirondack Aire WC series - IOM Refrigerant System Servicing special cylinders for the recovery of refrigerant). • All personal protective equipment is accessible Cylinders shall be complete with pressure-relief and utilized properly. valve and associated shut-off valves in good working order.
  • Page 9: Operating Limits

    Adirondack Aire WC series - IOM OPERATING LIMITS Minimum Cold Cooling Heating Model serviceable Start area (ft2) Min. Ambient Air WC-06 12.7 Min. EWT Min. EWT WC-09 13.0 Max. Ambient Air 95/78 WC-12 17.7 Max. EWT WC-16 20.2 Normal = 3.0 Max = 4.2...
  • Page 10 Adirondack Aire WC series - IOM Installer - General Information 3). Disconnect the power supply at the chassis We have designed and manufactured this unit to be junction box or unplug the line cord. safe and trouble free. As the installer of this unit, you play a major role in assuring it’s intended performance...
  • Page 11 Adirondack Aire WC series - IOM alloy rated to withstand the pressure and temperature Rated typically found in commercial heating systems. High Voltage Volts Volts temperature braze is recommended. Separate the union halves for brazing to the existing water lines/ headers.
  • Page 12 Adirondack Aire WC series - IOM 8). Locate the thermostat label on the front of the • Is the wiring properly sized and run in according with heat coil cover panel. Carefully route the thermostat- the unit wiring diagram? sensing bulb down under the heating coil and into the clamps adjacent to the label.
  • Page 13 Adirondack Aire WC series - IOM 4). For energy conservation reasons you may want months, and replaced or cleaned when dirty. Unit to set your thermostat at a higher temperature when operation becomes very inefficient with dirty filters. you are away. Do not raise the temperature setting Unit warranty is void if filters are not maintained by more than 5 degrees.
  • Page 14 Adirondack Aire WC series - IOM and dirt load. The following is the suggested method of cleaning coils: 1). Disconnect all electrical power to the unit. 2). Wear the appropriate personal protective equipment. 3). Gain access to the coil section of the unit (both sides).
  • Page 15 Adirondack Aire WC series - IOM Before Calling for Factory Assistance A call to the factory is sometimes necessary for technical support or service/troubleshooting. We are happy to help! Before calling please gather and record the following information so that we are best able to help.
  • Page 16: Troubleshooting Chart

    Adirondack Aire WC series - IOM TROUBLESHOOTING CHART The troubleshooting chart that follows is provided to serve as an aid for identifying malfunctions that may occur. Within the chart are three columns. 1. The Problems column describes what the unit is doing.