Page 1
F Monitor Essential Installation, Operation and Maintenance Manual...
Page 2
No part of this document may be made public or shared without the express permission of Absolent Air Care Group AB. Filtermist Limited, part of Absolent Air Care Group AB, are based at Telford 54 Business Park, Nedge Hill, Telford, Shropshire, TF3 3AL.
Page 3
Table of Contents 1. Introduction ..................4 1.1. Parts List ................4 2. Installation Guide ................5 3. Troubleshooting ................12 4. EU Declaration of Conformity ............15...
Page 4
Introduction 1. Introduction Welcome to the installation and maintenance manual for your F Monitor Essential. The F Monitor Essential is a monitoring device that measures airflow to indicate when your unit needs servicing, or if there are any blockages in the extraction system which may be affecting performance.
Page 5
Installation Guide 2. Installation Guide Step 1. Two strong magnets enable you to mount the monitor. Step 2. Alternatively fix two screws at 60mm centres to a flat vertical surface and hook the monitor onto the screws. 3.5mm max diameter on the thread, 8.5mm max diameter head.
Page 6
Installation Guide Step 3. Power to the F Monitor Essential is supplied from two AA batteries (not inclu- ded); these should be replaced when the battery light indicates. Fit the batteries as per the instructions on the circuit board. Step 4. Both airflow and battery lights will flash twice when starting. After this, a continu- ous blue flash from the airflow light will occur.
Page 7
Installation Guide Step 5. To connect the F Monitor Essential to the unit, you first need to prepare the unit: fit the black nozzle into the hole in the diaphragm. Step 6. Mark both ends of one of the hoses with a pen.
Page 8
Installation Guide Step 7. To prepare the pressure sensing hoses, feed the two hoses through the conduit. Step 8. Connect the hose marked with pen to the nozzle on the diaphragm. Then connect to the left hand nozzle on the bottom of the monitor.
Page 9
Installation Guide Step 9. Connect the other hose to the motor using the motor clip with the hose pointing up. Then fix to the right hand nozzle on the bottom of the monitor. IMPORTANT! Ensure the hoses are not pinched or trapped as this will affect the function of the F Monitor.
Page 10
Installation Guide Step 11. After all parts are fitted, you need to calibrate the monitor. To do this, firstly turn on the filter unit, making sure it is running normally and in the correct direction. Follow the red arrow on the filter unit to check this. Step 12.
Page 11
Installation Guide Step 13. When the hoses are connected and the unit is turned on and rotating in the correct direction, press the calibrate button on the circuit board. The monitor will calibrate for the first 10 seconds, and a solid green light will stay on for two minutes as the airflow is dynamically sensed (if a blue light is flashing, the hoses may have been connected the wrong way round).
Page 12
Troubleshooting 3. Troubleshooting When on RED light check for a blockage before calling for a service. Follow the proce- dures below. Step 1. Remove hoses from the sensor and blow compressed air down the hose towards the nozzle, not towards the monitor.
Page 13
Troubleshooting Step 2. Make sure the wire mesh has no blockages. Step 3. Make sure the ducting has no blockages.
Page 14
Troubleshooting Step 4. Make sure the afterfilter is not blocked by removing it from the filter unit and checking. If a blue light is flashing, this means the monitor is uncalibrated. If you have attempted to calibrate, then it did not recognise the airflow. You will need to recalibrate.
Page 15
EU Declaration of Conformity 4. EU Declaration of Conformity EU Declaration of Conformity Company Name: Filtermist Limited Postal address: Telford 54 Business Park, Nedge Hill City: Telford Postcode: TF3 3AL Telephone Number: 01952 290500 E-mail address: sales@filtermist.com Declare that this DOC is issued under the sold responsibility of the manufacturer. Product: F Monitor Essential, F Monitor 2 and 2+ Type: N/A Batch: N/A...