SOCKET USB POWER SUPPLY
Installation manual
Safety instructions
Before installing the unit, read this manual thoroughly and retain it for future reference.
The device should be installed in compliance with official regulations valid in country of use.
The device may only be installed and connected by qualified electricians.
Ensure that electricity is switched off when installing or unmounting the device.
Do not open, dismantle, alter or modify the device.
Components
USB power supply
0402-03:
2 x USB-A power supply black
0402-13: USB-A + USB-C power supply black
0402-23: 2 x USB-C power supply black
A
B
B
B
B
A
A Opening to fix the outlet to the wall box
B Clips to mount the cover plate
C Alignment guides for 2-gang and 3-gang installations
Wall boxes
The sockets should be installed in European wall boxes with screws.
The distance between the screws needs to be 60 mm, and a minimal depth
of 45 mm is required.
Square wall boxes size 60 x 60 mm are compatible with the sockets.
Round wall boxes should have an inner diameter of 64 mm or more.
For multigang sockets, make sure the wall boxes are aligned perfectly horizontal with a
centre-to-centre distance of 71 mm. Preferably use a multigang wall box.
The following round wall boxes are compatible with the Basalte sockets :
•
Helia round with cut hole Ø 68 mm (type 247, 261).
•
Kaiser round with cut hole Ø 68 mm (type 9063-xx, 9064-xx, 9062-xx).
•
Legrand batibox round (type 080051, 080061, 080052, 080053).
•
ABB round Hafobox MD4050 and hollow wall boxes HW-50,
HW50-G, HW52-F (except HW52-F IGD and HW52-F BW).
When using other round boxes, please verify the
compatibility upfront.
Do not use following wall boxes:
•
Helia O-range
•
Kaiser (1055-xx, 1056-xx)
•
ABB 3040
•
ABB HW52-F IGD and HW52-F BW
C
C
0402-03
USB power cover
(not included)
Model No. 0412-xx
Model No. 0422-xx
0402-13
Model No. 0432-xx
0402-23
Need help?
Do you have a question about the 0402-03 and is the answer not in the manual?
Questions and answers