Page 2
Softener Specifications................Page 3 Softener Installation.................. Page 4 Control Valve Start Up Procedure............. Page 10 Programming the Control Valve............Page 11 Master Programming................Page 13 Utilizing Bluetooth..................Page 14 Control Valve Powerhead Assy. Sig 3..........Page 17 Valve Body Assembly Sig. 3..............Page 18 Bypass Assembly Sig.
Page 3
Specifications General Specifications MN15-S3 MN25-S3 Grains Capacity / Regeneration 15,000 25,000 Salt Used / Regeneration 18.0 30.0 Maximum Raw Water Nitrate / Sulfate (mg/l) Maximum Clear Iron / Manganese (ppm) Exchange Resin (cu ft) Mineral Tank Size 10 x 54 13 x 54 Brine Tank (polyethylene with grid &...
Page 4
Installation Note: Due to the Nitrate System abilities to remove bi-carbonate (alkalinity) from the water, a dramatic reduction in pH of the treated water may be experienced. If this occurs, a whole house or upflow filter with neutralizer or Neu-Cor media may be required. Installation Requirements •...
Page 5
Installation Installation Procedure Water Supply Connections and Bypass Valve To allow for filter servicing, swimming pool filling or lawn sprinkling, a manual bypass valve has been installed at the factory. The bypass allows water to be manually routed around the filter. 1.
Page 6
Installation -Brine Line and Overflow Connection- Note: Your brine tank comes with two brine lines. Black is for outdoor installation. Opaque is for indoor installation. Feed one end of brine line to brine line connection on Inside the brine tank, remove the cap from the top of the brine well.
Page 7
Installation How To Calculate Regeneration Frequency Note: The quantity of both nitrate and sulfate must be known for proper regeneration calculation. Step 1: Convert Nitrate (NO3) and Sulfate (SO4) to Calcium Carbonate (CaCO3). Nitrate Divide ppm (mg/l) of Nitrate by 62 and multiply by 50.1 Example : (50 ppm NO3/62) x 50.1 = 40.4 ppm as CaCO3...
Page 8
Installation Step 4: Calculate the grains capacity for the system being installed. Example : MN15 = 1.5 cu. ft. x 8,500 grains / cu. ft. = 12,750 total grains capacity Step 5: Calculate total grains of nitrate. ppm as CaCO = grains of Nitrate 17.1 Example:...
Page 9
Installation Filling The Brine Tank With Salt To expect a high level of performance and reliability, a salt manufactured specifically for water softeners must be used. Salt of this grade is virtually free from dirt and other particulate that would eventually cause the nitrate filter to malfunction.
Page 10
Control Start-Up Procedure Put unit in bypass using the handles behind the control valve. Start a regeneration by pressing and holding the set change button for 3 seconds. The display may show zeros or a 1, repeat holding the set change button. Display on unit should read 1-10 (Step 1-10 min).
Page 11
Programming the Control Valve - Programming The Control Valve - 1. Set time of day. 2. Set a.m. or p.m. 3. Set water hardness in grains per gallon (gpg). Note: If the water contains iron and / or manganese, multiply the total parts per million (ppm) by “four” (4) and then add to the grains per gallon (gpg) of hardness.
Page 12
Programming the Control Valve Normal Operation 1. Home Display Metered models alternate the Time of Day and Gallons left until the next regeneration. The meter will count down to zero (0000) and then regenerate at the scheduled time set. 2. Battery Back-Up (Uses a standard 9-volt alkaline battery.) Features of Battery Back-Up: •...
Page 13
Master Programming Mode Master Programming Mode To enter Master Programming Mode, press and hold both buttons for 5 seconds. Note: All Master Programming functions have been preset at the factory. Unless a change is desired, it is NOT necessary to enter Master Programming Mode. 1.
Page 14
Utilizing Bluetooth Control For simplified set up and control, please install the Legacy View on a compatible Bluetooth 4.0+ enabled smart phone or tablet. 1. Download and install the Legacy View app from the Google Play Store, Apple App Store 2.
Page 15
Set Up Utilizing Bluetooth App Change Time of Day (Press “SET” to set time automatically based on device). For Filters: Set Backwash Frequency This sets the amount of day between backwash cycles Set Regeneration Time Example: For 2a.m., just type 2, choose a.m., and press ‘OK’ Note: If you have a filter and a softener the valves should be set to regenerate at different times.
Page 16
Set Up Utilizing Bluetooth App Status and History From the Status and History, all items in ORANGE can be reset. Pressing this icon will show a list of the data that is in the graph. Touch any graph to enlarge and see details.
Page 17
- SIGNATURE 3 Powerhead Assembly LETTERS IN DIAGRAM REPRESENT WIRING CONNECTIONS DESCRIPTION PART NO. Metered Power Head Assy. 21003X100 Softener Circuit Boad Assy. 22003X102 Encoder 20001X124 Front Plate 20001X004 Encoder Wheel 20001X007 Main Gear 21001X120 Power Supply 20001X125 Back Plate 20001X005 Lower Front Base For Cover 20111X002...
Page 19
- Signature 3 Valve Body Assembly DESCRIPTION PART NO. Piston Assembly 20001X231 10-24 X 3/4” Screw SST 20001X001 Seal and Spacer Kit 20561X253 End Spacer 20001X234 Flow Control Button 1.5 GPM 20251X266 Flow Control Button 2.0 GPM 20251X267 Flow Control Button 2.4 GPM 20251X268 DLFC Assy.
Page 20
- Signature 3 Bypass Assembly DESCRIPTION PART NO. D15 Bypass (included with all units) 20017X283 1” NPT Elbow Set (included with all units) 20017X284 1” Female Straight Slip Set (optional) 20017X288 1” NPT Straight Set (optional) 20017X289 3/4” NPT Straight Set (optional) 20017X307 1”...
Page 21
Service Instructions / Instructional Videos Available at www.csiwater.com General Preliminary Instructions PERFORM BEFORE ALL SERVICING OPERATIONS 1. Turn off water supply to conditioner. -If the conditioner installation has a “three valve” bypass system, first open the valve in the bypass line, then close the valves at the conditioner inlet and outlet.
Page 22
Service Instructions / Instructional Videos Available at www.csiwater.com To Service Injector and Screen 1. Follow steps A1-A2. 2. Unscrew injector cover screws and remove injector cover. 3. Remove injector screen and clean or replace. 4. Remove injector and clean or replace. 5.
Page 23
Troubleshooting Guide SYMPTOM PROBABLE CAUSE CORRECTION Power supply plugged into Connect to constant power source intermittentent or dead power source 1. Softener Fails to Disconnected meter cable Reconnect cable Regenerate Improper control valve Reset program settings Automatically programming Defective power supply Replace power supply Meter is dirty or defective Clean or replace meter assembly...
Page 24
Troubleshooting Guide SYMPTOM PROBABLE CAUSE CORRECTION Plugged drain line or drain line control Check flow to drain. Clean drainline flow control button 7. Excessive Water in Dirty or damaged brine valve Clean or replace brine valve. Brine Tank and / or Plugged injector or screen Clean or replace injector screen.
Page 25
Error Codes Control Valve Error Code Diagnosis Under normal operating conditions, when your control valve is in the “in service” position, the display should alter- nate between the current time of day and the number of days remaining (for filters and time clock softeners) or gal- lons remaining (for metered softeners) until the next regeneration.
Page 26
Residential Reverse Osmosis System 5 Years the price paid for the product. In no case shall CSI or seller be liable for any special, incidental, contingent or consequential damages. Special, Other Accessoreis and Parts...
Page 28
CSI WATER TREATMENT SYSTEMS 710 Orange St, Ashland, OH 44805 l PH 419-281-6829 l FAX 419-281-2375 www.csiwater.com 1024TV...
Need help?
Do you have a question about the Signature 3 MN15-S3 and is the answer not in the manual?