Download Print this page

Advertisement

Quick Links

Preface ...................................................................................................................... 0-1
Chapter 1 safety instructions .................................................................................. 1-1
1.1 Before Power On ..................................................................................... 1-1
1.2 After Power On ............................................................................................. 1-1
1.3 Wiring ........................................................................................................... 1-2
1.4 Before running .............................................................................................. 1-2
1.5 Parameter setting .................................................................................... 1-2
1.6 Revolve ........................................................................................................ 1-3
1.7 Inspection, maintenance and replacement ................................................... 1-4
Chapter 2 model description ................................................................................... 2-1
2.1 Inverter nameplate ....................................................................................... 2-1
2.2 type code description ................................................................................... 2-1
Chapter 3 ambient environment and installation .................................................. 3-1
3.1 Environment ................................................................................................. 3-1
3.1.1 Operating environment ........................................................................ 3-1
3.1.2 Installation position .............................................................................. 3-1
3.2 Appearance .................................................................................................. 3-2
3.2.1 Size and installation hole position .............................................................. 3-3
3.2.1.1 Scope of application:110KW-250KW ................................................. 3-2
3.2.1.2 Scope of application:280KW-355KW ................................................. 3-3
3.2.1.3 Scope of application:400KW-760KW ................................................. 3-4
3.2.2 Peripheral equipment wiring ...................................................................... 3-5
Chapter 4 electrical wiring ....................................................................................... 4-1
4.1 Electric diagram of frequency converter cabinet .......................................... 4-1
4.2 Terminal function description ....................................................................... 4-3
4.2.1 Main loop terminal description ............................................................. 4-3
4.4.2 Control wiring diagram of variable frequency cabinet .......................... 4-3
Chapter 5 software indices ...................................................................................... 5-1
5.1 There are two parameters setting ................................................................ 5-1
5.1.1 OP_INV User monitoring parameters group description .................... 5-1
5.1.2 OP_INV Programming parameter group description ......................... 5-2
5.1.3 OP_SPG Programming parameter group description ........................ 5-3
Chapter 6 exception diagnosis and troubleshooting ............................................ 6-1
6.1
......................................................................................................... 6-1
General
6.1.1 OP_INV Fault message and exclusion Description ............................ 6-1
6.1.2
OP_SPG Fault message and exclusion Description
6.1.3 Other faults message and exclusion Description ............................... 6-6
Directory
I
................................. 6-5

Advertisement

loading
Need help?

Need help?

Do you have a question about the YD1 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Yolico YD1 Series

  • Page 1 Directory Preface ........................0-1 Chapter 1 safety instructions .................. 1-1 1.1 Before Power On ..................1-1 1.2 After Power On ..................... 1-1 1.3 Wiring ......................1-2 1.4 Before running ....................1-2 1.5 Parameter setting ..................1-2 1.6 Revolve ......................1-3 1.7 Inspection, maintenance and replacement ...........
  • Page 2 Chapter 0 preface 0.1 preface In order to fully play the function of the frequency conversion cabinet and ensure the safety of users, please read this operation manual. When you find difficult problems in the use process, please contact the dealer or technical staff of our company, our professional staff will be willing to serve you。...
  • Page 3 Chapter 1 Safety precautions 1.1 Before Power On Warning  The main loop terminal must be correctly matched,3-phase(R、S、T)is power input terminal, Never mix with the motor output terminals ( u, v, w ); When mixing, the power supply will cause damage to the inverter cabinet. Attention ...
  • Page 4 Attention  If the product needs parameter modification, please pay attention to the danger of injury in the motor rotation. Otherwise it may cause an accident.。  Do not touch the heat sink。 1.3 Wiring Warry  Before implementing any frequency conversion cabinet installed or wiring, please be sure to turn off the total power supply and avoid electric shock and fire。...
  • Page 5  Do not connect the input power to the inverter output terminal。  Do not connect the electromagnetic contactor, electromagnetic switch contact to the output terminal。  Do not connect the phase capacitor or LC / RC filter to the output circuit。 ...
  • Page 6 1.6 Revolve Warning  Please confirm that the front door closes and turn the knob to the closed position, and then turn on the power supply.  In the operation, the motor unit can not be put into or cut off, otherwise it is easy to cause the frequency conversion cabinet over-current trip, serious time will cause the main circuit damage of the converter.
  • Page 7 1.7 Inspection, maintenance and replacement Warning  Before performing maintenance check, verify that the power supply is off and the power led is off ( please confirm that the DC voltage is not more than 25 volts )  There are high voltage terminals in the terminal of frequency conversion cabinet, do not touch freely.
  • Page 8 Chapter 2 Description Model Number 2.1 Inverter nameplate 2.2 type code description -LSPG ① ② ③ ④ ⑤ ⑥ ⑦ Grade Rules explain ① Series name ② Rated power of suitable motor 132kW ③ Input voltage T4:380V T6:660V ④ Allow maximum start current LSPG:The starting current is maximum within 50 % of the rated current HSPG:The starting current is maximum...
  • Page 9 Chapter 3 ambient environment and installation 3.1 Environment 3.1.1 Operating environment The environment of frequency conversion cabinet installation has direct influence on the normal function of frequency conversion cabinet and its service life, so the installation environment of frequency conversion cabinet must meet the following conditions: Protection IP Level IP20...
  • Page 10 3.2 Appearance 3.2.1 Size and installation hole position 3.2.1.1 Scope of application:110KW-250KW...
  • Page 11 3.2.1.2 Scope of application:280KW-355KW...
  • Page 12 3.2.1.3 Scope of application:400KW-760KW...
  • Page 13 3.2.2 Peripheral equipment wiring and matters needing attention of frequency conversion cabinet Be sure to confirm the warning message of the front outer cover of the frequency conversion cabinet,Refer to the following figure 3.3。 Fig 3.3 Warning label Attention Within 15 minutes of the input power supply, the main circuit may still have high voltage, and confirm that the DC bus voltage is lower than 36v before operation 2.
  • Page 14 not possible to test the pressure test of the internal components of the inverter cabinet。 6. The CMOS IC of the inverter cabinet control board is vulnerable to electrostatic influence and destruction, do not touch the control substrate。 Note: the main power switch points to " off" position in the factory. do not transfer the main power switch to "...
  • Page 15 Chapter 4 Description of electrical wiring 4.1 Electric diagram of frequency converter cabinet...
  • Page 16 Note 1. For wiring, refer to the table, select the appropriate wire wire diameter, when the main circuit wiring is long, the voltage drop should not be considered more than 2 % of the rated voltage。 Phase voltage drop △ v = × power line resistance ( Ω / km ) × distribution distance ( m ) ×...
  • Page 17 4.2 Terminal function description 4.2.1 Main loop terminal description PIN codes Connection object Matters needing attention Ac power supply 380-420 VAC +10%~-10% The between impedance of the motor needs to be balanced and Load motor there is no short circuit phenomenon The motor line and the earth PE impedance need an open circuit Ac power supply...
  • Page 18 Chapter 5 software indices 5.1 There are two parameters setting。 There are 2 debug display panels on the device, with different functions. The following description:: When we face the machine, the left panel, to start the special panel, function as the motor in stop, the inverter drag the motor。...
  • Page 19 5.1.2 OP_INV Programming parameter group description OP_INV Programming parameter group Group Para Name Setting Range Unit Explain B1-02 Operating instruction No adjustment ---- source C1-01 Acceleration time 20.0 0.1-3600.0 C1-02 Deceleration time 20.0 0.1-3600.0 ★ D1-13 Step 1 frequency 0.00-650.00 Note★...
  • Page 20 5.1.3 OP_SPG Programming parameter group description OP_SPG Programming parameter group item Para Explain Setting Range Unit Reamak C1-01 Switching angle up limit 0.1-3600.0 Note★★★ 20.0 C1-02 Switching angle lower 0.1-3600.0 Note★★★ 20.0 limits C1-03 Switching delay time 0.0-100.0 Note★★★ ★★★ Switching angle and time: according to different power and operating conditions have different settings.
  • Page 21 Chapter 6 diagnosis and elimination of anomalies 6.1 General Fault detection and early warning / self - diagnosis function of frequency conversion cabinet. When the frequency conversion cabinet detects that the fault code is displayed in the led operator, the fault contact output action, cut off the output of the inverter cabinet, so that the motor is free to run ( in some fault, the method of stopping is optional )。...
  • Page 22 2.L8 - 05 = 1, start this fault lightning protection 3. seeking technical support detection. board 3. abnormality of the main control board 1. the lead of the 1. troubleshooting peripheral converter to the faults motor is not normal 2. check whether the Output due phase: The output of the converter 2.
  • Page 23 contactor is not input, and 3. the acceleration time the converter is running. setting is too short. 4. check the power system Approx. 380 VDC capacity. ( the detection value can 4. the voltage be adjusted by l5 - 09 ). fluctuation of the 5.
  • Page 24 attribute in not debugging original customer service Non - professionals Check the manual or notify the OPE15 Parameter setting error debugging original customer service 1. attempt to modify O2 - 04 2. the change of parameter value in communication is Overrun STP0 Zero speed stop...
  • Page 25 The following malfunctions may be encountered during the spg power frequency switching process, please refer to the following methods for simple fault analysis 6.1.2 OP_SPG Fault message and exclusion Description OP_SPG Fault message and exclusion Item Fault Description Possible causes Exclude Display 1.
  • Page 26 6.1.3 Other faults message and exclusion Description Other faults Failure Item Possible causes Solution phenomenon 1. power grid voltage is not or too low 2. the switch power supply fault of the inverter drive plate 1. check the input power supply No display on 3.