Summit SML-48BR-VEN Installation And Operation Manual

Summit SML-48BR-VEN Installation And Operation Manual

Linear luxury fireplace

Advertisement

Quick Links

Summit Linear Luxury Fireplace
INSTALLATION AND OPERATION MANUAL
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home,
where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings
exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
WEBSITE
Certified to the Canadian and American National Standards: CSA 2.22.2019 and ANSI Z21.50.2019 for decorative gas appliances for installation in solid-Fuel burning fireplaces.
3515 East Atlanta Avenue, Phoenix, Arizona 85040 | 602-344-4217 | grandcanyongaslogs.com
• Do not touch any electrical switch; do not use any phone in
your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Report # F24-308
FOR INDOOR OR OUTDOOR PATIO USE
Grand Canyon Gas Logs
07-00146 | 072024_V1

Advertisement

loading
Need help?

Need help?

Do you have a question about the SML-48BR-VEN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Summit SML-48BR-VEN

  • Page 1 Summit Linear Luxury Fireplace INSTALLATION AND OPERATION MANUAL This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
  • Page 2 Installation Steps ..............30-32 Log Placement ................ 33-38 Operating Instructions ............39-44 Troubleshooting ..............45-46 Warranty ..................47 Notes ..................... 48 NOTE: Changes, other than editorial, are denoted by a vertical line in the margin. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 3 For more information go to www. toddlers, young children, and other at-risk individuals out of P65Warnings.ca.gov and away from hot surfaces. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 4 Follow the gas supplier's instructions • If you cannot reach you gas supplier, call the fire department. 20. Provide adequate clearances around air openings. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 5 INTRODUCTION INTRODUCTION CAUTION Do not remove data plates from module. Thank you for the purchase of Grand Canyon Gas Logs, Summit Linear Data plates contain important warranty and safety Luxury Fireplace. All models use an electronic control valve and information.
  • Page 6 Internal wall installations provide a discreet option for room separation and can also be ideal as an addition to an existing wall. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 7 GENERAL INFORMATION SERIAL LABEL SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 8 40000 SML-60BR-VEN 75000 50000 SML-72BR-VEN 90000 60000 LIQUID PROPANE MODELS Rated Rated Rated Rated Rated Manifold Inlet Inlet LP Models High Pressure SML-48BR-VEP 60000 30000 SML-60BR-VEP 75000 40000 SML-72BR-VEP 90000 50000 SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 9 85000 40000 SML-72BRT-VEP 85000 40000 LOG IDENTIFICATION LDBT-DW48 Bedrock Traditional 48" Western Driftwood logs LDBT-DW60 Bedrock Traditional 60" Western Driftwood logs LDBT-DW72 Bedrock Traditional 72" Western Driftwood logs *BRT models ONLY SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 10 SUMMIT LINEAR-PARTS LIST SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 11 OPTIONAL VIEWING REDUCTION KIT SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 12 INTERIOR PANEL KITS SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 13 PARTS LIST-BEDROCK CONTEMPORARY MODELS *Glass media NOT INCLUDED, refer to installation instructions (page 31, Step 10) (page 31, Step 10) for glass usage. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 14 PARTS LIST-BEDROCK TRADITIONAL MODELS SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 15 LOG #5 Burner Log 05-00187 LOG #13 Static Log 05-00180 LOG #6 Burner Log 05-00188 LOG #14 Static Log 05-00181 LOG #7 Burner Log 05-00189 LOG #15 Static Log 05-00182 LOG #8 Static Log SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 16 WIRING DIAGRAM System Configuration: SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 17 2. Remove both screws holing in the thermostat. 3. Press the button located between the terminals on the back of the thermostat. 4. Reinstall thermostat using the same screws. Spill Switch Reset Button SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 18 PHYSICAL DIMENSIONS SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 19 SUMMIT FIREPLACE CONFIGURATIONS Figure 9 - Fireplace Configurations SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 20 4. Check level of the fireplace and shim with sheet metal if necessary. 5. Using screws or nails, secure fireplace to framing through flanges located on sides of fireplace. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 21 FRAMING LEFT CORNER DIMENSIONS SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 22 FRAMING RIGHT CORNER DIMENSIONS SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 23 FRAMING BAY DIMENSIONS SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 24 CORNER INSTALLATION SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 25 Figure 15 - Finishing Material - Side View Figure 16 - Finishing Material - Front View Figure 17 - Mantle Height-Depth Chart Figure 18 - Mantle Heights SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 26 Locate the slot in the center section of the handle arm. Once slot has been pulled down to the key-way, push handle towards back of fireplace to lock handle in damper plate closed position. Figure 20. Figure 21 - Handle Position SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 27 VENTING INSTALLATION ALL Summit Linear Fireplaces are designed and equipped to use 12” B-Type venting systems. B-Venting systems can be used with high wind or standard termination caps and can be purchased through any 3rd party venting manufacturer. The 12” B-Type venting MUST be connected to the appliance and vented to the outside of the building.
  • Page 28 Install external regulator with the vent pointing down as shown in Figure 25. Figure 26 - Sediment Trap Pointing the vent down protects it from freezing rain or sleet. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 29 Liquefied Petroleum (LP or propane) and should be applied lightly to ensure excess sealant does not enter the gas line. Figure 28 - Connecting Incoming Gas Line to Flex Gas Line SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 30 OUT pressures) are provided on the gas control valve for test gauge connections to the appliance. Figure 30 - Checking Gas Joints for Propane/LP Gas Fireplace (Fireplace picture may vary from actual) SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 31 Figure 32 - Checking for Spillage noncombustible materials may overlap front face provided they do not obstruct essential openings such as louvered slots. When overlapping with a noncombustible facing material, use only noncombustible mortar or adhesive. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 32 Make sure to secure your incoming power cord with the provided conduit clamps and connect the wire to the outlet using proper electrical connections and fittings. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 33 6. Install batteries into the receiver and ensure the remote in synced to the receiver. Refer to the remote operation section for greater detail. 7. Replace burner case &/or burn decking that was removed in #2. 8. Replace burner casing trim. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 34 You will feel the magnets stick to the back wall. Figure 33 - Rear Panel Installation Figure 35 - Side Panel Installation Figure 36 - Side Panel - Top View Figure 34 - Rear Panel - Top View SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 35 48" BURNER AND GLOWFIRE™ WESTERN DRIFTWOOD LOG PLACEMENT GUIDE 05-00176 05-00178 05-00176 05-00175 05-00175 05-00176 05-00176 05-00179 05-00178 05-00178 05-00175 05-00175 05-00177 05-00177 05-00176 05-00176 05-00188 05-00179 05-00179 05-00178 05-00183 05-00182 05-00178 SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 36 LOG PLACEMENT SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 37 05-00175 05-00175 05-00180 05-00180 05-00176 05-00176 05-00179 05-00181 05-00181 05-00178 05-00178 05-00177 05-00177 05-00175 05-00175 05-00180 05-00180 05-00176 05-00176 05-00179 05-00181 05-00181 05-00179 05-00178 05-00178 05-00182 05-00182 05-00183 05-00184 05-00186 05-00184 SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 38 LOG PLACEMENT SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 39 05-00177 05-00176 05-00176 05-00180 05-00180 05-00178 05-00175 05-00179 05-00178 05-00175 05-00179 05-00181 05-00181 05-00186 05-00183 05-00184 05-00182 05-00184 05-00182 05-00177 05-00176 05-00180 05-00178 05-00175 05-00179 05-00181 05-00187 05-00186 05-00183 05-00184 05-00182 SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 40 LOG PLACEMENT SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 41 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 42 °C or °F is visible to the right of the room temperature display. See Figure 7.4 and 7.5. Figure 7.1 Figure 7.4 Figure 7.2 Figure 7.5 SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 43 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS 7.6. Figure 7.8 Figure 7.9 7.7 through 7.10. Figure 7.10 Figure 7.7 SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 44 A/C If the lockout reoccurs, call your dealer. The causes of lockout power is restored. must be investigated under safe conditions by trained service personnel. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 45 Turn valve to off position. 5. Adequate time varies on, size of bedrock, duration of use, and outside temperatures. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 46 Wi-Fi APP MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS Download to your mobile device SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 47 Remote does not function 1. Batteries are not installed. 1. Replace batteries in battery pack and in hand held Battery power is low. remote. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 48 Problem for Down lighting not working: 1. Inspect down lighting connection to proflame 2 board 1. Both lights do not turn on. within the unit. 2. Only one light comes on 2. Replace the light assembly. SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 49 Batteries are not covered under this warranty. ODS pilot assemblies carry a (1) year warranty. SCAN QR CODE FOR WARRANTY FORM SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...
  • Page 50 NOTES SUMMIT LINEAR INSTALLATION & OPERATIONS MANUAL GRANDCANYONGASLOGS.COM - 07_2024...