Download Print this page
Furuno PR-851 Installation Manual
Furuno PR-851 Installation Manual

Furuno PR-851 Installation Manual

Ac-dc power supply unit

Advertisement

Quick Links

Installation Guide
AC-DC POWER SUPPLY UNIT
PR-851
Model
SAFETY INSTRUCTIONS ................................................................................................ i
SYSTEM CONFIGURATION ........................................................................................... ii
EQUIPMENT LISTS........................................................................................................ iii
1. MOUNTING................................................................................................................ 1
1.1 Mounting Considerations ......................................................................................................1
1.2 Mounting Procedure..............................................................................................................1
2. WIRING....................................................................................................................... 3
2.1 Crimp-on Lugs and Cables for Wiring...................................................................................3
2.2 Wiring....................................................................................................................................3
3. OPERATION............................................................................................................... 5
3.1 How to Operate the PR-851..................................................................................................5
3.2 Maintenance .........................................................................................................................5
APPX. 1 JIS CABLE GUIDE ....................................................................................AP-1
SPECIFICATIONS ..................................................................................................... SP-1
PACKING LIST(S) ....................................................................................................... A-1
OUTLINE DRAWING(S) .............................................................................................. D-1
www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

Advertisement

loading
Need help?

Need help?

Do you have a question about the PR-851 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Furuno PR-851

  • Page 1 1.2 Mounting Procedure......................1 2. WIRING........................3 2.1 Crimp-on Lugs and Cables for Wiring...................3 2.2 Wiring............................3 3. OPERATION....................... 5 3.1 How to Operate the PR-851....................5 3.2 Maintenance .........................5 APPX. 1 JIS CABLE GUIDE ..................AP-1 SPECIFICATIONS ..................... SP-1 PACKING LIST(S) ....................... A-1 OUTLINE DRAWING(S) ....................
  • Page 2 Warning label(s) is(are) attached to the unit. Do not remove the label(s). If a label is missing Use only the specified power or damaged, contact a FURUNO agent or cable. dealer about replacement. Fire or damage to the equipment...
  • Page 3 Gateway MOD-Z072-100+ MOD-Z072-050+ MOD-Z072-020+ AC-DC Power Connected Battery DPYC-10/16 Supply Unit DPYC-10/16 Equipment-1 Charger PR-851 With backup BC-6201 Up to 30 A* : Standard supply Connected DPYC-10/16 Equipment-2 : Optional or local supply DPYC-4 Less backup Up to 2.5 A* : Up to less than 31.25 A.
  • Page 4 EQUIPMENT LISTS Standard Supply Name Type Code No. Remarks AC-DC Power PR-851 Supply unit Optional Supply Name Type Code No. Remarks LAN Cable MOD-Z072-100+ 000-167-177-10 10 m, for RMS MOD-Z072-050+ 000-167-176-10 5 m, for RMS MOD-Z072-020+ 000-167-175-10 2 m, for RMS...
  • Page 5 Mounting Procedure 1.2.1 How to mount the PR-851 The mounting procedure is as follows: Note: This unit is intended for desktop mounting. Do not install by any other method.
  • Page 6 1. MOUNTING 1.2.2 How to attach the Splash-proof Cover (Option) This unit complies with the ingress-proof rating IP20. When IP22 compliance is required, install the optional splash-proof cover as shown in the procedure below. 1. Unfasten the five screws (M36) highlighted in the figure below. 2.
  • Page 7 WIRING Crimp-on Lugs and Cables for Wiring Use the cable and crimp-on lug combinations shown in the table below to connect the power supply unit. The cables shown are JIS standard cables. See the JIS Cable Guide at the back of this manual for equivalent cables.. Cable Crimp-on lugs DPYC-4...
  • Page 8 2. WIRING 2.2.2 Wiring procedure Follow the procedure below to wire the unit. 1. Unfasten the screws on the ter- minal cover, then remove the cover. The screws and cover are required, do not discard them. 2. Unfasten the bind- ing screws on the DPYC-4 LAN cable...
  • Page 9 OPERATION How to Operate the PR-851 Use the power switch to turn this unit on (see the figure below). Breaker Power Switch Enlarged view of LED AC (GREEN) DC (WHITE) FAN1 FAN2 LED (See section 3.1.1) 3.1.1 LED Indications After turning on the power switch, the LEDs light or flash as shown in the below table.
  • Page 10 The IP address is reset to 172.31.16.31 (fac- tory default). Factory setting switch 3. Connect the PC and PR-851 with a LAN cable (optional). 4. Open the PR-851 WebUI (see figure below) from the PC browser and reconfigure the IP address at [Settings]-[Network]. PR-851 xxxxxxx-xx.xx xxx.xx.xx.xx xxx.xx.xx.xx...
  • Page 11 EX: TTYCYSLA - 4 MPYC - 4 # of cores Designation type Designation type # of twisted pairs TTYCSLA-4 The following reference table lists gives the measurements of JIS cables commonly used with Furuno products: Cable Core Cable Core Diameter Type...
  • Page 12 FURUNO PR-851 SPECIFICATIONS OF AC/DC POWER SUPPLY UNIT PR-851 GENERAL Rated input voltage 100-240 VAC, 1 phase, 50-60 Hz and 24 VDC from backup battery Input current 8.5-3.7 A (30A output) Rated output voltage 24 VDC (±10%) Rated output current 30 A (DC OUT1), 2.5 A (DC OUT2), Total 31.25 A max.
  • Page 13 装備時の注意 ............................1 装備手順 ............................. 1 2 章 結線 ........................3 ケーブルと圧着端子 ........................... 3 端末処理と結線 ........................... 3 3 章 操作と保守 ......................5 PR-851 の操作 ............................ 5 PR-851 の保守とトラブルシューティング ..................5 仕 様 ........................SP-1 パッキングリスト ......................A-1 外寸図 .......................... D-1 www.furuno.com...
  • Page 14 安全にお使いいただくために [ 必ずお守りください ] お使いになる人や他の人への危害、財産への損害を未然に防止するため、以下のことを必ずお 守りください。表示内容を無視して誤った使い方をしたときに生じる危害や損害の程度を、本 書では次の表示で区分し、説明していますので十分に気をつけてください。 WARNING To avoid electrical shock, do not remove cover. No user-serviceable parts inside.
  • Page 15 システム構成 機器のカテゴリ PR-851 風雨からの防護形...
  • Page 16 構成表 標準構成 名称 型式 コード番号 数量 備考 PR-851 AC-DC 電源ユニット オプション構成 名称 型式 コード番号 数量 備考 MOD-Z072-100+ 000-167-177-10 LAN ケーブル 10m RMS 通信用 MOD-Z072-050+ 000-167-176-10 5m RMS 通信用 MOD-Z072-020+ 000-167-175-10 2m RMS 通信用 ACC3720-91 000-200-031-10 IP22 用(防滴カバー無し 防滴カバー の場合は IP20)...
  • Page 17 1 章 機器の装備 装備時の注意 装備を行う際は、巻末の外寸図を参照し、次の点に注意してください。 また、作業を行う際は、必ず配電盤の電源スイッチを切ってください。 • 水しぶきや雨水が、直接当たらない場所を選んでください。 • 本機は、ブリッジ等のアクセス制限エリアに装備してください。 • 本機の装備と結線 ( アース線を含む ) は、サービス技術者が行ってください。 • 装備時は、外寸図を参照して必要なサービス空間を確保してください。確保され ていない場合、メンテナンスを行うことができなくなります。 装備手順 1.2.1 PR-851 の装備手順 本機は、以下の装備で装備します。 注)本機は、卓上装備(据置装備)のみ可能です。 1. 外寸図を参照し、6 本のタッピンネジ(M620、現地手配)を取り付けるた めの下穴を固定位置に開けます。 2. 本機を固定位置に置き、ネジ穴を合わせます。 3. ネジをしっかりと締め、本機を固定します。...
  • Page 18 1 章 機器の装備 1.2.2 防滴カバーの取付け ( オプション ) 本機の防塵・防水性能は IP20 に対応しています。IP22 に対応が必要な場合は、オ プションの防滴カバー( ACC3720-91 )を以下の手順で取り付けます。 1. 本機のネジ(M3×6)5ヶ所を緩め、取り外します(下図参照) 。 2. 防滴カバーを取り付け、手順 1 で取り外したネジのネジ穴と合わせます (下図参照) 。 3. 手順 1 で取り外したネジを締め付け、防滴カバーを本機に固定します。...
  • Page 19 2 章 結線 ケーブルと圧着端子 結線は、下表の JIS ケーブルまたは同等のケーブル(現地手配)と圧着端子(現地 手配)を使用します。 ケーブル 圧着端子 DPYC-4 FV5.5-5(または同等品) DPYC-10 R8-5(または同等品) DPYC-16 R14-5(または同等品) MPYC-2 FV1.25-4(または同等品) IV-5.5SQ(アース線) FV5.5-5(または同等品) 端末処理と結線 2.2.1 端末処理 端末処理は、下図を参照してください。...
  • Page 20 2 章 結線 2.2.2 結線 結線は、以下の手順で行います。 1. 端子台カバーのネ ジ 2 本を緩め、端 子台カバーを押し 上げて取り外しま す。 2. 端子台のバインド セムスネジを緩め て取り外し、以下 のケーブルを接続 します。 • DPYC-4(船内電源からのケーブル) • DPYC-10/16(バッテリーからのケーブル) 注)船内電源からのケーブルは、床に固定してください。 3. LAN ケーブル(MOD-Z072、オプション)を接続します。 4. LAN ケーブルを結束バンド(現地手配)で本機のケーブルクランプに固定 します(下図参照) 。 注)LAN ケーブルと他のケーブルを束ねて固定しないでください。無線機類に ノイズが発生する可能性があります。 5. 現地手配のアース線( )で、AC IN 端子台の FG 端子 IV-5.5SQ、または同等品...
  • Page 21 3 章 操作と保守 PR-851 の操作 本機を使用するときは、電源スイッチをオンにします(下図参照) 。 AC (GREEN) DC (WHITE) FAN1 FAN2 3.1.1 LED 表示 電源スイッチを入れると、LED が以下の通り点灯 / 点滅します。 表示色 / 状態 番号 機能 ① AC-FAIL 識別 • AC/DC 入力正常:緑点灯 • AC 入力正常 /DC 出力異常:緑点滅 • AC 入力異常 /DC 出力正常:白点灯...
  • Page 22 3.2.1 IP アドレスの再設定手順(サービス技術員用) 本機の IP アドレスが不明になった場合は、以下の手順で再設定します。 1. ネジ(M3×6)を緩め、側面のカバーを取り外します(下図参照) 。 2. ファンの下側にある工場出荷設定スイッチ(下図参照)を右側にスライド し、本機の電源をオンにすると、IP アドレスが 172.31.16.31(工場出荷値) となります。 3. LAN ケーブル(オプション)で PC と PR-851 を接続します。 4. PC のブラウザで PR-851 の WebUI を開き、[Settings]-[Network] から IP ア ドレスを再設定します(下図参照) 。 PR-851 xxx.xx.xx.xx xxx.xx.xx.xx xxxxxxx-xx.xx PR-851 xxx.xx.xx.xx xxx.xx.xx.xx...
  • Page 23 FURUNO PR-851 AC/DC 電源ユニット PR-851 仕 様 1.総合 定格入力電圧 AC100-240 V(±10%)、単相、50-60 Hz DC24 V(-10%、+30%) 定格入力電流 8.5-3.7 A(出力 30A) 定格出力電圧 DC24 V 定格出力電流 30 A(DC OUT1)、2.5 A(DC OUT2)、ただし合計 31.25 A 以下 ピーク出力電流 60 A(AC:1 分以内)、40 A(DC:1 分以内) 出力過電圧保護 出力 30~36 V で遮断...
  • Page 24 1 1 1 1 / 1 1 1 1 PACKING LIST PR-851 NAME OUTLINE DESCRIPTION/CODE No. Q’TY ユニット ユニット ユニット ユニット UNIT UNIT UNIT UNIT AC-DC 電源ユニット PR-851 AC-DC POWER SUPPLY UNIT 000-039-627-00 図書 図書 図書 図書 DOCUMENT DOCUMENT DOCUMENT DOCUMENT 装備ガイド...
  • Page 28 ・ 機器の修理・使用方法等に関するお問い合わせは、お買い上げの販売店・代理店、最寄りの   当社支店・営業所あてへお願いします。 ・ FURUNO Authorized Distributor/Dealer お問い合わせは 本書の無断複写複製(コピー)は特定の : NOV. 2023 場合を除き、当社権利侵害になります。 Printed in Japan Pub. No. C82-02201-A ( TEHI) PR-851 00019981711...