  • Page 1 Installation manual European Experts in Residential Modules » Contact us › eurener.com...
  • Page 2 3.3. Storage and handling 4. Installation design 4.1. Environmental conditions 4.2. Location 4.3. Orientation and tilt 5. Electrical installation 5.1. Series connection 5.2. Parallel connection 5.3. Grounding 6. Mechanical installation 6.1. Screw mounting 6.2. Clamp mounting 7. Cleaning and maintenance Annex eurener.com...
  • Page 3 EURENER − PHOTOVOLTAIC MODULES » 1. Introduction In this manual, the use of the word module (or modules) refers to any PV module from EURENER to be installed or handled. Standard EURENER modules are composed by the parts shown in Figure 1.
  • Page 4 EURENER’s scope and control. Therefore, exposed to light, so they must be handled with caution, EURENER does not take liability related to loss, damages especially their connectors. It is recommended to cover or costs associated to an improper use, installation or the modules with opaque material during installation.
  • Page 5 All the components used in grounding connection the modules in this way, it must be ensured that the should be of good quality, corrosion resistant and maximum system voltage is not exceeded. prepared to be outdoors. eurener.com Installation manual »...
  • Page 6 Figure 5 shows the typical procedure of screw by a professional engineer. The mounting structure mounting. system and the carried-out procedures must comply • Annex 1 shows maximum loads in EURENER modules with all the codes and regulations established by the for screw mounting. local authorities. •...
  • Page 7 Figure 7 shows the typical scheme of clamp mounting at the last module position. • Annex 2 shows maximum loads and recommended clamping areas on EURENER modules for clamp mounting on the short side. • Annex 3 shows maximum loads and recommended clamping areas on EURENER modules for clamp mounting on the long side.
  • Page 8 Corrosion on the metallization. • Objects casting shadows over the modules. • Correct torque values in screws or other fixing elements. • Check if the cables, connectors and junction boxes are in good condition. • Electrical connections. eurener.com Installation manual »...
  • Page 9 2279 1134 +5400/-2400 MEPV_Icon Plus DG Bif_550W 2279 1134 +5400/-2400 MEPV_Agro DG Bif_260-275W 1716 1128 +5400/-2400 MEPV_Agro DG Bif_325-335W 2094 1134 +5400/-2400 MEPV_Agro DG Bif_345-365W 2272 1128 +5400/-2400 MEPV_Coloured_350-365W 1722 1134 +5400/-2400 MEPV_Terracotta_360-375W 1722 1134 +5400/-2400 eurener.com Installation manual »...
  • Page 10 200 - 250 +2400/-2400 MEPV_Agro DG Bif_325-335W 2094 1134 MEPV_Agro DG Bif_345-365W 2272 1128 0 - 200 +2200/-2200 MEPV_Coloured_350-365W 1722 1134 200 - 250 +2400/-2400 0 - 200 +2200/-2200 MEPV_Terracotta_360-375W 1722 1134 200 - 250 +2400/-2400 eurener.com Installation manual »...
  • Page 11 1/4L - 1/5L +5400/-2400 MEPV_Agro DG Bif_325-335W 2094 1134 1/4L - 1/5L +5400/-2400 MEPV_Agro DG Bif_345-365W 2272 1128 1/4L - 1/5L +5400/-2400 MEPV_Coloured_350-365W 1722 1134 1/4L - 1/5L +5400/-2400 MEPV_Terracotta_360-375W 1722 1134 1/4L - 1/5L +5400/-2400 eurener.com Installation manual »...
  • Page 12 eu re ne r.co m European Experts in Residential modules contact@eurenerworld.com +34 960 045 515 Since 1997 our main purpose has been to supply quality and long-lasting photovoltaic modules that allow us and future generations, to continue Calle Colón, 1-23 46004, Valencia.