Page 2
SUITABLE GAS BURNER OPTION consumption and gas type, Natural, ULPG or LPG. SINGLE SIDED MODELS Data Plate is located under the gas burner and is 700 Low Line 700 Mk2 Pebble accessed by lifting front access panel or removing base plate.
Page 3
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Installation Before Installation N.D.E.I. system supplied with The Natural Draft Electronic Ignition (N.D.E.I.) flue required electrical fittings. Work needs to be system shall be installed by authorized personnel in undertaken by a licensed electrician if extending accordance with the manufacturer’s installation wiring.
Page 4
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces ASSEMBLY REQUIREMENTS : LOWLINE DOUBLE SIDED MODEL SHOWN DOUBLE SKIN FLUE (SIZES VARY DUE TO MODEL ) CEILING WITH 25MM AIR SPACE TO OUTER FLUE CEILING COMBUSTIBLE FRAMING WALL LININGS BY IMPORTANT: INSTALLER VENTILATION INTO...
Page 5
CONNECTION UNDER SINGLE SIDED DOUBLE SIDED BURNER SINGLE SIDED DOUBLE SIDED 700 LOW LINE 673 1000 178 700 LOW LINE 700 280 450 673 1000 250 300 850 LOW LINE 850 286 450 773 1095 250 300 850 LOW LINE...
Page 6
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Measurement and Specifications of N.D.E.I : CANTILEVER FRONT OF FIREPLACE SECTION VIEW DETAIL W - LIP TRIM ASSEMBLY * FRONT AND SIDE OF FIREPLACE TO OUTSIDE EDGE OF LIP FRAME TYPICAL ON/OFF SWITCH TO BURNER...
Page 7
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces FRAMING DIMENSIONS: LOWLINE CEILING WITH 25MM AIR SPACE TO OUTER FLUE DOUBLE SIDED DOUBLE SIDED 700 LOW LINE 1056 850 LOW LINE 1145 1100 LOW LINE 1408 1500 LOW LINE 1796...
Page 9
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces DRILL THROUGH THE BEAM , RAFTER OR FRAMING IF REQUIRED AND PUSH THROUGH THE THREADED ROD. THREADED ROD EYELET MAKE SURE THESE PLANES ARE PARALLEL, AND MAKE SURE ALL CORNERS ARE SQUARE •...
Page 10
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces AUSTRALIAN APPROVED GAS COWL APPROVED Run a bead of silicone down SECTIONS FLASHING the vertical seam of the outer casing to the flashing AUSTRALIAN APPROVED GAS COWL CEILING WITH 25MM AIR SPACE TO OUTER FLUE,REQUIRED TO SEAL CHASE APPROVED...
Page 11
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces HEAT ZONE CONVERSION CEILING WITH 25MM AIR SPACE TO OUTER FLUE SW 1 IMPORTANT: VENTILATION INTO CHASE REQUIRES 2X VENTS 480MM X 90MM (SUPPLIED) , WHEN USING THE OPTIONAL HEATBOX KITS 20 amp GPO’S Fireplace ON/OFF Switch General Purpose Outlet...
Page 12
OPTION MJ / HR MJ / HR SIZE SIZE K/PA K/PA NAT GAS NAT GAS NAT GAS SINGLE SIDED: 700 Low Line HLLC/P/L700 NAT GAS/LPG 700 Mk2 Pebble 1.85 1.00 2.35 700 Mk2 Coal 1.85 1.00 2.35 700 Ironbark Log 1.85...
Page 13
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire – Gas Installation Coal & Pebble Check unit is suitable for intended gas supply. Note position on gas appliance on drawing • Evenly spread a bag of Vermiculite into the burner specification on right hand side of appliance.
Page 14
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire – Coal & Pebble MARK 2 COALS 700/800 – 600 X 155 MARK 2 PEBBLES 700/800 – 600 X 155 MARK 2 COALS 1000 – 992 X 135 MARK 2 PEBBLES 1000 –...
Page 15
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire - 850 Ceramic Log P O S I T I O N I N G O F A L L L O G S • It is important to follow the log recommended 2 .
Page 16
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire - 850 Ceramic Log 4 . LOCATE LOG NO. 4. 6. LOCATEL O G N O. 9 . Place it on the left side of the rear log. Charred This log is placed on the log in the centre of the burner.
Page 17
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire – 700 Ceramic Log P O S I T I O N I N G OF A L L L O G S • It is important to follow the log recommended positioning.
Page 18
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire - 700 Ceramic Log 4 . LOC ATE LOG NO. 4. 6 . L O C AT E L O G N O. 7 This log is placed with the thinner edge on the The charred effect of the log is positioned on the smaller coal.
Page 19
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces User Instructions Commissioning Procedure Installed correctly the burner should not emit any 1. WARNING NOTE: Properly installed and fumes into the room. The following procedure should be operated this appliance will not leak gases. undertaken to test that the unit is operating correctly.
Page 20
Wiring Diagram Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces TAIS 00-L140-D5-000V For further service information contact Kemlan Australia Head Office –13 French Avenue, Brendale, Queensland 4500 Telephone –PH: (07) 3490 5500 08/04/2022 Ver. 28...
Page 21
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Service Instructions for Direct Ignition and Power Flue Horizon fireplaces. POWER FLUE SERVICE INSTRUCTIONS PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION PILOT WILL NOT LIGHT WITH FAN - CHECK FOR GAS SUPPLY AND TURN ON WORKING ALL CONNECTIONS 1) NO GAS...
Page 22
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces DIRECT IGNITION PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION - CHECK FOR GAS SUPPLY AND TURN ON ALL CONNECTIONS PILOT WILL NOT LIGHT 1) NO GAS - CHECK GAS PRESSURE - CHECK PILOT AND CLEAN INJECTOR - CHECK ELECTRIC SUPPLY AND TURN ON ALL SWITCHES - CHECK ALL CONNECTIONS...
Page 23
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Trouble shooting guide for Techrite ignition pack Warning: This is a 240VAC module. All connections to the module are 240V (except ignition cable and flame sense). Ensure power is switched off before checking any connection or replacing any components.
Page 24
Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Flash Code Meaning Possible Cause (Red LED) Pressure switch fail Check combustion fan. Check unit has started and pressure switch and connections. during heat cycle the Check flue for obstructions pressure switch has opened Notes: The ignition unit is polarity sensitive.
Page 25
WARRANTY FOR HORIZON MODELS Provided the appliance has been correctly installed according to instructions, Kemlan guarantee the cost of replacing parts and the labour in connection therewith for a period of 12 months from the date of installation. THIS WARRANTY DOES NOT COVER – Failure to comply with manufacturer’s operation instructions.
Need help?
Do you have a question about the 700 Low Line and is the answer not in the manual?
Questions and answers