  • Page 1 User manual Document version: V1.2.0 Product: SEMS ONE...
  • Page 2 Ampere Power Energy S.L. User Manual Revisions Version Date Description V1.0.0 09/04/2021 Initial version of document Including "Connection for managing external loads" V1.1.0 12/08/2021 Network configuration procedure in Annex V Inclusion of minimum inverter version Modified warranty period to 3 years V1.2.0 13/01/2022 Ferrite wiring explanation change...
  • Page 3 Ampere Power Energy S.L. User Manual...
  • Page 4 Description of Rx control ports Connection when working with safety voltage (24 VDC) Connection when working with alternating voltage (110/230 VAC) Start-up Configuring the SEMS ONE equipment Considerations on the default configuration Ingeteam Inverter Configuration Configuring the inverter as a slave Mobile application configuration guide...
  • Page 5 Ampere Power Energy S.L. User Manual Annex V. Network configuration...
  • Page 6 User Manual Purpose of the document This document contains a user manual for Ampere SEMS ONE. The purpose of this manual is to help the user configure and use the Ampere SEMS ONE device and all its related applications. Acronyms...
  • Page 7 User Manual General description of the product To start using Ampere SEMS ONE, you must first have a basic knowledge of the product. The peripherals available in the system and a brief description of them are below. Overview of the AMPERE SEMS ONE ●...
  • Page 8 User Manual Assembly diagram The following diagram shows a complete assembly map with a SEMS One device. This diagram shows the photovoltaic system with power inverter, as well as load control that uses a relay-contactor. It also shows the connection diagram of the communications between the components of the diagram.
  • Page 9 Ampere Power Energy S.L. User Manual List of components The SEMS ONE product is supplied with the following components inside the device packaging: Component Image x3 Wurth Ferrites 74271222 x1 ferrite key...
  • Page 10 Ampere Power Energy S.L. User Manual IEC power cable Wi-Fi antenna Wall mounting...
  • Page 11 Ampere Power Energy S.L. User Manual Wall installation manual...
  • Page 12 Ampere Power Energy S.L. User Manual Table of characteristics AMPERE SEMS ONE 2021 General Specifications Ampere SEMS ONE IP protection level IP31 Working temperature 0⁰C to 40⁰C Relative humidity 20%- 85% (non-condensing) Dimensions 243x148x66mm Weight 1.2 kg Communications port Ethernet, USB, Wi-Fi, BT, CAN and RS-485 MODBUS (x2) I/O ports (Insulated) Relay output 12V - 0.5Amax, relay output NO (x2) and relay...
  • Page 13 Ampere Power Energy S.L. User Manual Installation To install the equipment on the wall, follow these installation instructions: Steps for installing the wall-mounted unit Once the equipment has been installed on the wall, the various devices are connected and configured.
  • Page 14 User Manual Connections The Ampere SEMS ONE device needs to be connected to other devices to provide its energy monitoring capabilities and assist in making your home energy efficient. In this section you will find detailed information about the wiring of the equipment.
  • Page 15 User Manual Connection for external load management The Ampere SEMS ONE device can act on external loads using its relay outputs. Below are details on the connections for the various scenarios To avoid electrical hazards, make sure that all electrical connections are switched off...
  • Page 16 Ampere Power Energy S.L. User Manual Relays R2, R3, R4 and R5 can operate on 24 VDC safety voltage. Only if the protective cover is installed on the equipment, these relays can handle 110/230 AC voltages according to the maximum power described above. Relay protective cover Difference between equipment with and without the cover Connection when working with safety voltage (24 VDC)
  • Page 17 Ampere Power Energy S.L. User Manual Connection diagram for external loads using safety voltage Connection when working with alternating voltage (110/230 VAC) This installation is only possible if the protective cover is fitted. Remember that only relays R2, R3, R4 and R5 can be used for this purpose. To install the wiring, it is necessary to first remove the protective cover from the relay outputs.
  • Page 18 Ampere Power Energy S.L. User Manual Failure to install the protective cover causes an electric shock hazard as a voltage of 230 VAC is present on the relay outputs. It is dangerous and it is therefore the protective relay cover must be replaced after the connection has been made and before powering up these connections.
  • Page 19 Ampere Power Energy S.L. User Manual Wiring diagram for direct external loads...
  • Page 20 Ampere Power Energy S.L. User Manual Wiring diagram for external loads using a contactor...
  • Page 21 Ampere Energy's monitoring application to get up and running. The SEMS ONE device should start sending data to the Ampere Energy Cloud a few minutes after start-up. Please review the considerations below for details on the default device configuration.
  • Page 22 Ampere Power Energy S.L. User Manual Ensure that the firmware version of the inverter is higher than ABH1007_F To configure the IP we have to access the Ingecon Sun Monitor web portal and select our equipment from the available systems Systems Menu Options Once inside, select the System Configuration section.
  • Page 23 Ampere Power Energy S.L. User Manual Configuration menu In the configuration section, go to Advanced Settings. Advanced equipment configuration Select section 6 - Operation Mode Mode of operation menu Within Operation Mode set the Internal EMS Mode to Slave status Once the inverter is configured as a slave, go to section 8.2 PV Settings PV settings section...
  • Page 24 Ampere Power Energy S.L. User Manual We will have to configure the PV MPPT: Mode to Enabled Settings available in the PV section Once these changes have been made, the device must be rebooted. To do so, press the central button on the inverter until the light turns red, wait a few seconds and press the button again to switch on the inverter.
  • Page 25 Ampere Power Energy S.L. User Manual Mobile application configuration guide Add device and location The device and location must be added before the MyAmpere application can be used. Add a device and location: The device key to associate the device in the APP is on the product label on the bottom of the product (where the connection ports are located) next to the serial number (SN) From the home screen, press the menu button at the top left of the...
  • Page 26 Ampere Power Energy S.L. User Manual Make the desired changes and select "Save" Configure location settings Location settings include: ● Name Country ● ● Currency Province ● Street ● ● Contracted power Installed solar energy ● ● Information on the energy compensation tariff Information on the energy tariff...
  • Page 27 Ampere Power Energy S.L. User Manual Operating the equipment The operation mode of the equipment is based on switching the system on and off using the main power button located next to the power connector. The small button near the LED will have additional functionality in future firmware versions. Detail of part of the wiring of the equipment.
  • Page 28 RS485_2 Communications Cable Each wire must pass through its ferrite twice and the ferrite body must be as close as possible to the Ampere SEMS ONE equipment. Below is an illustration showing how the cable passes through the ferrite twice.
  • Page 29 In the first option, both devices (Ampere SEMS ONE and Ingeteam inverter) must be connected to the same router, so that both devices are on the same network. From the SEMS ONE equipment to the router using its LAN connector. From the inverter LAN port (port G) to the router (to identify the LAN port of the inverter, refer to the inverter's own manual).
  • Page 30 Ampere Power Energy S.L. User Manual Inverter connection diagram. SEMS ONE + Ingeteam ISS 1 Play TL M connected by a Switch.
  • Page 31 User Manual Annex III. Energy meter connection Before proceeding with the installation, check the energy-meter model supplied with the AMPERE SEMS ONE equipment. Carlo Gavazzi ET112 Power wiring. The phase coming from the mains (downstream of the general protections - differential and circuit breaker - of the installation) is connected to terminal 1 and the phase to the...
  • Page 32 SEMS ONE equipment. The other end is connected to the energy meter, using the terminals maintaining the colour codes and the order of the table shown:...
  • Page 33 (parallel) shown in the image. It is connected to the input assigned for the meter located at the bottom of the SEMS ONE equipment; the other end goes to the energy meter at any of the two available RJ45 inputs.
  • Page 34 User Manual Annex IV. Warranty AMPERE Energy is liable for the warranty of this product if all the installation and servicing steps described in this manual are followed in detail. Failure to comply with the installation procedures leads to automatic loss of warranty and puts the installer and user at serious risk. Refer to the...
  • Page 35 This tool enables you to select the network parameters and generate a file, AMPIConf.config, which you can upload via a USB stick to the SEMS ONE. The process is detailed below. When a Wi-Fi network has been configured, the Ethernet port will remain active with automatic DHCP addressing.
  • Page 36 Ampere Power Energy S.L. User Manual To enter the parameters, first select the network connection for the SEMS ONE (Ethernet or Wi-Fi). In both cases, the addressing type can be set to Automatic IP (for DHCP) or Static IP (to set a static IP).
  • Page 37 After putting the file in the appropriate place, remove the USB stick and insert it into one of the USB ports of the SEMS ONE. After a few seconds, the device will detect the unit and the new configuration will be automatically loaded and the network will be configured. To ensure proper loading, it is advisable to leave the unit plugged in for a couple of minutes.