Page 2
CONTENTS EU Directives and UKCA Standards......................Important Information and Health & Safety.................... Model Dimensions..............................Glass Configuration..............................Side Panel Installation............................Installation Requirements..........................Checks Before Install............................. Installation Method.............................. Side Glass Installation............................Front Glass Installation............................Log Layout................................. Remote Operation..............................Troubleshooting..............................Warranty..................................The following materials and components should be disposed of in accordance with the below table.
Page 3
Particular requirements for room heaters Particular requirements for room heaters UKCA STANDARDS All Aura Fires products are in conformity with the relevant UK Statutory Instruments All Aura Fires products are in conformity with the relevant UK Statutory Instruments (and their amendments).
Page 4
IMPORTANT INFORMATION AND HEALTH & SAFETY When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: • Read all of the instructions carefully before using the appliance, only use this appliance as described in this manual.
Page 6
CONVERTING TO GF / GF2 / GF3 The appliance is shipped in the GF3 configuration, however all models can be converted to be GF or GF2 depending on your preference. Configuration Glass Fronted A single glass panel at the front of the appliance. Configuration Glass Fronted 2 A glass panel at the front and one...
Page 7
INSTALLING THE SIDE PANELS / CONVERTING TO GF / GF2 Unscrew and remove the plaster kits from the side/s of the appliance. Screw in the side panel/s, on one or both sides. INSTRUCTION MANUAL TEMPLATE ISS. 1 INSTRUCTION MANUAL TEMPLATE ISS. 1 SINTON ISS.
Page 8
INSTALLATION REQUIREMENTS Before installing the appliance please read and take into account the following impor- tant requirements; • Consult a qualified professional to check the structure of the installation site. • These appliances have been designed to be installed into either a stud and plasterboard wall, or an existing chimney breast.
Page 9
CHECKS BEFORE INSTALLATION We recommend turning on the appliance before installation, connect the appliance to a power source using the provided electrical lead, and depress the right side of the rocker switch. Remove the electrical lead from the wall and continue with the installation. INSTRUCTION MANUAL TEMPLATE ISS.
Page 10
INSTALLATION METHOD Remove the bottom transit brackets, and side brace bars. Then screw on the top mounted brackets, and the IEC Clip on the back right. INSTRUCTION MANUAL TEMPLATE ISS. 1 INSTRUCTION MANUAL TEMPLATE ISS. 1 SINTON ISS. 1 SINTON ISS. 1...
Page 11
Screw the two top mounted brackets to the wall. You can now construct your stud wall/s around the appliance in the design of your choosing. Ensure that the appliance isn’t supporting the weight of the studwork. Do not use silicones, adhesives, or wet plaster to seal in the appliance.
Page 12
Your plasterboard can now line up with the plaster kits on the edge of the appliance. INSTRUCTION MANUAL TEMPLATE ISS. 1 INSTRUCTION MANUAL TEMPLATE ISS. 1 SINTON ISS. 1 SINTON ISS. 1...
Page 13
INSTALLING THE SIDE GLASS PANELS Unscrew and remove the top glass retainer panel. Slide in the side glass pieces. INSTRUCTION MANUAL TEMPLATE ISS. 1 INSTRUCTION MANUAL TEMPLATE ISS. 1 SINTON ISS. 1 SINTON ISS. 1...
Page 14
INSTALLING THE FRONT GLASS PANEL If using a glass sucker, apply the Suction Lifter to the glass and position the bottom edge of the glass first, then pivot the glass into the appliance. If not using a glass sucker, carefully hold the glass on either end and follow the same process. 2 people may be required for this to ensure the glass is carefully supported at all times.
Page 15
When you have your appliance installed you can set up your log set/s. There is no right or wrong way to arrange your logs, the following images are an example of how you could lay them out. SINTON 800 / 1030 SINTON 1250 / 1500 SINTON 1800 INSTRUCTION MANUAL TEMPLATE ISS.
Page 16
REMOTE OPERATION The remote handset comes pre-connected to the fireplace via Bluetooth. Simply remove the remote from its outer packaging, turn the fire to the ON position, and the remote will fully control your appliance. Please see below to identify the buttons and their functions.
Page 17
Warranty period. The Customer must inform Aura Fires in writing of the sale within 14 days of the resale. Failure to notify Aura Fires within 14 days will result in the Warranty becoming invalid. Please pass on the dated sales receipt as a proof of pur- chase to the new owner.
Page 18
WARRANTY For a Service call to be arranged Aura Fires will require proof of registration. Any Warran- ty claim without the required information will be referred back to your Retailer / Supplier from whom you purchased it. To progress any Warranty claims for damaged appliance/parts, paint or any visual de- fects, photographic or video evidence must be supplied.
Need help?
Do you have a question about the Sinton 800 and is the answer not in the manual?
Questions and answers