Download Print this page

klover BELVEDERE 30 Installation, Use, Maintenance And Helpful Tips

Advertisement

Quick Links

BELVEDERE 30
ENGLISH
wood-burning
stove
INSTALLATION, USE, MAINTENANCE
AND HELPFUL TIPS

Advertisement

loading
Need help?

Need help?

Do you have a question about the BELVEDERE 30 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for klover BELVEDERE 30

  • Page 1 BELVEDERE 30 ENGLISH wood-burning stove INSTALLATION, USE, MAINTENANCE AND HELPFUL TIPS...
  • Page 3 DoP/KLOVER-016 Identification number BV30 Model and/or lot no. and/or serial no. (Art.11-4) BELVEDERE 30 Intended use of the product according to the relevant Home heating appliance fuelled by wood pellets, harmonised technical specification which can also produce domestic hot water KLOVER s.r.l.
  • Page 4 CONTENTS CONTENTS .......................................... 1 INTRODUCTION ......................................... 3 .................................. 3 MPORTANT SAFETY INSTRUCTIONS THE APPLIANCEAND WOOD ..................................4 ..................................4 OMPONENTS OF THE APPLIANCE ...................................... 6 VERALL DIMENSIONS ....................................7 ONNECTIONS DATA SHEET .................................... 8 ECHNICAL PECIFICATIONS ....................................... 8 YPES OF WOOD REQUIREMENTS OF THE PLACE OF INSTALLATION ..........................
  • Page 5 EN - Rev. 2.0 Dear client, First of all we would like to thank you for choosing a “KLOVER” product and we hope you will be satisfied with this product. Please carefully read the warranty certificate on the last page of this User guide.
  • Page 6 - This user guide constitutes an integral part of the appliance. If the appliance is sold to another user, this manual must be passed on to the new owner. KLOVER S.R.L. DECLINES ALL LIABILITY IN CASE OF ACCIDENTS DUE TO FAILURE TO COMPLY WITH THE SPECIFICATIONS OF THIS MANUAL.
  • Page 7 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 KLOVER S.R.L. DECLINES ALL LIABILITY DUE TO INCORRECT USE OF THE APPLIANCE BY THE USER, UNAUTHORISED MODIFICATION AND/OR REPAIRS, AND USE OF NON-ORIGINAL SPARE PARTS OR SPARE PARTS NOT SPECIFICALLY DESIGNED FOR USE ON THIS APPLIANCE MODEL.
  • Page 8 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 FLUE GAS OUTLET MAJOLICA CONTROL UNIT MAJOLICA SIDE MAJOLICA FRONT WOOD LOADING DOOR WITH CERAMIC GLASS ASH DRAWER FITTINGS INSPECTION PORT...
  • Page 9 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 Overall dimensions...
  • Page 10 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 Connections data sheet REAR VIEW Description of connections M = System Delivery 3/4" F R = System Return 3/4" F F = Domestic cold water inlet (on prepared models only) and boiler unit and system load...
  • Page 11 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 Technical Specifications Nominal thermal output kW (Kcal/h) 30.6 (26,300) Nominal power released to heating water kW (Kcal/h) 27.3 (23,500) Nominal power delivered to room due to radiation kW (Kcal/h) 3.3 (2,800) Efficiency at thermal nominal power 74.34...
  • Page 12 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 Resinous woods generate a lot of soot and require the flue and the appliance to be cleaned more frequently. The calorific value of different types of wood depends greatly on their humidity and consequently the power of the appliance is directly affected by the type of wood used, on average a well-seasoned wood has a calorific value of 3200 kcal/kg.
  • Page 13 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 REQUIREMENTS OF THE PLACE OF INSTALLATION Positioning The initial phase for best installation of the appliance is to determine its optimum location; the following elements need to be considered: - The possibility of creating an external air vent;...
  • Page 14 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 External air intake During operation, the appliance takes in air from the environment in which it is installed; It is therefore essential that this air is replaced through an external air vent. The absence of the air vent may affect the flue draught and therefore the combustion and the safety of the appliance.
  • Page 15 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 - The flue gas conduits must be assembled in such a way as to guarantee adequate sealing of flue gases during low pressure operation of the appliance; - The installation of horizontal sections is prohibited;...
  • Page 16 Connection to the mains power supply should only be carried out after the wires have been connected to the terminal board. KLOVER srl declines all responsibility for injury to persons and animals or damage to objects due to failure to connect the appliance to earth or to comply with IEC specifications.
  • Page 17 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 DESCRIPTION OF THE KEYS - P1 ON/OFF This button, when pressed for two consecutive seconds, switches the control unit on/off, depending on whether it is off or on to start with. During normal operation of the appliance, the control unit must ALWAYS be switched on.
  • Page 18 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 - L6 DHW LED This LED flashes when the DHW function is being set. The LED is lit when the DHW function is on. - L7 SERV LED The LED lights up when the service thermostat is selected (for additional pump).
  • Page 19 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 - PUMP ANTI-LOCKING programme: In the event of inactivity of the PUMP outlet for longer than the ANTILOCKING Timer, this activates the outlet of the PUMP. The associated L1 LED turns on and bLP appears on the display.
  • Page 20 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 FAULT SIGNALLING AND ALARMS The control unit signals faults associated with the H2O PROBE via a flashing message: - Lo: indicates a value below the set scale (temperature below 0°C). Occurs when the H2O PROBE is off.
  • Page 21 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 Control of any coupled boiler If the wood-burning appliance is to be coupled to a previously installed boiler in the system (e.g. wall-hung gas boiler), the latter can be switched on and off via the AUX thermostat in the control unit. The coupled boiler will switch on/off once it has reached the temperature set on the AUX thermostat.
  • Page 22 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 Example of electrical connection - LINE: Connect terminals 1 and 2 to the electrical power supply (terminals already connected to power supply cable in the factory). - AUX: This is used to control a boiler coupled with the heating system where present. Connect terminals 4 and 5 (or 3 and 4 depending on the type of connection to the coupled boiler) to the RT.
  • Page 23 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 - PROBE: Connect the water temperature probe to terminals 18 and 19. This is to monitor the temperature of the water inside the appliance. If the probe is not connected, the control unit's display shows “Lo”; if there is a short- circuit in the probe, the display shows “Hi”.
  • Page 24 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 Boiling discharge Hot water outlet System delivery Cold water intake System return You can now reach the fittings from the interior of the combustion chamber. Replace the cast iron grille, taking care not to install it upside down, otherwise the ash will tend to compact in place without falling into the ash drawer.
  • Page 25 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 In the event of water with hardness exceeding 28 °f, an anti-limescale device must be installed. This must be selected on the basis of the specific properties of the water. TO AVOID COMPROMISING THE FUNCTION AND LIFE OF THE HEAT PUMP, INSTALLATION OF A FILTER AND A MAGNETIC DIRT SEPARATOR IS REQUIRED DOWNSTREAM OF THE RETURN PIPE ON THE APPLIANCE.
  • Page 26 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 Antifreeze protection In intensely cold periods it is good practice to leave the heating system running. In the event of a prolonged absence, antifreeze must be added to the heating water and to the water in the boiler unit. For the choice of antifreeze and the quantity to add to the boiler unit, see section "Maintenance of the boiler unit"...
  • Page 27 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 Warning: during the ignition phase and normal operation of the appliance, maintain the necessary safety distance and do not stand in front of it. Operation To avoid possible damage and/or deformation to the appliance, it is essential not to load excessive amounts of fuel. It is also recommended to burn only good quality, dry and well-seasoned wood (cut at least 2 years ago).
  • Page 28 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 Boiling If for any reason (power cut, pump fault, too much fuel, etc.…), the water in the boiler unit reaches boiling point, carry out the following operations immediately: - Fully open all smoke dampers;...
  • Page 29 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 What happens if there is... - INSUFFICIENT DRAUGHT - DIFFICULT FLUE GAS EVACUATION - FLUE GAS ESCAPING INTO THE ROOM ELEMENTS TO CHECK ORIGIN External air intake - Non-existent; - Shutter closed;...
  • Page 30 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0 CLEANING AND MAINTENANCE Precautions before cleaning Before carrying out any cleaning or maintenance operations, make sure that: - the appliance is off and has cooled down completely; - the ash is completely cold.
  • Page 31 You must periodically check the seals because the latter guarantee the air- and water-tightness of the appliance and its good functioning; if they are worn or damaged you need to replace them immediately by contacting a Klover Authorised technical assistance centre.
  • Page 32 ATTENTION!!! NON-USE AND OR AN INCORRECT DOSAGE OF LONG LIFE WILL INVALIDATE THE WARRANTY ON THE BOILER UNIT. LONG LIFE gas been designed and tested on SICURO TOP products; KLOVER declines all liability arising from the use of LONG LIFE in products or applications other than those indicated.
  • Page 33 The Klover Warranty will remain in effect for a period of 2 years from the date of purchase, if proven by a delivery note or other proof of purchase (e.g. receipt), stating the name of the seller, the product that was bought, and the date of purchase.
  • Page 34 Klover Products must undergo functional testing before any related masonry works are carried out (for example before tiling, installation of pilasters, or painting of the walls). Klover Srl is not liable for any costs incurred as a result of removal and/or reconstruction of related installations, or for any other ancillary intervention even if it is the result of works to replace defective parts.
  • Page 35 BELVEDERE 30 WOOD-BURNING STOVE EN - Rev. 2.0...
  • Page 36 Cod. CS.IST.BV30-EN KLOVER Srl Via A. Volta, 8 37047 San Bonifacio (VR) VAT No. 02324280235 www.klover.it...