Do you have a question about the E PC B0503 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for ECKELMANN E PC B0503
Page 1
OPERATION AND MONITORING Eckelmann industrial PC (E°PC) Quick Start Guide IMPORTANT! READ CAREFULLY BEFORE USE! KEEP FOR FUTURE REFERENCE!
Page 2
Many of the product designations used in this guide are registered trademarks of their respective owners, even if this is not explicitly indicated. Eckelmann FCS does not accept liability for their free availability and use author- isation.
Page 3
CHANGE LOG Version Chapter Date Editor Changes November 2022 A. van den Brink-Litschel Document created 3.5.3 June 2023 A. van den Brink-Litschel E°PC G0421 modified E°PC G0421 modified, E°PC C0715 added, E°PC 3.3, 3.4 Dezember 2023 A. van den Brink-Litschel C0515/C0615 removed 1.1, 3.1, 3.5, Added: E°PC G0515E, G0518E, G0521E;...
Page 5
TABLE OF CONTENTS 1 About this Guide 1.1 About the product 1.1.1 Manufacturer and product designation 1.1.2 Performance specification 1.2 Contents of this guide 1.3 Target audience 1.4 Disclaimer of liability 1.5 Conventions 1.6 Explanation of warning statements 1.6.1 Structure 1.6.2 Warning signs 2 Safety information and precautions 2.1 Intended use and operating conditions 2.1.1 Intended use...
Page 7
4.3 E°PC B0503 4.3.1 Dimensions 4.3.2 Technical data 5 Assembly and Installation 5.1 Installation 5.1.1 Control cabinet mounting (E°PC B0xxx) 5.1.2 Mounting (E°PC C0xxx/G0xxx) 5.1.3 Assembly 5.2 Connection and operation of a display and control unit (E°PC B0xxx) 5.3 Power supply 6 Commissioning 6.1 Switching on the IPC 6.1.1 Ex-works configuration...
Page 9
1 About this Guide 1.1 About the product 1.1.1 Manufacturer and product designation Manufacturer: Eckelmann FCS GmbH Designation: E°PC: E°PC B0xxx (box PC), E°PC C0xxx/G0xxx (panel PC) This guide applies to all E°PC devices built from 2024 onwards. Type plate: The type plate of the respective unit is located, together with the interface overview, on the right-hand side of the housing (E°PC B0xxx) or under the rear housing cover (E°PC C0xxx/G0xxx)
Page 10
1.4 Disclaimer of liability In order to handle and operate Eckelmann industrial PCs safely and without failure, it is necessary to adhere strictly to the information given in this document and adequately train all personnel. The man- ufacturer accepts no liability for any damage resulting from disregard of this information or employ- ment of untrained personnel.
Page 11
1.5 Conventions This document uses the following conventions and symbols: Notes that are particularly relevant and useful are highlighted as follows: N O T E Here you find a piece of information that is particularly helpful to achieve optimum use of the device.
Page 13
1.6.2 Warning signs This guide uses the following warning signs: Pictogram Type of hazard Consequences Ignoring this warning may lead to personal damage (up to and including General hazard severe injuries or death). Data loss Ignoring this warning may lead to data loss. Ignoring this warning may cause destruction of electronic components in the Damage to electronic parts device.
Page 15
Eckelmann industrial PCs are designed for operation in an industrial environment and for use in indus- trial automation systems. Eckelmann industrial PCs are built according to the current state of the art and are safe to operate when used as intended.
Page 17
2.2 Personnel qualification requirements Special expertise is required for project planning, programming, installation, commissioning and main- tenance work. This work may only be carried out by trained or specially trained personnel. The installation, commissioning and maintenance personnel must have training that authorises them to intervene on the installation and the automation system.
Page 19
It is imperative that you also take into account the safety requirements of the machine manufacturer! The manufacturer of a machine or system in which Eckelmann industrial PCs are used must prepare a hazard analysis and consequently take measures to ensure safe operation of the entire system.
Page 21
3 Panel PC: Technical Data 3.1 General information (panel PCs) Robust industrial panel PCs in a sheet steel housing Single- or multi-touch screens Platform concept: one mainboard for different sizes (construction and screen) versions with additional operating elements, second screen, ... build-in units and options for VESA mounting Abb.
Page 25
3.2.3 Technical data Electrical connection Supply voltage 24 V DC Permitted tolerance of input voltage 18 … 30 V DC Power consumption (max.) 100 W Operation Display 15“ TFT, LED backlight Resolution 1024 x 768 Touch Single touch, analog resistive (optional) Mouse/keyboard via PS/2 or USB Mainboard...
Page 27
3.3.3 Technical data Electrical connection Supply voltage 24 V DC Permitted tolerance of input voltage 18 … 30 V DC Power consumption (max.) 100 W Operation Display 21.5“ TFT, LED backlight Resolution 1920 x 1080 Mouse/keyboard via PS/2 or USB Mainboard Type Mini ITX...
Page 29
3.4.3 Technical data Electrical connection Supply voltage 24 V DC Permitted tolerance of input voltage 20 … 30 V DC Power consumption (max.) 160 W Operation Display 2 x 21.5“ TFT, LED backlight Resolution 1920 x 1080 Touch Capacitive multi-touch with up to 10 touch-points Mouse/keyboard via PS/2 or USB Mainboard...
Page 31
All dimensions indicated in mm 3.5.2 Technical data Electrical connection Supply voltage 24 V DC Permitted tolerance of input voltage 18 … 30 V DC Power consumption (max.) 100 W Operation Display 15.6 ” TFT, LED backlight Resolution 1366 x 768 Touch Multi-touch Mainboard...
Page 33
3.6.2 Technical data Electrical connection Supply voltage 24 V DC Permitted tolerance of input voltage 18 … 30 V DC Power consumption (max.) 100 W Operation Display 18.5 ” TFT, LED backlight Resolution 1366 x 768 Touch Multi-touch Mainboard Type Mini ITX Bus system PCIe...
Page 35
3.7.2 Technical data Electrical connection Supply voltage 24 V DC Permitted tolerance of input voltage 18 … 30 V DC Power consumption (max.) 120 W Operation Display 21.5 ” TFT, LED backlight Resolution 1920 x 1080 Touch Multi-touch Mainboard Type Mini ITX Bus system PCIe...
Page 39
4.2.3 Technical data Electrical connection Supply voltage 24 V DC Permitted tolerance of input voltage 18 … 30 V DC Power consumption (max.) 100 W Mainboard Type Mini ITX Bus system PCIe Chip set Intel® Q170 Main unit Intel® CoreTM i3/i5/i7 or Celeron®, 9 gen.
Page 41
4.3.2 Technical data Electrical connection Supply voltage 24 V DC Permitted tolerance of input voltage 18 … 30 V DC Power consumption (max.) 100 W Mainboard Type Mini ITX Bus system PCIe Chip set Intel® Q670E Main unit Intel® Core i3/i5/i7 or Celeron®, 13 gen.
Page 42
5 Assembly and Installation 5.1 Installation 5.1.1 Control cabinet mounting (E°PC B0xxx) Due to its compact installation dimensions, the E°PC B0xxx is particularly well suited for mounting in a control cabinet or in a suitable console housing. The protection class is IP 20. N O T I C E Overheating of the electronics due to incorrect installation Operational failure or loss of data...
Page 44
N O T I C E Overheating of the electronics due to incorrect installation Operational failure or loss of data Make sure that the air circulation inside the control cabinet is not blocked by the installation method. The ventilation slots must not be covered under any circumstances! Pay attention to the permissible working temperature range for the E°PC C0xxx/G0xxx.
Page 46
This can be operated via a standard cable connection (DVI and USB, max. cable length 3 m). If your application requires a connection over greater distances (up to max. 30 m), special extender solutions are available for this purpose. In this case, please contact Eckelmann FCS (Service-FCS@eckelmann.de oder info-fcs@eckelmann.de...
Page 47
Assembly and Installation 5.3 Power supply The Eckelmann industrial PC requires a supply voltage of 24 V DC. The permissible range of input voltage for the respective devices can be found in this guide, in the chapters on the individual IPC series.
Page 48
6 Commissioning 6.1 Switching on the IPC 6.1.1 Ex-works configuration Unless otherwise requested by the customer, the Eckelmann industrial PC is delivered with the oper- ating system Windows 10 completely installed. Your E°PC is therefore immediately ready for operation. Ex works, the integrated hard disk is divided into a primary partition (C:) and an extended partition (D:).
Page 49
Commissioning 6.2 Application for machine control An Eckelmann industrial PC is not intended for use as a stand-alone machine controller, but as a user interface (operation, visualization) in connection with a machine controller (e.g. Eckelmann E°EXC). For information on a wide range of Eckelmann machine controllers, see Eckelmann E°EDP:...
Page 50
Only trained and authorised personnel are permitted to disassemble the device. When disassembling the device, follow the same safety instructions as during maintenance. 7.2 Disposal Eckelmann FCS exclusively delivers components for machine equipment. We do not carry out measures for recovery or municipal waste management. N O T E...
Need help?
Do you have a question about the E PC B0503 and is the answer not in the manual?
Questions and answers