1
HOW TO USE THE MANUAL
2
DESCRIPTION OF THE CENTRAL VACUUM CLEANER
3
TECHNICAL DATA
4
CONSTRUCTION CHARACTERISTICS
4.1 R-EVOLUTION kit mod. 150/250 with bag suction and service suction socket 9
4.2 R-EVOLUTION kit mod. 150/250 with cyclonic suction
4.3 R-EVOLUTION kit mod.350/450 with bag suction and service suction socket
4.4 R-EVOLUTION kit mod.350/450 with cyclonic suction
5
SAFETY FEATURES
5.1 IP protection degree
5.2 Electrical insulation degree
5.3 Declaration of absence of dangerous substances
5.4 Fixed closure guards safety
5.5 Movable closure guards safety
5.6 Identifi cation plate
6
AUTHORIZED USE OF THE VACUUM CLEANER
7
UNAUTHORIZED USE OF THE VACUUM CLEANER
8
EQUIPMENT AND ACCESSORIES
9
INSTALLATION
9.1 Preliminary operations
9.2 Place of installation
9.3 Transport and unpacking
9.4 Positioning of the vacuum cleaning unit
9.5 Transforming DX version (outlet pipes fi tted on the right) into SX version
(outlet pipes fi tted on the left)
9.6 Fixing the system to the wall
9.7 Types of connection of dust collection couplings
9.7.1 Connection to the pipe network (cyclonic suction)
9.7.2 Connection to the pipe network (bag suction)
9.7.3 Connection to the service suction socket (cyclonic suction)
18/03/13 Rev:2.0.0
INSTRUCTION MANUAL
• Type: domestic vacuum cleaner
• Model: Tecno R-EVOLUTION
• Revision 2.0.0
4
4
6
8
10
11
12
13
14
14
14
14
15
15
16
16
17
19
19
19
20
21
21
23
24
25
26
27
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the R-EVOLUTION Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Tecno R-EVOLUTION Series

  • Page 1 INSTRUCTION MANUAL • Type: domestic vacuum cleaner TECNO R-EVOLUTION • Model: Tecno R-EVOLUTION Line • Revision 2.0.0 INDEX HOW TO USE THE MANUAL DESCRIPTION OF THE CENTRAL VACUUM CLEANER TECHNICAL DATA CONSTRUCTION CHARACTERISTICS 4.1 R-EVOLUTION kit mod. 150/250 with bag suction and service suction socket 9 4.2 R-EVOLUTION kit mod.
  • Page 2 ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS INSTRUCTION MANUAL TECNO R-EVOLUTION • Type: domestic vacuum cleaner • Model: Tecno R-EVOLUTION Line • Revision 2.0.0 INDEX 10 STARTING THE VACUUM CLEANER 10.1 Control board 10.2 Electrical connection 10.2.1 AUXILIARY CONNECTION SIGNAL 11 USE OF THE VACUUM CLEANER 11.1 Switching on the vacuum cleaner...
  • Page 3 TECNOPLUS S.r.l., owner of the SISTEM AIR Trademark, would fi rst of all like to thank you for having chosen to buy the R-EVOLUTION, the new Tecno-Line vacuum cleaner. We are sure that the characte- ristics described in this manual will satisfy your needs.
  • Page 4 The units of the TECNO REVOLUTION domestic line represent the most advan- ced system among vacuum cleaners for domestic use.
  • Page 5 Remember that all confi gurations of the Tecno R-EVOLUTION vacuum cleaner, can be obtained with any electrical power supply size, either with single or double suction motor.
  • Page 6 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS 3- TECHNICAL DATA Tecno R-evolution Model Sound-absorbing dome Printed Circuit Board ( = mod. 150/250; = mod. 350/450) Printed Circuit Board holding panel Start switch Air venting Motor group Switch-on signal cable (Micro line)
  • Page 7 TECNO R-evolution Tecno Tecno Tecno Tecno R-evolution 150 R-evolution 250 R-evolution 350 R-evolution 450 Model Item 3110.2T 3112.2T 3113.2T 3115.2T Computer maintenance Suction coupling Ø mm IP Protection Degree Power supply V ac 220/240 220/240 220/240 220/240 Frequency 50/60 50/60...
  • Page 8 CENTRAL VACUUM SYSTEMS 4 - CONSTRUCTION CHARACTERISTICS For one-phase vacuum cleaners for the domestic sector of the TECNO R-EVOLUTION Line, it is pos- sible to choose among four different motor types depending on the surface to be cleaned, as shown in the table below: Max.
  • Page 9 4.1 R-EVOLUTION kit mod. 150/250 with bag suction Cover Sound-absorbing dome Operator interface display control board Air venting Membrane keyboard Motor group Fixing plate Filter cartridge Cyclonic suction dust inlet Basic seal kit Aesthetic frame for elbow connector Cylinder motor body Dust bag Ring seal with gasket...
  • Page 10 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS 4.2 R-EVOLUTION kit mod. 150/250 with cyclonic suction and service suction socket Cover Sound-absorbing dome Motor group Air venting Fixing plate Operator interface display Cyclonic suction control board dust inlet Membrane...
  • Page 11 4.3 R-EVOLUTION kit mod.350/450 with bag suction Cover Sound-absorbing dome Air venting Operator interface display control board Motor group Membrane keyboard Fixing plate Cone fi lter cartridge Cyclonic suction dust inlet Basic seal kit Cylinder motor body Aesthetic frame for elbow connector Radial seal with gasket...
  • Page 12 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS 4.4 R-EVOLUTION kit mod.350/450 with cyclonic suction and service suction socket Cover Sound-absorbing dome Air venting Cone fi lter cartridge Membrane keyboard Motor group Fixing plate Cyclonic suction Operator interface dust inlet...
  • Page 13 5 SAFETY FEATURES In compliance with safety regulations detailed in the Machinery Directive 2006/42/CE (transposed into the Italian Legislation by Decree Law 17/10), in the Low Voltage Directive 2006/95/CE, and in the Electromagnetic Compatibility Directive 2004/108/CE, the R-EVOLUTION system complies with the standard established for electrical appliances for household and similar purposes EN 60335-1 (2008) and with the Regulation C EN 60335-2-2 (2011), specially conceived for vacuum cleaners for household and similar purposes with rated voltage not exceeding 250 V.
  • Page 14 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS WARNING: TECNOPLUS S.R.L. declines any form of responsibility or guarantee if the purchaser, or anyone in his stead, makes even the slightest modifi cation or adjustment to the purchased product. The unit has been designed to satisfy at best the present needs of the domestic central vacuum clea- ners market, both in terms of quality and operating capacity.
  • Page 15 5.5 Movable closure guards safety There are no movable closure guards assembled on the appliance. Every guard assembled is conside- red a fi xed guard and is fastened with special screws. TECNOPLUS s.r.l. reminds you that it is absolu- tely forbidden to replace the screws used for the design and manufacture the appliances with screws that feature different characteristics.
  • Page 16 CENTRAL VACUUM SYSTEMS 6 - AUTHORIZED USE OF THE VACUUM CLEANER The TECNO R-EVOLUTION vacuum cleaner has been designed exclusively to vacuum clean house dust, very small-size solids and dry materials. The use of the central vacuum cleaner is authorized for household and civil uses, connected to a PVC wall-traced piping network and to a standard home electrical wiring.
  • Page 17 The production confi guration of the Tecno R-EVOLUTION system features a hole to be completed with the BI-VAC kit when installing the unit. This equipment offers the following two options: - confi...
  • Page 18 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS The packaging of the vacuum cleaner also includes a series of accessories as listed below: N°1 metal bracket to fi x the system to the wall N°2 rubber sleeves for the connection to the suction pipe network N°4 metal clamps to fi...
  • Page 19 9 - INSTALLATION - WARNING - THESE PROCEDURES MUST BE CARRIED OUT BY QUALIFIED PERSONNEL 9.1 Preliminary operations The suction system is shipped to the customer completely assembled and packed Before switching the machine on, the following checks are advisable: •...
  • Page 20 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS 9.3 Transport and unpacking For transport and handling always maintain the system inside its own packaging until it reaches the place of installation. If necessary, use a fork-lift truck or ask someone to help you.
  • Page 21 9.4 Positioning of the vacuum cleaning unit For a correct use and to facilitate maintenance it is advisable to keep a minimum distance of 60 cm on three sides around the appliance (excluding the side on which it is fi xed to the wall). 9.5 Transforming DX version (outlet pipes fi...
  • Page 22 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS Remove the plate, remove the screws underneath and remove the front panel. Replace the panel on the oppo- site side. Replace the upper dome, position the electric cable in the special grooves...
  • Page 23 To do this follow the instructions detailed below: Trace the drilling position using the template provided (drilling template); if this has already been done, proceed to the next step. Height from the ground is detailed in the table below: TECNO R-evolution Tecno Tecno Tecno Tecno...
  • Page 24 fi ts into the fi xing plate. 9.7 Types of connection of dust collection couplings The TECNO R-EVOLUTION vacuum cleaner offers the Customer the possibility to choose the desired confi guration, depending on the suction cleaning desired: • confi guration 1 cyclonic bagless vacuum cleaning •...
  • Page 25 9.7.1 Connection to the piping network (cyclonic suction see pages 10-12) 1. Using the sleeve, connect the dust inlet coupling of the cyclonic vacuum cleaner, identifi ed with (A) in the picture, to the suction pipe from the piping network. 2.
  • Page 26 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS 9.7.2 Connection to the piping network (bag suction see pages 9-11) 1. If the service suction inlet is already assembled on the body of the appliance remove it being careful not to damage the inserted gasket.
  • Page 27 9.7.3 Connection to the service suction socket (cyclonic suction) 1. After lifting the closing cover, insert directly, if needed, the fl exible hose (G) in the service suction inlet (D), identifi ed in the drawing 10 STARTING THE VACUUM CLEANER 10.1 Control board The R-EVOLUTION vacuum cleaner features a control board from which the appliance functions can be programmed by means of a simple operator’s interface display with 6 function keys.
  • Page 28 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS 10.2 Electrical connection WARNING: the electrical connection must be carried out ONLY by qualifi ed personnel. Before connecting the system to the electrical power supply check that the supply voltage corresponds to that required by the vacuum cleaner (see the identifi...
  • Page 29 10.2.1 Auxiliary connection signal Example of connection of the auxiliary contact, normally open, which closes in case of alarms on the display. Ext. supply 220Vac / 12Vdc Led indicator or 12V light 18/03/13 Rev:2.0.0...
  • Page 30 The specifi cally-designed electronics applied to Tecno R-EVOLUTION vacuum cleaners is based on a so- phisticated software designed exclusively for Sistem Air, which alerts the operator, by means of a dedicated messaging package, when routine maintenance should be carried out.
  • Page 31 11.3 Programming and use of the computer for controlling the central unit The Tecno R-Evolution vacuum cleaner is provided with a practical display with membrane keyboard as shown below. The use of this display and the membrane keyboard allows the operator sending the inputs to the com- puter of the central unit in order to select the various functions, programme the routine maintenance and upload specifi...
  • Page 32 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS 11.3.1 Programming the start up Here are the main Menu screens for the start-up Screen display which appears when fi rst switching the system. Press Esc to go to the next screen.
  • Page 33 INFO INSTALLER On this screen you will be able to save some information about the installation. Write the telephone number by pressing the Up, Down, Left and Right arrows. Press Esc to confi rm the changes and go ▲ * * * * * * * * * * to the next screen.
  • Page 34 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS Alarms Below you will fi nd the screens relating to the alarms which may appear on the display. Press RESET to cancel the alarm and restore the suction if you activated the “Suction stop” option (see par.
  • Page 35 SETTINGS Press the Up and Down arrows to scroll in the menu. Press Enter to access the selected sub- Menu menu. Setup Press Esc to exit. 11.4 Menu In this menu there’s the possibility to modify the default parameters and to visualize the product infor- mation.
  • Page 36 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS 11.4.3 Maintenance menu In this menu you can fi nd all information regarding the fi lter effi ciency, the level of dust in the dust container (bin) or in the in the Bi-Vac bag, the time to the next extraordinary maintenance operations level 1 (Service 1) and 2 (Service 2).
  • Page 37 INFO INSTALLER ▲ * * * * * * * * * * ▼ Press the Up, Down, Right and Left ar- rows to put the telephone number in. Press Esc to confi rm the change and exit INFO SERVICE the menu.
  • Page 38 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS 11.4.5 Menu date and time In this menu you can modify the date and time. Set the date and time using the Up, DATE/TIME Down, Left and Right arrows. Press Esc to confi rm the modifi cation ▲...
  • Page 39 11.5.2 Set up dust collection In this menu you can modify the kind of dust collection (dust bin or bag) used by the central vacuum unit. DUST COLLECTION Press the Right and Left arrows to select the kind of dust collection and press En- ter the activate the chosen function.
  • Page 40 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS PARAMETERS Press the Up and Down arrows to select the parameter. Display stand by Press the Left and Right arrows to mo- <005> min dify the parameter. Press Esc to confi rm the modifi cation and exit the menu.
  • Page 41 11.5.4 Set up reset parameters In this menu you can reset all changes made on the parameters. By activating this function all parameters will be brought back to the default values. RESET PARAMETERS Press ENTER to activate the function. This way it is possible to restore all chan- ges made to the default settings.
  • Page 42 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS 12 - MAINTENANCE BEFORE CARRYING OUT ANY MAINTENANCE OPERATION, IT IS MANDATORY TO UNPLUG THE POWER SUPPLY CABLE FROM THE POWER SUPPLY SOCKET. PROTECTIVE MASK AND GLOVES MUST ABSOLUTELY BE WORN 12.1 Programmed routine maintenance...
  • Page 43 Level 2 • check of the wear of the suction motor carbons • replacement of the suction motor carbons • everything indicated in level 1 Also in this case the user can decide whether to stop the suction and perform the maintenance operations or to go on with the vacuuming activities and fi...
  • Page 44 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS Put the conveyor cone back in position Reassemble the dust bin inside its housing under the suction system and lock the closing handles. Switch the suction system on by pressing the ON/OFF switch.
  • Page 45 Introduce a new dust bag Reassemble the dust container in its housing under the vacuum cleaner and close it again. Switch the vacuum cleaner on by pressing the ON/OFF switch. After restarting the central vacuum unit, press RESET to cancel the alarm relating to the dust container (bag). 12.6 Dust collection, transfer and disposal Where a separated refuse collection policy is in place, once removed from the vacuum cleaner, the dust collected in dust bins and dust bags must be placed in the green “dry, non-recyclable waste”...
  • Page 46 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS 13 - REPAIRS AND SPARE PARTS 13.1 Intervention criteria Any intervention on the vacuum cleaner for repairs and/or maintenance which are not expressly authori- zed in this manual is absolutely forbidden.
  • Page 47 17 - TROUBLE SHOOTING PROBLEM CAUSE SOLUTION Alarm signalled on the display Carry out alarm RESET The power cable is unplugged Connect the power cable There is no suction from any of the The start button is on OFF Press the Start button suction sockets position The micro line cable is not...
  • Page 48 TECNO R-evolution Instruction manual ByTecnoplus s.r.l. CENTRAL VACUUM SYSTEMS PROBLEM CAUSE SOLUTION RESET the alarm and/or wait for the automatic restoration Check for a possible clogging in the piping network Check for a possible clogging in Alarm “Thermal switch” on the...